Field Notes
<--2016-11-08 11:00:00 | 2016-11-17 08:30:00-->Other sites visited today: Mayberry | Twitchell Rice | Twitchell Alfalfa | Bouldin Alfalfa
Phenocam link: Searching...
East End: 2016-11-16 10:30:00 (DOY 321)
Author: Joe Verfaillie
Others: Sam
Summary: Reinstalled computer system with network switch, reconnected sensors to CR1000.
East End 2016-11-16 I arrived about 10:30 with Sam. It was clear, sunny and cool. Very little change in the site conditions for the last few weeks. I reinstalled the Compute Stick system with the five port Ethernet switch. This allowed the connection to the LI7550 and now you can remote desktop to the compute stick with the laptop using TightVNC. However, I forgot to bring the NL115 Ethernet interface for the CR1000 so I could not connect the met data logger to the compute stick. I did reconnect the eosGP CO2 probe and conductivity sensor to the CR1000 and it seemed to continue to run. I changed the IP settings on the 7550 and the 7700. The 7550 is 192.168.2.75 and the 7700 is 192.168.2.77. I also changed the raw file interval on the 7550 from one per hour to one per half hour. This will result in the summary files having half hour averages in them. No living ants in the box here. Lots of dead ants that I tried to sweep out with a rag. The 7700 RSSI was 51. We did not clean the mirrors but brushed off some spider webs and cattail fluff. |
0 photos found
11 sets found
14 EE_met graphs found
Can't check EE_mixed
1 EE_mixed graphs found
8 EE_flux graphs found
Can't check MBWPEESWGT_mixed
1 EE_cam graphs found
Can't check MBEEWPSWEPGT_cam
Can't check SIMBTWEE_met
Can't check EE_Temp
5 EE_Temp graphs found
Can't check EE_minidot
1 EE_minidot graphs found
Can't check MBSWEEWPBCBA
1 EE_processed graphs found