Equipment and Calibration
Equipment history at Tonzi| ALL | | Anemometer || Barometer || Battery Bank || Camera || CO2 Probe || Data Logger || Forced Diffusion || Gas Analyzer || Heat Flux Plate || Infrared Temperature || Interface || LED sensor || Moisture Point || Multiplexer || Narrow Band || Net Radiometer || PAR Sensor || Precipitation || Radio || RH & Temp || Soil Moisture Probe || Soil Water Potential || Solar Controller || Solar Panel || Water Level || Weather Station |
SELECT a.recno, a.eh_date, a.eh_loc1, a.eh_loc2, IF(a.eh_loc2=:loc, a.eh_locref2, a.eh_locref1) AS ref, a.eh_locref2, a.eh_title, a.eh_notes, a.eh_id, b.serialno, b.equip, b.modelno FROM equiphist a INNER JOIN equiplist b ON a.eh_id=b.recno WHERE (a.eh_loc1=:loc1 OR a.eh_loc2=:loc2) ORDER BY b.equip, a.eh_date, field(a.eh_title,'Calibration', 'Removed', 'Installed')
Date | Serial No. | Model | Action | Ref | Notes |
---|---|---|---|---|---|
Anemometer | |||||
2015-04-08 | 0846 | 425A | Installed | Installed at 7.56m agl in a wind profile near the Floor tower. | |
2015-04-08 | 0843 | 425A | Installed | Installed at 5.42m agl in a wind profile near the Floor tower. | |
2015-04-08 | 0860 | 425A | Installed | Installed at 3.89m agl in a wind profile near the Floor tower. | |
2015-04-08 | 0839 | 425A | Installed | Installed at ~2.0m agl in a wind profile near the Floor tower. | |
2015-04-08 | 0852 | 425A | Installed | Installed at ~1.2m agl in a wind profile near the Floor tower. | |
2015-04-08 | 0854 | 425A | Installed | Installed at ~0.1m agl in a wind profile near the Floor tower. | |
2015-04-29 | 0860 | 425A | Removed | Removed from the 3.89m location on the wind profile due to bad data. This is the sonic the was banged previously. | |
2015-12-23 | 0852 | 425A | Removed | Removed from the bottom location of the wind profile near the Floor tower. | |
2015-12-23 | 0839 | 425A | Removed | Removed from the 3rd from bottom location of the wind profile near the Floor tower. | |
2015-12-23 | 0846 | 425A | Removed | Removed from the top location of the wind profile near the Floor tower. | |
2015-12-23 | 0843 | 425A | Removed | Removed from the 2nd from top location of the wind profile near the Floor tower. | |
Barometer | |||||
2018-01-15 | B0310006 | PTB101B | Installed | Installed in a box just below the 3rd lowest location of the tower co2 profile. This sensor will be used to give real time pressure to the GMP343s. | |
Battery Bank | |||||
2010-01-08 | BB-TZ_soilco2 | BB-Fab | Upgrade | I replaced both pairs of batteries in new pairs marker November 2009. | |
2010-01-27 | BB-TZ_soilco2 | BB-Fab | Maintenance | I moved and combined the east 24V system with the west 24V system. Four panels in two pairs now feed two pairs of batteries through one charge controller. | |
2017-01-17 | BB-TT | BB-Fab | Maintenance | The Tower has been losing power over night recently. All the batteries were disconnected and tested them with the load tester. Four batteries tested bad. We removed them and reconnected the others. | |
2017-07-12 | BB-TT | BB-Fab | Maintenance | I swapped out the eight batteries remaining in the Tower battery bank sn BB-TT and replaced them with twelve new Duracell deep cycle marine group 27 lead acid batteries SLI27MDC from Batteries Plus. It’s still a 12V system pending a major rewiring in the future. | |
2017-09-28 | BB-TT | BB-Fab | Upgrade | The Tonzi Tower battery bank was rewired to be a 24V system for the upgrade of the solar power system. | |
2018-06-26 | BB-TZ_soilco2 | BB-Fab | Maintenance | The top of the plates were visible in almost all cells. I refilled them all with DI water. | |
2018-12-13 | BB-TZ_soilco2 | BB-Fab | Upgrade | This system has been failing overnight partly because one set of Vaisala probes have not been cycling off. I also added to old batter most recently used on East End. | |
2019-07-16 | BB-TZ_soilco2 | BB-Fab | Maintenance | There are six batteries in three pairs for a 24V system – the original four plus two more we added last winter. Two of the originals test a little weak with the load tester so I disconnected them from the bank. | |
2019-08-22 | BB-TZ_soilco2 | BB-Fab | Upgrade | Six old weak batteries (four currently connected) were brought back to the lab and four new Duracell deep cycle flooded group 27 batteries were installed in pairs for a 24V system. The new batteries have 09/19 (Sept/2019) stickers. | |
2020-09-01 | BB-TT | BB-Fab | Maintenance | none | The batteries were bone dry, 8-9 gallons of water into the 12 batteries. 4-5 batteries on the east side of south row got purified water instead of distilled. Two western most batteries tested bad with load tester and were brought in. The rest tested good, were reconnected and powered up. |
2021-06-24 | BB-TZ_soilco2 | BB-Fab | Maintenance | Battery Bank soil co2 | Added about 1.5 gallons of DI to the four batteries in total. No plates exposed. |
2022-08-05 | BB-TZ_soilco2 | BB-Fab | Maintenance | Battery Bank soil co2 | The batteried in this bank have been temporarily removed to power the Tower. Likely this bank will be repopulated to power the OSU-SP1 system and a couple FD chambers as the Vaisala soil CO2 system is decommissioned. |
2022-08-25 | BB-TZ_soilco2 | BB-Fab | Maintenance | Battery Bank soil co2 | This battery bank had been without batteries since its batteries were moved to the Tower a few weeks ago. I installed three old batteries from the Floor system that tested ok with the load tester. I rewired the two larger solar panels to 12V. The two smaller panels had there leads chewed and I left them disconnected for now. |
2023-03-01 | BB-TZ_soilco2 | BB-Fab | Replaced | Battery Bank soil co2 | I brought the three batteries last remove from HS and put them under the solar panels. I rewired all the panels into a terminal strip. I used one of the old batteries for the fence charger and brought the rest in. |
2023-11-13 | BB-TF | BB-Fab | Upgrade | Battery Bank Floor | We removed four flooded batteries that came from the Tower. Two are probably still good. The other two seemed to be internally shorted. Four new group 27 AGM batteries were installed. |
2024-05-15 | BB-TZ_soilco2 | BB-Fab | Upgrade | Battery Bank soil co2 | I replaced the three flooded batteries in the Soil CO2 battery bank with two new SLA group 27 batteries. The cows had chewed up all the wiring. I replaced all the wires. Now only the two larger 40W panels are connect resulting in about 4.5A. The charge controller is only 6A. The new power line runs to the OSU SP1 box. |
Camera | |||||
2011-10-18 | 0030F4D0A167 | NULL | Installed | Installed on the Tonzi tower to cover the same area as the existing webcam. The camera is mounted about 20m agl and is pointing about 310deg true and 20deg down from horizontal. Horizontal FOV is about 70deg. | |
2018-06-01 | 48013741 | A325sc | Installed | Camera Thermal | Installed on a tripod near the Floor site pointing north. |
2018-07-18 | 48013741 | A325sc | Moved | Camera Thermal | The camera was moved from its tripod near the Floor site to the northwest corner on the Tower 18m agl. The camera is pointed to the north. |
2020-09-01 | 48013741 | A325sc | Removed | Camera Thermal | Removed from the Tower because it was not responding. It seemed to power up okay but its power indicator was solid red indicating an error. |
CO2 Probe | |||||
2003-02-17 | Y0850004 | GMP221 | Installed | CO2 Probe Open Profile -0.16 | Installed at Tonzi in the east open set at 16cm deep. |
2003-03-17 | Y0710013 | GMP221 | Installed | CO2 Probe Tree1 Profile -0.16 | Installed at Tonzi in the west under canopy set at 16cm deep. |
2005-02-17 | Z2720014 | GMP222 | Location | CO2 Probe Open Profile -0.02 | Location noted at Tonzi in Open (East) profile at -2cm |
2005-02-17 | Z2720011 | GMP222 | Location | CO2 Probe Open Profile -0.04 | Location noted at Tonzi in Open (East) profile at -4cm |
2005-02-17 | Z2720012 | GMP222 | Location | CO2 Probe Open Profile -0.08 | Location noted at Tonzi in Open (East) profile at -8cm |
2005-02-17 | X4840007 | GMP222 | Location | CO2 Probe Tree1 Profile -0.02 | Location noted at Tonzi in Tree 1 (West) profile at -2cm |
2005-02-17 | X1920001 | GMP222 | Location | CO2 Probe Tree1 Profile -0.08 | Location noted at Tonzi in Tree 1 (West) profile at -8cm - listed as probe #2 |
2005-02-17 | X1520002 | GMP221 | Location | CO2 Probe Tree1 Profile -0.16 | Location noted at Tonzi in Tree 1 (West) profile at -16cm - listed as probe #3 |
2005-02-17 | Y0710013 | GMP221 | Location | CO2 Probe Tree1 Profile -0.04 | Location noted at Tonzi in Tree 1 (West) profile at -4cm - listed as probe #4 |
2005-05-16 | Y0850004 | GMP221 | Removed | CO2 Probe Open Profile -0.16 | Removed from Tonzi in the east open area set at 16cm deep |
2005-05-16 | Y4110008 | GMP221 | Removed | Removed from Tonzi - location at Tonzi unknown | |
2008-03-06 | X3830001 | GMP222 | Installed | CO2 Probe Open Profile -0.02 | Installed in the East open grass profile at -2cm. mV and ppm readings in air were recorded before installation. |
2008-03-06 | X4840007 | GMP222 | Installed | CO2 Probe Open Profile -0.04 | Installed in the East open grass profile at -4cm. mV and ppm readings in air were recorded before installation. |
2008-03-06 | Z2720014 | GMP222 | Installed | CO2 Probe Open Profile -0.08 | Installed in the East open grass profile at -8cm. mV and ppm readings in air were recorded before installation. |
2008-03-06 | X1920001 | GMP222 | Installed | CO2 Probe Open Profile -0.16 | Installed in the East open grass profile at -16cm. mV and ppm readings in air were recorded before installation. |
2008-03-06 | Z2720013 | GMP222 | Installed | CO2 Probe Tree1 Profile -0.02 | Installed in the Wast under tree profile at -2cm. mV and ppm readings in air were recorded before installation. |
2008-03-06 | X5050014 | GMP222 | Installed | CO2 Probe Tree1 Profile -0.04 | Installed in the Wast under tree profile at -4cm. mV and ppm readings in air were recorded before installation. |
2008-03-06 | Z2720011 | GMP222 | Installed | CO2 Probe Tree1 Profile -0.08 | Installed in the Wast under tree profile at -8cm. mV and ppm readings in air were recorded before installation. |
2008-03-06 | Z2720012 | GMP222 | Installed | CO2 Probe Tree1 Profile -0.16 | Installed in the Wast under tree profile at -16cm. mV and ppm readings in air were recorded before installation. |
2010-01-08 | X3830001 | GMP222 | Location | CO2 Probe Tree1 Profile -0.02 | Pulled out for ambient air reading and put back. |
2010-01-08 | X4840007 | GMP222 | Location | CO2 Probe Tree1 Profile -0.04 | Pulled out for ambient air reading and put back. |
2010-01-08 | Z2720014 | GMP222 | Location | CO2 Probe Tree1 Profile -0.08 | Pulled out for ambient air reading and put back. |
2010-01-08 | X1920001 | GMP222 | Location | CO2 Probe Tree1 Profile -0.16 | Pulled out for ambient air reading and put back. |
2010-01-08 | Z2720013 | GMP222 | Location | CO2 Probe Open Profile -0.02 | Pulled out for ambient air reading and put back. |
2010-01-08 | X5050014 | GMP222 | Location | CO2 Probe Open Profile -0.04 | Pulled out for ambient air reading and put back. |
2010-01-08 | Z2720011 | GMP222 | Location | CO2 Probe Open Profile -0.08 | Pulled out for ambient air reading and put back. |
2010-01-08 | Z2720012 | GMP222 | Location | CO2 Probe Open Profile -0.16 | Pulled out for ambient air reading and put back. |
2012-02-16 | Z2720013 | GMP222 | Installed | CO2 Probe Tree1 Profile -0.02 | Installed at Tonzi in the Tree1 set at -2cm |
2012-02-16 | X5050014 | GMP222 | Installed | CO2 Probe Tree1 Profile -0.04 | Installed at Tonzi in the Tree1 set at -4cm |
2012-02-16 | Z2720011 | GMP222 | Installed | CO2 Probe Tree1 Profile -0.08 | Installed at Tonzi in the Tree1 set at -8cm |
2012-02-16 | X4840007 | GMP222 | Installed | CO2 Probe Open Profile -0.04 | Installed at Tonzi in the Open set at -4cm |
2012-02-16 | Z2720014 | GMP222 | Installed | CO2 Probe Open Profile -0.08 | Installed at Tonzi in the Open set at -8cm |
2012-02-16 | Z2720012 | GMP222 | Installed | CO2 Probe Open Profile -0.02 | Installed at Tonzi in the Open set at -2cm. This was supposed to be sn X3830001 but that probe was not working and so was returned to the lab. |
2012-03-02 | Z2720012 | GMP222 | Installed | CO2 Probe Tree2 Profile -0.02 | Installed at Tonzi in the Tree2 set at -2cm |
2012-03-02 | Y2009109 | GMP222 | Installed | CO2 Probe Tree2 Profile -0.04 | Installed at Tonzi in the Tree2 set at -4cm |
2012-03-02 | X1920001 | GMP222 | Installed | CO2 Probe Tree2 Profile -0.08 | Installed at Tonzi in the Tree2 set at -8cm |
2012-03-02 | F4960019 | GMT221 | Installed | CO2 Probe Tree2 Profile -0.02 | Installed at Tonzi in the Tree2 set at -2cm |
2014-01-24 | Z2720013 | GMP222 | Removed | CO2 Probe Tree1 Profile -0.02 | Removed from Tonzi tree #1 at -2cm for lab calibration |
2014-01-24 | X5050014 | GMP222 | Removed | CO2 Probe Tree1 Profile -0.04 | Removed from Tonzi tree #1 at -4cm for lab calibration |
2014-01-24 | Z2720011 | GMP222 | Removed | CO2 Probe Tree1 Profile -0.08 | Removed from Tonzi tree #1 at -8cm for lab calibration |
2014-01-24 | Z2720012 | GMP222 | Removed | CO2 Probe Open Profile -0.02 | Removed from Tonzi open at -2cm for lab calibration |
2014-01-24 | X4840007 | GMP222 | Removed | CO2 Probe Open Profile -0.04 | Removed from Tonzi open at -4cm for lab calibration |
2014-01-24 | Z2720014 | GMP222 | Removed | CO2 Probe Open Profile -0.08 | Removed from Tonzi open at -8cm for lab calibration |
2014-01-24 | F4960019 | GMT221 | Removed | CO2 Probe Tree2 Profile -0.02 | Removed from Tonzi tree #2 at -2cm for lab calibration |
2014-01-24 | Y2009109 | GMP222 | Removed | CO2 Probe Tree2 Profile -0.04 | Removed from Tonzi tree #2 at -4cm for lab calibration |
2014-01-24 | X1920001 | GMP222 | Removed | CO2 Probe Tree2 Profile -0.08 | Removed from Tonzi tree #2 at -8cm for lab calibration |
2014-01-29 | Z2720012 | GMP222 | Installed | CO2 Probe Open Profile -0.02 | Installed at Tonzi in the Open profile at -2cm with new U-shaped tops on the PVC enclosures |
2014-01-29 | X4840007 | GMP222 | Installed | CO2 Probe Open Profile -0.04 | Installed at Tonzi in the Open profile at -4cm with new U-shaped tops on the PVC enclosures |
2014-01-29 | F4960020 | GMT221 | Installed | CO2 Probe Open Profile -0.08 | Installed at Tonzi in the Open profile at -8cm with new U-shaped tops on the PVC enclosures |
2014-01-29 | Z2720013 | GMP222 | Installed | CO2 Probe Tree1 Profile -0.02 | Installed at Tonzi in the Tree 1 profile at -2cm with new U-shaped tops on the PVC enclosures |
2014-01-29 | X5050014 | GMP222 | Installed | CO2 Probe Tree1 Profile -0.04 | Installed at Tonzi in the Tree 1 profile at -4cm with new U-shaped tops on the PVC enclosures |
2014-01-29 | G0150036 | GMT221 | Installed | CO2 Probe Tree1 Profile -0.08 | Installed at Tonzi in the Tree 1 profile at -8cm with new U-shaped tops on the PVC enclosures |
2014-03-18 | Z2720013 | GMP222 | Moved | CO2 Probe Tree1 Profile -0.04 | At Tonzi in the Tree 1 profile this probe was moved from the -2cm location to -4cm |
2014-03-18 | X5050014 | GMP222 | Moved | CO2 Probe Tree1 Profile -0.02 | At Tonzi in the Tree 1 profile this probe was moved from the -4cm location to -2cm |
2014-03-27 | Z2720012 | GMP222 | Moved | CO2 Probe Tree2 Profile -0.04 | This probe in the Tonzi Open profile was moved from the -2cm location to the Tree2 profile -4cm |
2014-03-27 | X4840007 | GMP222 | Moved | CO2 Probe Tree2 Profile -0.02 | This probe in the Tonzi Open profile was moved from the -4cm location to the Tree2 profile -2cm |
2014-03-27 | F4960020 | GMT221 | Moved | CO2 Probe Tree2 Profile -0.08 | This probe in the Tonzi Open profile was moved from the -8cm location to the Tree2 profile -8cm |
2014-04-08 | K1310104 | GMP222 | Installed | CO2 Probe Open Profile -0.02 | Installed at Tonzi in the Open profile at -2cm. not clear if it replaced another probe. |
2014-04-08 | K1310103 | GMP222 | Installed | CO2 Probe Open Profile -0.04 | Installed at Tonzi in the Open profile at -4cm. not clear if it replaced another probe. |
2014-04-08 | K1310102 | GMP222 | Installed | CO2 Probe Open Profile -0.08 | Installed at Tonzi in the Open profile at -8cm. not clear if it replaced another probe. |
2014-12-09 | K1310102 | GMP222 | Location | CO2 Probe Open Profile -0.02 | Tonzi Open profile at -2cm |
2014-12-09 | K1310103 | GMP222 | Location | CO2 Probe Open Profile -0.04 | Tonzi Open profile at -4cm |
2014-12-09 | K1310104 | GMP222 | Location | CO2 Probe Open Profile -0.08 | Tonzi Open profile at -8cm |
2014-12-09 | X5050014 | GMP222 | Location | CO2 Probe Tree1 Profile -0.02 | Tonzi Tree1 profile at -2cm |
2014-12-09 | Z2720013 | GMP222 | Location | CO2 Probe Tree1 Profile -0.04 | Tonzi Tree1 profile at -4cm |
2014-12-09 | G0150036 | GMT221 | Location | CO2 Probe Tree1 Profile -0.08 | Tonzi Tree1 profile at -8cm |
2014-12-09 | X4840007 | GMP222 | Location | CO2 Probe Tree2 Profile -0.02 | Tonzi Tree2 profile at -2cm |
2014-12-09 | F4960020 | GMT221 | Location | CO2 Probe Tree2 Profile -0.08 | Tonzi Tree2 profile at -8cm |
2014-12-09 | Z2720012 | GMP222 | Removed | CO2 Probe Tree1 Profile -0.04 | this probe was at Tonzi Tree2 profile at -4cm, notes say it was swapped but no serial number of the new probe |
2015-11-03 | X5050014 | GMP222 | Removed | CO2 Probe Tree1 Profile -0.02 | Removed from the Tonzi Tree 1 profile at -2cm due to bad readings. Replaced by sn L2010069 |
2015-11-03 | L2010069 | GMM222 | Installed | CO2 Probe Tree1 Profile -0.02 | Installed in the Tonzi Tree 1 profile at -2cm to replace sn X5050014 |
2016-02-04 | K1310102 | GMP222 | Removed | CO2 Probe Open Profile -0.02 | Removed from Tonzi Open profile at -2cm for calibration |
2016-02-04 | K1310103 | GMP222 | Removed | CO2 Probe Open Profile -0.04 | Removed from Tonzi Open profile at -4cm for calibration |
2016-02-04 | K1310104 | GMP222 | Removed | CO2 Probe Open Profile -0.08 | Removed from Tonzi Open profile at -8cm for calibration |
2016-02-04 | L2010069 | GMM222 | Removed | CO2 Probe Tree1 Profile -0.02 | Removed from Tonzi Tree profile at -2cm for calibration |
2016-02-04 | Z2720013 | GMP222 | Removed | CO2 Probe Tree1 Profile -0.04 | Removed from Tonzi Tree profile at -4cm for calibration |
2016-02-04 | G0150036 | GMT221 | Removed | CO2 Probe Tree1 Profile -0.08 | Removed from Tonzi Tree profile at -8cm for calibration |
2016-02-04 | Z2720014 | GMP222 | Removed | CO2 Probe Tree2 Profile -0.02 | Removed from Tonzi Tree 2 profile at -2cm for calibration |
2016-02-04 | Z2720012 | GMP222 | Removed | CO2 Probe Tree2 Profile -0.04 | Removed from Tonzi Tree 2 profile at -4cm for calibration |
2016-02-04 | F4960020 | GMT221 | Removed | CO2 Probe Tree2 Profile -0.08 | Removed from Tonzi Tree 2 profile at -8cm for calibration |
2016-02-23 | K1310102 | GMP222 | Installed | CO2 Probe Open Profile -0.02 | Installed in the Tonzi Open profile at -2cm after lab calibration. |
2016-02-23 | Z2720015 | GMP222 | Installed | CO2 Probe Open Profile -0.04 | Installed in the Tonzi Open profile at -4cm after lab calibration. |
2016-02-23 | K1340006 | GMP221 | Installed | CO2 Probe Open Profile -0.08 | Installed in the Tonzi Open profile at -8cm after lab calibration. |
2016-02-23 | L2010069 | GMM222 | Installed | CO2 Probe Tree1 Profile -0.02 | Installed in the Tonzi Tree 1 profile at -2cm after lab calibration. |
2016-02-23 | G0150035 | GMT221 | Installed | CO2 Probe Tree1 Profile -0.04 | Installed in the Tonzi Tree 1 profile at -4cm after lab calibration. |
2016-02-23 | G0150036 | GMT221 | Installed | CO2 Probe Tree1 Profile -0.08 | Installed in the Tonzi Tree 1 profile at -8cm after lab calibration. |
2016-02-23 | Z2720012 | GMP222 | Installed | CO2 Probe Tree2 Profile -0.02 | Installed in the Tonzi Tree 2 profile at -2cm after lab calibration. |
2016-02-23 | K1310104 | GMP222 | Installed | CO2 Probe Tree2 Profile -0.04 | Installed in the Tonzi Tree 2 profile at -4cm after lab calibration. |
2016-02-23 | F4960020 | GMT221 | Installed | CO2 Probe Tree2 Profile -0.08 | Installed in the Tonzi Tree 2 profile at -8cm after lab calibration. |
2017-08-25 | X4840007 | GMP222 | Notes | We removed the CO2 probe at the Tree 2 profile at -2 cm position. The probe was sn Z2720014. Not sure where sn X4840007 is. | |
2017-08-25 | Z2720012 | GMP222 | Notes | Removed CO2 probe from Tonzi Tree2 profile at -2 cm. It was sn Z2720014, not sn Z2720012. Not sure where sn Z2720012 is. | |
2017-08-25 | K1310102 | GMP222 | Removed | CO2 Probe Open Profile -0.02 | Removed from Tonzi Open profile at -2 cm position for calibration |
2017-08-25 | Z2720015 | GMP222 | Removed | CO2 Probe Open Profile -0.04 | Removed from Tonzi Open profile at -4 cm position for calibration |
2017-08-25 | K1340006 | GMP221 | Removed | CO2 Probe Open Profile -0.08 | Removed from Tonzi Open profile at -8 cm position for calibration |
2017-08-25 | L2010069 | GMM222 | Removed | CO2 Probe Tree1 Profile -0.02 | Removed from Tonzi Tree 1 profile at -2 cm position for calibration |
2017-08-25 | G0150035 | GMT221 | Removed | CO2 Probe Tree1 Profile -0.04 | Removed from Tonzi Tree 1 profile at -4 or -8 cm position for calibration. Probe labeled 16. |
2017-08-25 | G0150036 | GMT221 | Removed | CO2 Probe Tree1 Profile -0.08 | Removed from Tonzi Tree 1 profile at -4 or -8 cm position for calibration. Probe labeled 8. |
2017-08-25 | K1310104 | GMP222 | Removed | CO2 Probe Tree2 Profile -0.04 | Removed from Tonzi Tree 2 profile at -4 cm position for calibration |
2017-08-25 | F4960020 | GMT221 | Removed | CO2 Probe Tree2 Profile -0.08 | Removed from Tonzi Tree 2 profile at -8 cm position for calibration |
2017-08-25 | Z2720014 | GMP222 | Removed | CO2 Probe Tree2 Profile -0.02 | Removed from Tonzi Tree 2 profile at -2 cm position for calibration |
2017-09-14 | K1310104 | GMP222 | Installed | CO2 Probe Open Profile -0.02 | Installed at Tonzi in the Open profile at -2cm after lab calibration. This is a new installation with new holes dug. |
2017-09-14 | Z2720015 | GMP222 | Installed | CO2 Probe Open Profile -0.04 | Installed at Tonzi in the Open profile at -4cm after lab calibration. This is a new installation with new holes dug. |
2017-09-14 | K1340006 | GMP221 | Installed | CO2 Probe Open Profile -0.08 | Installed at Tonzi in the Open profile at -8cm after lab calibration. This is a new installation with new holes dug. |
2017-09-14 | G0150037 | GMT221 | Installed | CO2 Probe Open Profile -0.16 | Installed at Tonzi in the Open profile at -16cm after lab calibration. This is a new installation with new holes dug. |
2017-09-14 | L2010069 | GMM222 | Installed | CO2 Probe Tree1 Profile -0.02 | Installed at Tonzi in the Tree 1 profile at -2cm after lab calibration. This is a new installation with new holes dug. |
2017-09-14 | G0150035 | GMT221 | Installed | CO2 Probe Tree1 Profile -0.04 | Installed at Tonzi in the Tree 1 profile at -4cm after lab calibration. This is a new installation with new holes dug. |
2017-09-14 | G0150036 | GMT221 | Installed | CO2 Probe Tree1 Profile -0.08 | Installed at Tonzi in the Tree 1 profile at -8cm after lab calibration. Using old tube at -8cm. |
2017-09-14 | Y2009100 | GMP221 | Installed | CO2 Probe Tree1 Profile -0.16 | Installed at Tonzi in the Tree 1 profile at -16cm after lab calibration. This is a new installation with new holes dug. |
2017-09-14 | Z2720014 | GMP222 | Installed | CO2 Probe Tree2 Profile -0.02 | Installed at Tonzi in the Tree 2 profile at -2cm after lab calibration. This is a new installation with new holes dug. |
2017-09-14 | K1350103 | GMP222 | Installed | CO2 Probe Tree2 Profile -0.04 | Installed at Tonzi in the Tree 2 profile at -4cm after lab calibration. This is a new installation with new holes dug. |
2017-09-14 | F4960020 | GMT221 | Installed | CO2 Probe Tree2 Profile -0.08 | Installed at Tonzi in the Tree 2 profile at -8cm after lab calibration. This is a new installation with new holes dug. |
2017-09-14 | Y0850004 | GMP221 | Installed | CO2 Probe Tree2 Profile -0.16 | Installed at Tonzi in the Tree 2 profile at -16cm after lab calibration. This is a new installation with new holes dug. |
2018-01-15 | N2220007 | GMP343 | Installed | Installed at the lowest location in the tower co2 profile - not running yet due to data logger failure. | |
2018-01-15 | N2210010 | GMP343 | Installed | Installed at the 2nd lowest location in the tower co2 profile - not running yet due to data logger failure. | |
2018-01-15 | N2210009 | GMP343 | Installed | Installed at the 3rd lowest location in the tower co2 profile - not running yet due to data logger failure. | |
2018-02-07 | N2220008 | GMP343 | Installed | Installed at the top location on the Tonzi Tower in the new Vaisala co2 Profile. | |
2019-11-19 | G0150037 | GMT221 | Removed | CO2 Probe Open Profile -0.16 | Removed from the deepest (-16cm) location in the Open soil co2 profile because its measurement was railed. This is a 3% probe and was replaced by a 1% probe. |
2019-11-19 | K1310102 | GMP222 | Installed | CO2 Probe Open Profile -0.16 | Installed in the deepest (-16cm) location in the Open soil co2 profile to replace a 3% probe that was railed. This is a 1% probe. |
2023-01-06 | N2220008 | GMP343 | Removed | CO2 Probe Tower Profile 23 | Removed from the top of the tower. This sensor has not been working for a while. I don't see any issues - brought in for testing. |
2024-02-09 | N2220007 | GMP343 | Removed | CO2 Probe Tower Profile 0.35 | Removed from the lowest location on the Tower due to bad readings, cow chewed cable and to be calibrated |
2024-02-09 | N2210010 | GMP343 | Removed | CO2 Probe Tower Profile 1.8 | Removed from the lower mid location on the Tower due to bad readings and to be calibrated |
2024-02-09 | N2210009 | GMP343 | Removed | CO2 Probe Tower Profile 6 | Removed from the upper mid location on the Tower due to bad readings and to be calibrated |
2024-02-27 | N2220007 | GMP343 | Installed | CO2 Probe Tower Profile 0.35 | Reinstalled in the bottom location of the Tower co2 profile after testing in the lab. New cable. |
2024-02-27 | N2210010 | GMP343 | Installed | CO2 Probe Tower Profile 1.8 | Reinstalled in the lower-mid location of the Tower co2 profile after testing in the lab. |
2024-02-27 | N2210009 | GMP343 | Installed | CO2 Probe Tower Profile 6 | Reinstalled in the upper-mid location of the Tower co2 profile after testing in the lab. |
2024-02-27 | N2220008 | GMP343 | Installed | CO2 Probe Tower Profile 23 | Reinstalled in the top location of the Tower co2 profile after testing in the lab. Reinstalled cable. |
2024-04-22 | N2210009 | GMP343 | Removed | CO2 Probe Tower Profile 6 | Not sending sensible data. Not sure why. Brought in for testing. |
2024-06-19 | N2210009 | GMP343 | Installed | CO2 Probe Tower Profile 6 | Reinstalled in location #3 (6m) of the Tower co2 profile. |
2024-10-10 | N2220007 | GMP343 | Removed | CO2 Probe Tower Profile 0.35 | Removed from the lowest position in the Tower CO2 profile. This sensor has bad CO2 readings. Occasionally restarting the sensor seemed to fix it but not this time. Need to check the data and test it in the lab. |
Data Logger | |||||
2002-06-20 | 2301 | CR23X | Installed | Data Logger Soil CO2 | Installed with the initiation of soil CO2 gradient measurements |
2010-02-10 | 38347 | CR10X | Removed | This data logger was removed from Tonzi. It was used for sap flow just west of the floor tower. AM416 sn 14049 was removed with it. Wiring panel is 28250. | |
2010-03-16 | 25799 | CR10X | Installed | This data logger was installed with new supplemental radiation and air temperature sensor inside the floor cow fense. Problems getting final storage data dumped - will have it swapped out by next visitor. | |
2010-03-19 | 20140 | CR10X | Installed | Given to Siyan to install in the supplemental solar radiation measurements near the tram and floor system. | |
2010-03-21 | 25799 | CR10X | Removed | This data logger was swapped out by Siyan from the floor supplemental radiation and temperature system. Final storage data is corrupt. | |
2010-12-09 | 20139 | CR10X | Removed | This data logger was removed with the IRT sensors from Tonzi. | |
2011-02-03 | 20140 | CR10X | Removed | Removed from Tonzi Floor. This data logger was recording up and down PAR, net and shf from the open space near the floor solar panels and net, RH and T and shf from under the trees. | |
2012-01-09 | 41907 | CR1000 | Installed | Installed in the Campbell Enclosure at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 41909 | CR1000 | Installed | Installed in the Campbell Enclosure at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 38970 | CR3000 | Installed | Installed in the Campbell Enclosure at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2013-01-06 | 12213 | CR10X | Removed | Removed from the non-functional east sap flow station at Tonzi. | |
2013-10-18 | 31308 | CR10X | Removed | The tram derailed at the far end of the track not stopping and reversing direction. Initially it reset okay moving to park, but it did not run on the hour. The data was corrupt, but I was able to upload programs and a new OS in the field. It still would not run. I brought it in for fixing. | |
2015-04-08 | 66250 | CR1000 | Installed | Installed with the Handar wind profile near the Floor tower. | |
2015-05-06 | 66249 | CR1000 | Installed | Data Logger IRT | Installed at Tonzi to the east just north of the road. This data logger is collecting data from the two IRT sensors |
2015-12-23 | 66250 | CR1000 | Removed | Removed from the box for the wind profile near the Floor tower. | |
2016-07-07 | 19481 | CR10X | Removed | Removed from the Floor soil temperature, SHF, RH&T and Pres. These sensors have been moved to the CR23x collecting soil moisture. | |
2016-10-13 | 48042 | CR10X | Removed | Removed from the non-functioning sap flow station within the Tower cow fence | |
2016-10-13 | 47772 | CR10X | Removed | Removed from the non-functioning sap flow station north of the road | |
2018-02-07 | 2113 | CR6 | Installed | Installed on Tonzi Tower for the Vaisala GMP CO2 profile. | |
2018-03-06 | 20138 | CR10X | Removed | Removed from Tonzi tower's old CO2 profile system b/c the profile system was not working. It was replaced by sn 47253. | |
2018-03-06 | 47253 | CR10X | Installed | Installed at Tonzi to try to fix the CR10x running the tower's old CO2 profile system. It replaced sn 20138. | |
2018-05-23 | 47253 | CR10X | Removed | Removed from the Tonzi Tower with the old CO2 profile system. New Vaisala profile system is running | |
2019-01-13 | 20138 | CR10X | Installed | Installed near the Floor solar panels to record temperatures from a concrete cal panel for the FLIR thermal camera. | |
2019-04-16 | 47772 | CR10X | Removed | Removed with the wooden cal panel for the FLIR because cows chewed the TC wires and the new cal panel is better | |
2019-05-30 | 47772 | CR10X | Installed | Installed near an oak tree about 25m north of the Floor solar panels to support two IRTs | |
2020-03-02 | 66249 | CR1000 | Maintenance | Data Logger IRT | I changed this data logger Pakbus id from 1 to 49 - the last two digits of its serial number. |
2022-06-07 | 2143 | CR23X | Removed | none | Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed |
2022-06-07 | 47772 | CR10X | Removed | Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed | |
2022-10-05 | 2301 | CR23X | Removed | Data Logger Soil CO2 | The soil co2 gradient system has not been in good condition for a long time. Finally getting around to removing the equipment from the field. |
2022-11-03 | 2301 | CR23X | Installed | none | Installed with the IRT sensor sn 7385 from the cal panel near the Floor solar panels for an IRT calibration for Robert's Oakley bike transect data this past summer |
2022-11-17 | 2301 | CR23X | Removed | none | Removed from Tonzi at the conclusion of the IRT calibration along with IRT sensor sn 7385 |
2023-06-16 | 4190 | CR1000 | Installed | none | Installed at the tower top as part of the Arduino RSB diffuse PAR prototype to compare with the BF5 |
2023-07-06 | 4190 | CR1000 | Removed | Removed from the Tower Top where it was part of the Arduino based RSB diffuse PAR prototype | |
2024-04-22 | 66249 | CR1000 | Removed | Data Logger IRT | Removed from the IRT tripod because cows had chewed the wires off. |
2024-06-04 | 66249 | CR1000 | Installed | Data Logger IRT | Reinstalled at the little tree northeast of the Tower at Tonzi after having been removed to repair massive cable damage from cows |
2024-10-29 | 13214 | CR10X | Installed | Data Logger StemFlux East | Installed east of the Floor tower to measure tree trunk temperatures for Kuno's stem flux experiment |
2024-10-29 | 3501 | CR10X | Installed | Data Logger StemFlux West | Installed west of the Floor tower to measure tree trunk temperatures for Kuno's stem flux experiment |
2024-10-29 | 19481 | CR10X | Installed | Data Logger StemFlux North | Installed north of the Floor tower to measure tree trunk temperatures for Kuno's stem flux experiment |
Forced Diffusion | |||||
2017-10-18 | 20160003 | eosFD | Installed | Installed near the Tree 1 soil CO2 profile for three month experiment | |
2017-10-25 | 20160002 | eosFD | Installed | Installed near the Open (East) soil CO2 profile for three month experiment | |
2017-12-14 | 20160002 | eosFD | Removed | Removed from the Tonzi soil CO2 profile in the Open (East) location. This FD chamber has been reporting zero flux with nearly identical CO2 readings for both cells. The pump seems to be running though. | |
2018-01-15 | 20160003 | eosFD | Removed | Removed from the soil co2 profile near Tree 1 for return to Eosense. | |
2019-11-19 | FD20180068 | eosFD | Installed | Forced Diffusion Tree 1 | Installed under the tree at the Tonzi soil co2 profiles |
2019-11-19 | FD20180026 | eosFD | Installed | Forced Diffusion Open | Installed in the open at the Tonzi soil co2 profiles |
Gas Analyzer | |||||
2011-10-13 | AKC-0479 | LI-800 | Removed | Removed from the CO2 profiles system because of strange values and would not calibrate. | |
2011-12-18 | AKC-0479 | LI-800 | Removed | Removed from the co2 profile system on the Tonzi Tower because it reading was pegged at max (1000ppm). TC wires cut. | |
2013-05-08 | AKC-0479 | LI-800 | Removed | This Li800 was removed from the CO2 profile system on the Tonzi Tower where is was often drifting out of range and railing. | |
2016-07-07 | CGA-556 | LI-820 | Calibration | Last calibration was 2016-06-16 Cell T = 52.2, Pressure = 91.0 Zero Air offset = -2.0ppm Span CO2 405ppm offset = 5.0ppm Zero 0.9472 -> 0.9467 Span 0.8496 -> 0.8369 | |
2017-11-29 | 75H-2182 | LI-7500A | Removed | Removed from the Tonzi Tower for calibration. Replaced by sn 75H-2668 | |
2018-02-20 | 75H-2182 | LI-7500A | Calibration | Lab | Last calibration: 2017-08-16 AGC=87 SDM=0 DAC1=0 DAC2=0 Ambient P=101.1kPa, Tair=23.3C, Tdew=-.8C Zero Air at 250psi, LBL Air 408.97 at 1700 Tdewspan=16.00 CO2 zero 0.8832 -> .8844 Offset: 5.24ppm CO2 span 1.0123 -> 1.0215 Offset: -4.81ppm H2O zero 0.8436 -> .8446 Offset: 6.7ppm H2O span 1.0038 -> 1.0038 Offset: 0ppm Notes: I didn't do a new H2O span because the dewpoint measurement was hovering around 2C, when the dewpoint generator was set to 16.00C. There might be an issue with the dewpoint generator. |
2017-11-29 | 75H-2180 | LI-7500A | Removed | Removed from the Tonzi Floor for calibration. Replaced by sn 1594 | |
2018-01-10 | 75H-2180 | LI-7500A | Calibration | Lab | Last calibration: 2017-08-16 AGC=97.8 SDM=0 DAC1=0 DAC2=0 Ambient P=101.1kPa, Tair=17.4C, Tdew=10.6C Zero Air at 250psi, LBL Air 408.97 at 1700 Tdewspan=16.00 CO2 zero 0.9129 -> 0.9147 Offset: 7.92ppm CO2 span 1.0145 -> 1.0362 Offset: -10.74ppm H2O zero 0.8871 -> 0.8864 Offset: -4.2ppm H2O span 1.0164 -> 1.0168 Offset: -0.02ppm Notes: |
2017-11-29 | CGA-556 | LI-820 | Installed | Installed in the Tower CO2 profile system after lab cleaning and calibration | |
2017-12-14 | CGA-556 | LI-820 | Removed | Removed from the Tower co2 profile for cleaning and calibration. The rest of the profile equipment was turned off | |
2018-02-21 | CGA-556 | LI-820 | Installed | Installed in the old CO2 profile system on the Tower for comparison of the new GMP343 profile. | |
2018-05-23 | CGA-556 | LI-820 | Removed | Removed from the Tonzi Tower with the old CO2 profile system. New Vaisala profile system is running | |
2023-09-19 | 0073 | LI-7500A | Removed | Gas Analyzer CO2/H2O Floor | Removed from Tonzi-Floor for calibration. Replaced by sn 0041. |
2023-10-05 | 0073 | LI-7500A | Calibration | Lab | Last calibration: 2023-06-13 AGC=100.6 SDM= DAC1= DAC2= AIU sn AIU-1569, Presure A0=58.004, A1=15.479 Ambient P=100.39kPa, Tair=30.62C, Tdew=11.88C Zero Air at 725psi, AMP CA04119 524.77 at 800 Tdewspan=20.00 CO2 zero 0.9161 -> .9167 Offset: 2.66ppm CO2 span 1.0093 -> 1.0064 Offset: 2.19ppm H2O zero 0.8328 -> .8296 Offset: -17.9ppm H2O span 1.0281 -> 1.0109 Offset: .38ppm Notes: Vertical orientation. Slightly larger than usual H2O zero offset |
2023-09-19 | 0041 | LI-7500A | Installed | Gas Analyzer CO2/H2O Floor | Installed at Tonzi-Floor to replace sn 0073 for calibration. |
2024-01-03 | 0041 | LI-7500A | Calibration | Lab | Last calibration: 2023-09-18 AGC=100 SDM=0 DAC1=- DAC2=- AIU sn AIU-1866, Presure A0=58.31, A1=15.48 Ambient P=100.8kPa, Tair=22.7C, Tdew=7.3C Zero Air at 550psi, AMP CA04119 524.77 at 750 Tdewspan=20.0 CO2 zero 0.9965 -> 0.9963 Offset: -0.79ppm CO2 span 1.0192 -> 1.0217 Offset: -1.67ppm H2O zero 0.8236 -> 0.8245 Offset: 5.0ppm H2O span 1.0292 -> 1.0365 Offset: -0.16ppm Notes: H20 took a long time (40min) to stabilize - kept creeping up |
2024-01-02 | 0041 | LI-7500A | Removed | Gas Analyzer CO2/H2O Floor | Removed from Tonzi Floor for calibration. Replaced by sn 75H-2667. |
2024-01-03 | 0041 | LI-7500A | Calibration | Lab | Last calibration: 2023-09-18 AGC=100 SDM=0 DAC1=- DAC2=- AIU sn AIU-1866, Presure A0=58.31, A1=15.48 Ambient P=100.8kPa, Tair=22.7C, Tdew=7.3C Zero Air at 550psi, AMP CA04119 524.77 at 750 Tdewspan=20.0 CO2 zero 0.9965 -> 0.9963 Offset: -0.79ppm CO2 span 1.0192 -> 1.0217 Offset: -1.67ppm H2O zero 0.8236 -> 0.8245 Offset: 5.0ppm H2O span 1.0292 -> 1.0365 Offset: -0.16ppm Notes: H20 took a long time (40min) to stabilize - kept creeping up |
2024-01-02 | 75H-2667 | LI-7500A | Installed | Gas Analyzer CO2/H2O Floor | Installed at Tonzi Floor to replace sn 0041 for calibration. |
2024-04-10 | 75H-2667 | LI-7500A | Calibration | Lab | Last calibration: 2023-12-20 AGC=99.6 SDM= DAC1= DAC2= AIU sn AIU-1866, Presure A0=58.31, A1=15.48 Ambient P=100.69kPa, Tair=24.8C, Tdew=11.0C Zero Air at 300psi, AMP CA04119 524.77 at 550 Tdewspan=20.00 CO2 zero 0.9413 -> .9409 Offset: -1.55ppm CO2 span 1.0207 -> 1.0213 Offset: -.35ppm H2O zero 0.8427 -> .8441 Offset: 8.5ppm H2O span 1.0363 -> 1.0404 Offset: -.09ppm Notes: Used 524.7 as the CO2 span point |
2024-03-26 | 75H-2667 | LI-7500A | Removed | Gas Analyzer CO2/H2O Floor | Removed from Tonzi Floor for calibration. Replaced by sn 75H-2176. |
2024-04-10 | 75H-2667 | LI-7500A | Calibration | Lab | Last calibration: 2023-12-20 AGC=99.6 SDM= DAC1= DAC2= AIU sn AIU-1866, Presure A0=58.31, A1=15.48 Ambient P=100.69kPa, Tair=24.8C, Tdew=11.0C Zero Air at 300psi, AMP CA04119 524.77 at 550 Tdewspan=20.00 CO2 zero 0.9413 -> .9409 Offset: -1.55ppm CO2 span 1.0207 -> 1.0213 Offset: -.35ppm H2O zero 0.8427 -> .8441 Offset: 8.5ppm H2O span 1.0363 -> 1.0404 Offset: -.09ppm Notes: Used 524.7 as the CO2 span point |
2024-03-26 | 75H-2176 | LI-7500A | Installed | Gas Analyzer CO2/H2O Floor | Installed at Tonzi Floor to replace sn 75H-2667 for calibration. |
2024-07-19 | 75H-2176 | LI-7500A | Calibration | Lab | Last calibration: 2024-03-23 AGC=103 SDM= DAC1= DAC2= AIU sn AIU-1866, Presure A0=58.31, A1=15.48 Ambient P=100.4kPa, Tair=21.2C, Tdew=16.5C Zero Air at 1700psi, AMP CA04119 524.77 at 350 Tdewspan=20.00 CO2 zero 0.8682 -> .8677 Offset: -2.2ppm CO2 span 1.0079 -> 1.0132 Offset: -3.94ppm H2O zero 0.8494 -> .8578 Offset: 52.3ppm H2O span 0.9236 -> .9377 Offset: -.34ppm Notes: First calibration after swapping internal chemicals on 2024-07-15. It has been running in the lab since the chemical swap. I used "524.75" as the CO2 span point in the 7550 software. I will test it again in a few days to make sure it's stable. |
2024-06-19 | 75H-2176 | LI-7500A | Removed | Gas Analyzer CO2/H2O Floor | Removed from Tonzi Floor for calibration. Replaced by sn 0041. |
2024-07-19 | 75H-2176 | LI-7500A | Calibration | Lab | Last calibration: 2024-03-23 AGC=103 SDM= DAC1= DAC2= AIU sn AIU-1866, Presure A0=58.31, A1=15.48 Ambient P=100.4kPa, Tair=21.2C, Tdew=16.5C Zero Air at 1700psi, AMP CA04119 524.77 at 350 Tdewspan=20.00 CO2 zero 0.8682 -> .8677 Offset: -2.2ppm CO2 span 1.0079 -> 1.0132 Offset: -3.94ppm H2O zero 0.8494 -> .8578 Offset: 52.3ppm H2O span 0.9236 -> .9377 Offset: -.34ppm Notes: First calibration after swapping internal chemicals on 2024-07-15. It has been running in the lab since the chemical swap. I used "524.75" as the CO2 span point in the 7550 software. I will test it again in a few days to make sure it's stable. |
2024-06-19 | 0041 | LI-7500A | Installed | Gas Analyzer CO2/H2O Floor | Installed at Tonzi Floor to replace sn 75H-2176 for calibration. |
2024-10-22 | 0041 | LI-7500A | Calibration | Lab | Last calibration: 2024-06-17 AGC=98.9 SDM= DAC1= DAC2= AIU sn AIU-1866, Presure A0=58.31, A1=15.48 Ambient P=100.7kPa, Tair=25.7C, Tdew=11.4C Zero Air at 1050psi, AMP FB04319 514.07 at 800 Tdewspan=20.00 CO2 zero 0.9958 -> .9960 Offset: .54ppm CO2 span 1.0176 -> 1.0142 Offset: 2.36ppm H2O zero 0.8238 -> .8244 Offset: 3.3ppm H2O span 1.0341 -> 1.031 Offset: .08ppm Notes: |
2024-09-27 | 0041 | LI-7500A | Removed | Gas Analyzer CO2/H2O Floor | Removed from Tonzi Floor for calibration. Replaced by sn 0065. |
2024-10-22 | 0041 | LI-7500A | Calibration | Lab | Last calibration: 2024-06-17 AGC=98.9 SDM= DAC1= DAC2= AIU sn AIU-1866, Presure A0=58.31, A1=15.48 Ambient P=100.7kPa, Tair=25.7C, Tdew=11.4C Zero Air at 1050psi, AMP FB04319 514.07 at 800 Tdewspan=20.00 CO2 zero 0.9958 -> .9960 Offset: .54ppm CO2 span 1.0176 -> 1.0142 Offset: 2.36ppm H2O zero 0.8238 -> .8244 Offset: 3.3ppm H2O span 1.0341 -> 1.031 Offset: .08ppm Notes: |
2024-09-27 | 0065 | LI-7500A | Installed | Gas Analyzer CO2/H2O Floor | Installed at Tonzi Floor to replace sn 0041 for calibration. |
2024-10-10 | TG1-0421 | LI-7700 | Installed | Gas Analyzer CH4 Tower | Installed on top of the Tower by adding a new mount using L-brackets and a rail fitting removing existing Allen screws and reusing the sockets for standard 1/4-20 bolts. Wash box and spiked hat also installed. |
2024-10-10 | TG1-0514 | LI-7700 | Installed | Gas Analyzer CH4 Floor | Installed on the Floor tower by adding a new mount using L-brackets and a rail fitting removing existing Allen screws and reusing the sockets for standard 1/4-20 bolts. No wash box, hat but no spikes. |
Heat Flux Plate | |||||
2001-01-05 | 00068 | HFP01SC | Installed | Heat Flux Plate D | Likely first installation date and location estimated from notes and data. |
2001-01-05 | 000144 | HFP01 | Installed | Heat Flux Plate E | Likely first installation date and location estimated from notes and data. |
2001-01-05 | 000140 | HFP01 | Installed | Heat Flux Plate C | Likely first installation date and location estimated from notes and data. |
2001-01-05 | 000138 | HFP01 | Installed | Heat Flux Plate A | Likely first installation date and location estimated from notes and data. |
2001-01-05 | 000139 | HFP01 | Installed | Heat Flux Plate B | Likely first installation date and location estimated from notes and data. |
2011-11-16 | 000144 | HFP01 | Removed | Heat Flux Plate E | I removed this heat flux plate from the Tonzi understory location due to bad readings. I found that a gopher had cut the cable. In addition the the insulation on the cable was cracked and rotting. |
2011-12-01 | 000144 | HFP01 | Installed | Heat Flux Plate E | Reinstalled in the field in its orginial location. The ground was dry and crumbly. |
2012-01-09 | 2495 | HFP01SC | Installed | Installed at -8cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 2500 | HFP01SC | Installed | Installed at about 1m agl at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-09-05 | 000139 | HFP01 | Removed | Heat Flux Plate B | Removed from Tonzi Floor for repair and calibration. This sensor was about 3cm below the ground surface. The insulation of its cable was all cracked and rotting. This was SHF plate #2. |
2012-11-07 | 000139 | HFP01 | Installed | Heat Flux Plate B | Installed after calibration by Sebastian in BC. The original calibration factor was found to be stable. It was placed just south of the stand holding the HMP45 near another SHF plate. Siyan wants to keep the new plate litter-free to compare to the older plate. Both plates are near the south edge of the canopy and should get nearly full sunlight except for the shadow from the tower. |
2024-02-16 | 00068 | HFP01SC | Maintenance | Heat Flux Plate D | I dug this plate up. It was at about -10cm with voids below the plate. I soldered on a new cable amd cut off the calibration cable because the insulation on both was completely rotten. I put it back at -2cm. |
2024-03-07 | 000138 | HFP01 | Maintenance | Heat Flux Plate A | We dug this plate up to replace its cable that had all its insulation rotted off. The plate was 2-5cm below the surface – it was tilted and ground surface was not very flat. We put it back flat at 3cm and the new cable in conduit. |
2024-03-07 | 00068 | HFP01SC | Moved | Heat Flux Plate D | I moved this plate back down to -10cm where I found it before fixing its cable a couple weeks ago. |
2024-04-22 | 000139 | HFP01 | Removed | Heat Flux Plate B | Removed from Tonzi floor met because a cow had chewed the wire and pulled the plate out of the ground. |
2024-05-08 | 000139 | HFP01 | Installed | Heat Flux Plate B | Reinstalled at Tonzi Floor in flexible aluminum conduit. It might be at about -5cm - I was a little overwrought at the time. |
2024-05-15 | 000141 | HFP01 | Maintenance | Heat Flux Plate F | Rewired to new junction box and updated data logger program. |
Infrared Temperature | |||||
2010-12-09 | 1281 | SI-121 | Removed | Removed from Tonzi with the end of the surface temperature experiment. | |
2010-12-09 | 1282 | SI-121 | Removed | Removed from Tonzi with the end of the surface temperature experiment. | |
2012-01-09 | NO1107535 | OS136-1-MVC | Installed | Installed at SP3 southeast of the Tower. The sensor is pointing at the ground to the south at about a 45deg angle from vertical. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | NO1107536 | OS136-1-MVC | Installed | Installed at SP2 near the Tower. The sensor is pointing at the ground to the south at about a 45deg angle from vertical. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2015-05-06 | 1965 | SI-121 | Installed | Infrared Temperature Tree Crown | Installed at Tonzi to the east just north of the road. This sensor is point down on top of a small tree. |
2015-05-06 | 1964 | SI-121 | Installed | Infrared Temperature Grass A | Installed at Tonzi to the east just north of the road. This sensor is point down on a patch of ground cleared of grass. |
2018-06-01 | 7385 | SI-131 | Installed | Installed near the Floor Tower on a CR10X to give temperatures of a black panel as a reference for the thermal camera. | |
2019-01-13 | 1624 | SI-121 | Installed | Infrared Temperature Ref Panel B | Installed on a post pointing to the northeast and slightly downward at the south facing concrete reference panel near the Floor solar panels. The panel also was five thermocouples embedded in it. |
2019-04-16 | 7385 | SI-131 | Removed | Removed with the wooden cal panel for the FLIR because cows chewed the TC wires and the new cal panel is better | |
2019-05-30 | TS01-001 | TS01 | Installed | Installed near the Floor solar panels looking at the grass to the north. Footprint of about 0.7m x 0.35m diameter | |
2019-05-30 | 7638 | SI-131 | Installed | Installed near an oak tree about 25m north of the Floor solar panels. Measuring trunk temperature from about 40cm distance. | |
2019-05-30 | TS01-002 | TS01 | Installed | Installed near an oak tree about 25m north of the Floor solar panels. Measuring trunk temperature from about 110cm distance. | |
2019-05-30 | 7385 | SI-131 | Installed | Installed near the Floor solar panels looking at the grass to the north. Footprint of about 1.23m x 2.5m diameter | |
2019-11-19 | TS01-001 | TS01 | Removed | Removed from near the Floor solar panels. This sensor was looking at the grass. Ana needed its narrow FOV for her emissivity testing in the lab. | |
2021-03-17 | 7385 | SI-131 | Removed | Infrared Temperature Grass B | A cow ate the wire from the sensor to the data logger box. Removed for repair in the lab. |
2021-05-04 | 7385 | SI-131 | Installed | Infrared Temperature Grass B | Reinstalled after cows chewed the cable and the first attempt at a splice had a bad solder joint. |
2021-06-02 | 7385 | SI-131 | Moved | Infrared Temperature Grass B | Moved from pointing at the cal panel to pointing at the grass. It was moved to the cal panel to replace the IRT there for cleaning. I realized later that the grass is probably more important than cal panel but there should be a mini inter-comparison now. |
2021-06-24 | 1624 | SI-121 | Installed | Infrared Temperature Ref Panel B | Reinstalled after several tries where the wiring was confused. Originally removed because a wasp filled its port with mud and larva. |
2022-06-07 | 7385 | SI-131 | Removed | Infrared Temperature Grass B | Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed |
2022-06-07 | 7638 | SI-131 | Removed | Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed | |
2022-06-07 | 1624 | SI-121 | Removed | Infrared Temperature Ref Panel B | Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed |
2022-06-07 | TS01-002 | TS01 | Removed | Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed | |
2022-10-20 | NO1107536 | OS136-1-MVC | Removed | none | This sensor has not been sending good data from a while. Seems a woodpecker destroyed its window. Removed and brought in for disposal |
2022-10-20 | 7385 | SI-131 | Installed | Infrared Temperature Ref Panel A | Install at the Tonzi cal panel for calibration. But I damaged the data logger so not collecting data until next time. |
2022-11-17 | 7385 | SI-131 | Removed | Infrared Temperature Ref Panel A | Removed from Tonzi at the conclusion of the IRT calibration along with CR23X sn 2301 |
2024-04-10 | 1964 | SI-121 | Removed | Infrared Temperature Grass A | Removed from the IRT tripod at Tonzi where it was pointed at the ground. The cows ate its cable. |
2024-04-22 | 1965 | SI-121 | Removed | Infrared Temperature Tree Crown | Removed from the IRT tripod because cows had chewed the wires off. |
2024-06-04 | 1964 | SI-121 | Installed | Infrared Temperature Tree Crown | Reinstalled at the little tree northeast of the Tower at Tonzi after having been removed to repair massive cable damage from cows. This sensor is pointed at the tree crown. |
2024-06-04 | 1965 | SI-121 | Installed | Infrared Temperature Grass A | Reinstalled at the little tree northeast of the Tower at Tonzi after having been removed to repair massive cable damage from cows. This sensor is pointed at the grass. |
2024-10-29 | 7385 | SI-131 | Installed | Infrared Temperature StemFlux East | Installed east of the Floor tower to measure tree trunk temperatures for Kuno's stem flux experiment |
2024-10-29 | 7638 | SI-131 | Installed | Infrared Temperature StemFlux West | Installed west of the Floor tower to measure tree trunk temperatures for Kuno's stem flux experiment |
2024-10-29 | 1624 | SI-121 | Installed | Infrared Temperature StemFlux North | Installed north of the Floor tower to measure tree trunk temperatures for Kuno's stem flux experiment |
Interface | |||||
2012-01-09 | 1327 | CE4 | Installed | Installed in the Campbell Enclosure at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 1328 | CE4 | Installed | Installed in the Campbell Enclosure at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 1329 | CE4 | Installed | Installed in the Campbell Enclosure at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2015-04-08 | 13053 | NL115 | Installed | Installed with the Handar wind profile near the Floor tower. | |
2015-12-23 | 13053 | NL115 | Removed | Removed from the box for the wind profile near the Floor tower. | |
LED sensor | |||||
2018-05-23 | LED-05 | LED-NDVI | Removed | Removed from the Tonzi Tower because it has not been working for a while and there are Decagon SRS sensors from NDVI and PRI | |
Moisture Point | |||||
2001-11-10 | 000000402165 | PRB-K Type #8 | Installed | Installed near the understory tower by Dennis and Liukang | |
2001-11-10 | 000000574B4B | PRB-K Type #8 | Installed | Installed near the Floor solar panels by Dennis and Liukang | |
2001-11-10 | 000000402FF3 | PRB-K Type #8 | Installed | Installed near the water potential table and original sap flow measurements by Dennis and Liukang | |
2001-11-10 | 000000574632 | PRB-K Type #8 | Installed | Installed near the soil co2 measurements tower by Dennis and Liukang | |
2003-04-16 | 0000097A432E | PRB-K Type #8 | Installed | Installed at Tonzi furthest from big tree by Liukang | |
2003-04-16 | 0000097A3C6E | PRB-K Type #8 | Installed | Installed at Tonzi third closets to big tree by Liukang | |
2003-04-16 | 0000097A3B40 | PRB-K Type #8 | Installed | Installed at Tonzi second closest to big tree by Liukang | |
2003-04-16 | 0000097A4AAA | PRB-K Type #8 | Installed | Installed at Tonzi closest to big tree by Liukang | |
2005-01-27 | 00000A6D882B | PRB-K Type #8 | Installed | Installed at Tonzi by minirhizotron transect west of soil CO2 profiles | |
2005-01-27 | 00000A3D04E8 | PRB-K Type #8 | Installed | Installed at Tonzi by minirhizotron transect west of soil CO2 profiles | |
2005-01-27 | 00000A6D72F5 | PRB-K Type #8 | Installed | Installed at Tonzi by minirhizotron transect west of soil CO2 profiles | |
2015-04-08 | 000007931AFE | PRB-K Type #8 | Removed | Removed from a location near the main tower ground sensors due to a broken pin (2nd from bottom). Replaced by sn 00000128B8072 | |
2015-04-08 | 00000128B8072 | PRB-K Type #8 | Installed | Installed in a location near the main tower ground sensors to replace sn 000007931AFE that has a broken pin. | |
2016-11-17 | 00000128B8072 | PRB-K Type #8 | Removed | Removed from Tonzi near the main tower. This probe has two broken pins. | |
2016-11-17 | 00000FEDDAA1 | PRB-K Type #8 | Installed | Installed at Tonzi near the main tower to replace sn 00000128B8072 that has two broken pins | |
2017-12-14 | 000000574632 | PRB-K Type #8 | Removed | Removed from the location inside the soil co2 profile fence. This probe has been giving bad readings for a while and its lowest pin is broken off. | |
2019-12-03 | 000000574B4B | PRB-K Type #8 | Removed | Removed from Tonzi near the Floor solar panels. This probe has three broken pins and has not been measured in a long time but this was the first time the soil was wet enough to remove it by hand. | |
2021-02-10 | 000000402FF3 | PRB-K Type #8 | Removed | Soil Moisture Probe F -0.50m | Removed from Tonzi floor due to fixed readings for a long while. This sensor was out of the ground at the edge of the trees near the path to the tower. It was buried vertically with the top of the sensor 31cm below the surface - the time were 44-50cm below the surface. |
2024-01-02 | 00000A3D04E8 | PRB-K Type #8 | Removed | none | This probes has been broken for a long time - more than a year. Removed. It has a broken pin and the shaft is cracked. |
Multiplexer | |||||
2010-02-10 | 14049 | AM416 | Removed | This mux was removed from Tonzi. It was used for sap flow just west of the floor tower. CR10X sn 38347 was removed with it. | |
2010-06-24 | 14049 | AM416 | Installed | This multiplexor was installed with two soil heat flux plates in the floor radiation system. The HMP45C lines were moved from the CR10X to the multiplexor to make room for the multiplexor. | |
2011-02-03 | 14049 | AM416 | Removed | Removed with other equipment from near the Floor site at Tonzi. Used in recording supplimental PAR, net, shf and RH and T. | |
2012-01-09 | 10208 | AM16/32B | Installed | Installed in the Campbell Enclosure at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 10195 | AM16/32B | Installed | Installed in the Campbell Enclosure at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 10194 | AM16/32B | Installed | Installed in the Campbell Enclosure at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-09-06 | 1237 | AM16/32A | Removed | Removed with all the above ground components of the C1 sap flow station. This sap flow station has not been working for a while and there are no plans to continue sap flow measurements in the future. | |
2013-05-30 | 1164 | AM16/32A | Removed | Removed from the East sap flow station. This station had not been running for a long time. The data logger had been removed previously. The box, solar panel and above ground cables were removed also. | |
2016-10-13 | 1429 | AM16/32A | Removed | Removed from the non-functioning sap flow station within the Tower cow fence | |
2016-10-13 | 1430 | AM16/32A | Removed | Removed from the non-functioning sap flow station within the Tower cow fence | |
2016-10-13 | 1236 | AM16/32A | Removed | Removed from the non-functioning sap flow station north of the road | |
2023-10-04 | 1237 | AM16/32A | Removed | Multiplexer Tower | Removed from the Tower top due to spikes on multiple channels. Replaced by sn 31675 |
2023-10-04 | 31675 | AM16/32B | Installed | Multiplexer Tower | Installed on the Tower top to replace sn 1237 which was removed due to spikes on multiple channels. |
Narrow Band | |||||
2017-09-07 | 943203017 | SRS-Nr NDVI | Installed | Installed on the post holding the floor met data logger box. This sensor is point to the north and about 30 degrees up to see just the trees and not the grass. | |
2020-10-22 | 943203017 | SRS-Nr NDVI | Removed | Removed from the Tonzi floor met because it was no longer being used - tree NDVI pointing to the sky doesn't work | |
Net Radiometer | |||||
2001-05-20 | 990351 | NR-LITE | Installed | Installed on the Tower top with the initial set up of the site | |
2002-02-08 | 990350 | NR-LITE | Installed | Gas Analyzer CO2/H2O | Installed inside the orange fence on the floor met CR10x data logger. |
2010-03-16 | 990350 | NR-LITE | Installed | Installed at the request of Hideki under the oak canopy near the radiation tram at Tonzi. | |
2010-03-16 | 041556 | NR-LITE | Installed | none | Installed at the request of Hideki in an unshaded opening near the east end of the radiation tram. |
2011-02-03 | 990350 | NR-LITE | Removed | Removed from under the trees near the floor tower. | |
2012-01-09 | 1514 | NR01 | Installed | Installed at -8cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
PAR Sensor | |||||
2001-05-07 | LQ1570 | Line Quantum | Moved | none | Moved from Vaira to Tonzi |
2001-05-20 | 990021 | PAR-LITE | Installed | Installed on the Tower top as a calibration sensor | |
2001-05-20 | 990019 | PAR-LITE | Installed | Installed on the Tower Top in the incoming PAR position. | |
2001-05-20 | 990017 | PAR-LITE | Installed | Installed on the Tower top in the reflected PAR location with the initial set up of the site | |
2001-09-07 | Q29881 | LI-190SA | Installed | PAR Sensor Incoming | Installed on the Tower top in the incoming position |
2001-09-07 | Q29892 | LI-190SA | Installed | Installed on the Tower top in the outgoing position | |
2004-04-30 | 010159 | PAR-LITE | Installed | PAR Sensor Incoming Cal | Installed on the radiation boom in the incoming position for inter-comparison with the existing Licor Quantum sensor. |
2004-04-30 | 030382 | PAR-LITE | Installed | PAR Sensor Reflected Cal | Installed on the radiation boom for comparison with existing Licor Quantum sensor |
2007-01-19 | Q29892 | LI-190SA | Removed | Removed from Tonzi Tower top. | |
2007-01-19 | Q29881 | LI-190SA | Removed | PAR Sensor Incoming | Removed from Tonzi Tower top. |
2010-03-16 | 010161 | PAR-LITE | Installed | Installed at the request of Hideki in an unshaded opening near the east end of the radiation tram at Tonzi. This sensor is pointing upward collecting incoming PAR. | |
2010-03-16 | 010163 | PAR-LITE | Installed | Installed at the request of Hideki in an unshaded opening near the east end of the radiation tram. This sensor is pointed downward collecting reflected PAR. | |
2011-02-03 | 010161 | PAR-LITE | Removed | Removed from the open space near the floor solar panels. | |
2011-02-03 | 010163 | PAR-LITE | Removed | Removed from the open space near the floor solar panels. | |
2016-07-07 | LQ1570 | Line Quantum | Removed | Discovered buried in grass and soil near the other floor sensors after years of being missing. Brought in to be cleaned up and tested. | |
2020-04-18 | 110340 | PQS 1 | Installed | PAR Sensor Under-A | The PAR sensor was installed at Tonzi on the z-cam 1 post to measure below canopy PAR. It is connected the the fmet CR23x |
2021-01-21 | 990031 | PAR-LITE | Installed | none | Installed as part of the inter-comparison kit to test PAR, AirT and RH on the top of the Tower. |
2021-02-10 | 990031 | PAR-LITE | Removed | PAR Sensor Incoming Cal | Removed from Tonzi Tower after three weeks of inter comparison with the AMP standard |
2021-04-01 | 010164 | PAR-LITE | Location | PAR Sensor Incoming | Location for sensors currently at Tonzi |
2021-04-01 | 030382 | PAR-LITE | Location | PAR Sensor Reflected | Location for sensors currently at Tonzi |
2021-08-11 | 110340 | PQS 1 | Removed | PAR Sensor Under-A | Removed from Tonzi near z-cam 2 because the data seems not so useful. |
2021-10-06 | 010164 | PAR-LITE | Removed | PAR Sensor Incoming | Removed from Tonzi-Tower due to bad readings from a broken wire. Replaced by sn 110340. |
2021-10-06 | 110340 | PQS 1 | Installed | PAR Sensor Incoming | Installed at Tonzi to replace sn 010164 due to bad readings from a broken wire. |
2022-10-20 | 030382 | PAR-LITE | Removed | PAR Sensor Reflected | Removed from Tonzi due to random spikiness. Replaced by sn 990025. |
2022-10-20 | 990025 | PAR-LITE | Installed | PAR Sensor Reflected | Installed at Tonzi to replace sn 030382 that has been spiky. |
2023-06-16 | 010164 | PAR-LITE | Installed | none | Installed at the tower top as part of the Arduino RSB diffuse PAR prototype to compare with the BF5 |
2023-07-06 | 010164 | PAR-LITE | Removed | Removed from the Tower Top where it was part of the Arduino based RSB diffuse PAR prototype | |
Precipitation | |||||
2012-01-09 | 48102-611 | TE525 | Installed | Installed on the ground at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 48132-611 | TE525 | Installed | Installed on the ground at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 48130-611 | TE525 | Installed | Installed on the ground at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2018-10-17 | 24872-999 | TR-525I-R1 | Calibration | Got 88 of 100 tips - adjusted screws 2.5 turns CW | |
2018-10-17 | 48130-611 | TE525 | Calibration | Got 88 of 100 tips - adjusted screws 2.5 turns CW | |
2018-10-17 | 48132-611 | TE525 | Calibration | Got 134 of 100 tips - adjusted screws 4 turns CCW | |
2019-10-24 | 24872-999 | TR-525I-R1 | Calibration | I connected the bucket to a CR23x dripping 475ml of water through the bucket which should result in 100tips. I got 100 tips. | |
2019-10-24 | 48130-611 | TE525 | Calibration | I connected the bucket to a CR23x dripping 475ml of water through the bucket which should result in 100tips. I got 104 tips. I did not adjust it. | |
2019-11-07 | 48132-611 | TE525 | Calibration | Plug tipping bucket into the calibration CR23x and dripped 475ml of water through the bucket which should result in 100tips. Got 103 tips and did not adjust the bucket. | |
2019-11-07 | 48102-611 | TE525 | Calibration | Plug tipping bucket into the calibration CR23x and dripped 475ml of water through the bucket which should result in 100tips. Got 103 tips and did not adjust the bucket. | |
2020-12-18 | 48130-611 | TE525 | Removed | none | Removed from OSU SP1 for experiments in the lab. The cable was disconnected inside the tipping bucket and left in place in the field. |
2021-10-06 | 48132-611 | TE525 | Calibration | none | Tested with our new method using the peristaltic pump and 237ml of water which should result in 50 tips. 1/2 turn of the screws (CW+, CCW-) should adjust the number of tips by 2-3% (1-1.5 tips). Got 52 tips – I turned the screws one turn CCW. |
2021-10-06 | 48102-611 | TE525 | Calibration | none | Tested with our new method using the peristaltic pump and 237ml of water which should result in 50 tips. 1/2 turn of the screws (CW+, CCW-) should adjust the number of tips by 2-3% (1-1.5 tips). Got 50 tips – No adjustment |
2021-10-06 | 24872-999 | TR-525I-R1 | Calibration | none | Tested with our new method using the peristaltic pump and 237ml of water which should result in 50 tips. 1/2 turn of the screws (CW+, CCW-) should adjust the number of tips by 2-3% (1-1.5 tips). Got 54 tips – I turned the screws two turns CCW |
Radio | |||||
2012-01-09 | 35754 | RF401 | Installed | Installed in the Campbell Enclosure at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 35787 | RF401 | Installed | Installed in the Campbell Enclosure at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 35785 | RF401 | Installed | Installed in the Campbell Enclosure at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 1131631861 | Raven XT | Installed | Installed in the Campbell Enclosure at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2017-03-02 | 21520 | RF400 | Removed | Removed from the soil co2 box. The radio link stopped working in the field and I plan to use the old MD9 to replace it anyway. | |
2017-03-02 | 21519 | RF400 | Removed | Removed from the Tower computer box. The radio link stopped working in the field and I plan to use the old MD9 to replace it anyway. | |
2018-12-19 | 35754 | RF401 | Removed | Removed from the OSU SP3 system to test out data collection by LattePanda in the lab. | |
2018-12-19 | 35785 | RF401 | Removed | Removed from the OSU SP1 system to test out data collection by LattePanda in the lab. | |
2019-03-11 | 34362 | RF401 | Installed | Installed in the Tower computer box to connect the computer to the remote data loggers. | |
2019-03-11 | 35754 | RF401 | Installed | Installed in the OSU SP3 box to connect to the Tower computer. | |
2019-04-16 | 35785 | RF401 | Installed | Install in the OSU SP1 box near the soil co2 system to connect the CR3000 to the Tower computer. Using Pakbus mode at 38400 | |
2020-03-02 | 32468 | RF401 | Installed | Radio IRT | Installed on the CR1000 for the small tree IRT system. |
2022-02-09 | 5A0331744701B101 | LX40-NA-WIFI | Installed | Radio Cell Modem | Add to the Tower top data logger box to provide remote connection. |
2024-04-22 | 32468 | RF401 | Removed | Radio IRT | Removed from the IRT tripod because cows had chewed the wires off. |
2024-06-04 | 32468 | RF401 | Installed | Radio IRT | Reinstalled at the little tree northeast of the Tower at Tonzi after having been removed to repair massive cable damage from cows |
RH & Temp | |||||
2003-01-21 | U3030032 | HMP45AC | Removed | none | Removed from Tonzi. Replaced by sn W0510026 |
2003-01-21 | W0510026 | HMP45AC | Installed | none | Installed at Tonzi to replace sn U3030032 for calibration. |
2010-03-16 | W0510026 | HMP45AC | Installed | Installed with radiation sensors for Hideki near the tram and floor eddy tower. This sensor is under the oak tree canopy. | |
2011-02-03 | W0510026 | HMP45AC | Removed | Removed from under the trees near the floor tower. | |
2016-11-02 | L2310711 | HMP60 | Installed | Installed on the top of the Tonzi Tower to compare with the existing HMP45 there. | |
2017-08-25 | L2310711 | HMP60 | Removed | Removed from Tonzi and brought back to the lab. It was installed for a comparison with an HMP45. The sensor is ready to use. | |
2018-01-15 | L2310711 | HMP60 | Installed | Insalled by a box just below the 3rd lowest location of the tower co2 profile. This sensor will be used to give real time air temperature to the GMP343s. | |
2024-02-27 | E5736 | HygroVUE10 | Installed | RH & Temp | Installed in the Floor RH/T location. Will cross compare with existing HMP45 before removing the old sensor. |
2024-03-26 | W0510026 | HMP45AC | Removed | RH & Temp Floor | Removed for Tonzi Floor met due to age and poor RH data. Replaced by new Hygrovue a few weeks ago. |
Soil Moisture Probe | |||||
2001-01-05 | 31/016 | ML2x | Installed | Installed at Tonzi at -25cm under the trees. | |
2001-01-05 | 31/085 | ML2x | Installed | Installed at the Tonzi Tower at -20cm in the open. | |
2001-01-05 | 31/033 | ML2x | Installed | Installed near the Tonzi Tower at the surface. | |
2001-01-05 | 31/092 | ML2x | Installed | Installed near the Tonzi Tower at -20cm in the open. | |
2001-01-05 | 31/100 | ML2x | Installed | Installed near the Tonzi Tower at -20cm under the trees. | |
2001-03-01 | 54/009 | ML2x | Installed | Installed near the Tonzi Tower at -50am. | |
2001-03-01 | 54/004 | ML2x | Installed | Installed near the Tonzi Tower at -50cm | |
2012-01-09 | 5TM-1342 | STD-5TM | Installed | Installed at -2cm at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TM-1286 | STD-5TM | Installed | Installed at -5cm at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TM-1315 | STD-5TM | Installed | Installed at -10cm at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TM-1388 | STD-5TM | Installed | Installed at -20cm at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TM-1297 | STD-5TM | Installed | Installed at -45cm at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TM-1395 | STD-5TM | Installed | Installed at -30cm at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TM-1296 | STD-5TM | Installed | Installed at -65cm at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TM-1306 | STD-5TM | Installed | Installed at -2cm at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TM-1285 | STD-5TM | Installed | Installed at -5cm at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TM-1282 | STD-5TM | Installed | Installed at -10cm at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TM-1396 | STD-5TM | Installed | Installed at -20cm at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TM-1407 | STD-5TM | Installed | Installed at -30cm at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TM-1308 | STD-5TM | Installed | Installed at -50cm at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TM-1405 | STD-5TM | Installed | Installed at -70cm at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TE-1278 | STD-5TE | Installed | Installed at -2cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TE-1287 | STD-5TE | Installed | Installed at -10cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TE-1281 | STD-5TE | Installed | Installed at -5cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TE-1393 | STD-5TE | Installed | Installed at -20cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TE-1275 | STD-5TE | Installed | Installed at -40cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TE-1274 | STD-5TE | Installed | Installed at -60cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 5TE-1400 | STD-5TE | Installed | Installed at -80cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2021-03-17 | 139/052 | ML2x | Installed | Soil Moisture Probe F -0.50m | Installed in the same location and depth as the one the died and was previously removed. This probe is buried vertically with its times at 44-50cm. It is at the drip line of the tree to the SE of the data logger box. |
2022-06-07 | 2676 | SoilVUE10 | Installed | Soil Moisture Probe H Profile | I installed this probe in the open to the south of the Floor met boxes towards the Tower along the existing power conduit. I cut a hole in the conduit and ran the cable back to the Floor CR23x. This is SoilVue B in the data. |
2022-06-07 | 2674 | SoilVUE10 | Installed | Soil Moisture Probe I Profile | I installed this probe to the west of the Floor met boxes near the existing Moisture Point probe and soil matrix sensor under the trees. This is SoilVue A in the data. |
2022-06-07 | 2688 | SoilVUE10 | Installed | Soil Moisture Probe J Profile | Installed near the OSU-SP1 soil sensors. This is SoilVue C in the data. |
2024-05-08 | 31/100 | ML2x | Removed | Soil Moisture Probe B -0.20m Tree | Removed from Tonzi because I cut its cable while digging a hole to reinstall a SHF plate. I'm sure this was #2 on the data logger ant the smap entry says tree, but this was about 3m south of the box in a mostly open area. Tines were vertical 16-22cm deep. |
2024-05-22 | 31/100 | ML2x | Installed | Soil Moisture Probe B -0.20m Tree | Reinstalled in the original location after being repaired in the lab for cow chew |
Soil Water Potential | |||||
2012-01-09 | 15843 | SX229 | Installed | Installed at -10cm at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15942 | SX229 | Installed | Installed at -65cm at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15824 | SX229 | Installed | Installed at -5cm at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15825 | SX229 | Installed | Installed at -30cm at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15833 | SX229 | Installed | Installed at -20cm at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15839 | SX229 | Installed | Installed at -45cm at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15856 | SX229 | Installed | Installed at -50cm at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15840 | SX229 | Installed | Installed at -30cm at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15822 | SX229 | Installed | Installed at -10cm at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15846 | SX229 | Installed | Installed at -5cm at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15818 | SX229 | Installed | Installed at -20cm at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15836 | SX229 | Installed | Installed at -70cm at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15764 | SX229 | Installed | Installed at -80cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15730 | SX229 | Installed | Installed at -40cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15852 | SX229 | Installed | Installed at -5cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15802 | SX229 | Installed | Installed at -10cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15729 | SX229 | Installed | Installed at -20cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | 15731 | SX229 | Installed | Installed at -60cm at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2022-04-27 | G20007112 | TEROS21 | Installed | Water Potential A | Installed near the drip line of the trees near the Tower Moisture Point probe |
2022-04-27 | G20010035 | TEROS21 | Installed | Soil Water Potential B | Installed near the base of a tree near the Tower Moisture Point Probe |
2022-06-07 | G20007096 | TEROS21 | Installed | Soil Water Potential C | Installed near the OSU-SP1 soil sensors at -10cm, vertical orientation |
2024-05-08 | G20007096 | TEROS21 | Removed | Soil Water Potential C | Removed from the OSU SP1 system at Tonzi for testing. It wasn't giving data. Cows might have damaged its cable. |
2024-05-15 | G20007096 | TEROS21 | Installed | Soil Water Potential C | Reinstalled in close to the original location at about -10cm after repairing the cow chewed cable in the lab |
Solar Controller | |||||
2016-03-08 | 0135002X | PS-30M | Moved | I moved this charge controller from the Tram solar system to the main Tower power system. The existing charge controller at the tower sn 02431248 stopped reading the battery voltage. | |
2017-09-28 | SCC-001 | C60 | Removed | Removed from the Tonzi Tower solar system. The system was upgraded with a new MPPT charge controller. | |
2017-09-28 | 0135002X | PS-30M | Removed | Removed from the Tonzi Tower solar system were it was serving as a Low Voltage Disconnect. The system was upgraded with a new MPPT charge controller. | |
2017-09-28 | KB04594 | MNKID-B | Installed | Installed on the Tonzi Tower to upgrade the solar system. The solar system is now three parallel strings of four panels in series approximately 12A at 80VDC. The battery bank was rewired to be a 24V system. | |
2018-04-25 | 186580399 | PS-30M | Location | This charge controller is running the soil CO2 solar system. The system is 24V. It has been here for at least the last 10 years. | |
2018-05-11 | 3317052234210 | CMTD-As4s0 | Installed | none | Installed at the Road Well to power Global Water sensor. |
2020-07-07 | 0127000A | PS-30M | Removed | none | Removed from the Floor solar system. I needed a 30A model for the tower going to Steve and Sabina. Since updating this system 24V the amp load has decreased below 15A. Replaced by sn 12501584. |
2020-07-07 | 186580399 | PS-30M | Removed | Removed from the Soil CO2 box under the tree. This is an old 1st generation model. I put in a newer 15A 2nd model sn 12501588 since the power requirements here are small. | |
2020-07-07 | 12501584 | PS-15M | Installed | none | Installed at Tonzi to replace sn 0127000A for use elsewhere. Since updating the solar power to 24V the 30A model is not required. |
2020-07-07 | 12501588 | PS-15M | Installed | none | Installed in the Soil CO2 box under the tree at Tonzi. I swapped out an old 1st gen 30A model sn 186580399. |
2023-03-01 | 12501588 | PS-15M | Removed | Solar Controller Soil CO2 | This solar controller has not been showing solar amps and doesn't seem to charge batteries. I brought it in for testing |
2023-03-01 | 21501223 | SS-6L-12V | Installed | Solar Controller Soil CO2 | Installed at the soil CO2 battery bank to replace sn 12501588 that doesn't seem to be charging batteries. |
Solar Panel | |||||
2010-08-19 | 04592G0181 | KC40 | Removed | none | Removed from the Tram charging station so that two 20W panels could be use for a 24V system. |
2012-01-09 | T21009229B43638 | SX350J | Installed | Installed at SP3 southeast of the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | T21009229B43579 | SX350J | Installed | Installed at SP2 near the Tower. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-01-09 | T21009229B37030 | SX350J | Installed | Installed at SP1 inside the soil co2 fence. This is the initial setup of the site by Richard Cuenca and Yutaka Hagimoto of Oregon State Univ. | |
2012-02-09 | 020854E-6-03-02-06905 | SP75 | Removed | Solar Panel Floor G | Removed from the Floor solar system. This panel has not been connected to the system since at least August 2008 |
2012-02-09 | 020854E-6-03-02-06862 | SP75 | Removed | Solar Panel Floor H | Removed from the Floor solar system. This panel has not been connected to the system since at least August 2008 |
2022-02-09 | T21009229B43579 | SX350J | Removed | Removed from OSU SP2 with the dying battery. Replaced with a power line from the Tower battery bank. | |
Water Level | |||||
2018-02-07 | 1260403156 | CTD-10 | Installed | Installed in the well near the Floor tower. The sensor is 11.1m below the top of the white pipe. It is connected to the CR200. | |
2018-03-27 | 57278 | WL16U | Removed | Water Level Floor | Removed from the Floor Well. The cable insulation is rotting and needs to be replaced. Replaced by the new METER water level sensor a couple of weeks ago. |
2018-05-11 | 57278 | WL16U | Installed | Water Level Road | Installed at the Road Well to measure water level at 5min intervals storing 30min averages |
2021-04-18 | 1260403156 | CTD-10 | Removed | Water Level Floor | I found it's cable chewed. I cut of the chewed part and reattached but still no data. Power and data lines seems continuous. Maybe chewing shorted out something. |
2021-05-04 | 1260403156 | CTD-10 | Installed | Water Level Floor | Reinstalled after cows chewed the extension cable and Joe couldn't figure out the wiring. |
Weather Station | |||||
2019-07-02 | A000251 | Mark I | Installed | Installed at the top of the tower east of the southeast corner. Should be remounted on the radiation boom. | |
2021-08-11 | A000251 | Mark I | Removed | Weather Station | Removed from the Tower top due to not sending data and one of the incoming sensors was removed by woodpeckers. |