<--2006-10-11 00:00:00 | 2006-10-21 00:00:00-->Other sites visited today: Tonzi
Phenocam link: Searching...
Vaira: 2006-10-20 00:00:00 (DOY 293)
Author: Ted Hehn
Others:
Weather Clear and warm
Trip Purpose General site visit Soil heat flux plates 1 & 2 failed – critters chewed through signal leads. Thermocouple wire on soil temp profile probes also showing chew markings. SHF # 2 buried due west of MUX enclosure sn 141 59.0 uV/w/m2 SHF #1 buried 45 degree south of due west sn 137 60.0 uV/w/m2 SHF #3 buried 135 degree south of due west sn Remove SHF # 1& 2 from ground and replace and install signal leads inside conduit on all 3 units. I did not log the calibration numbers for the 2 soil heat flux plates and will record them on my next visit. |