Rec No. | Date | Loc From | Title | Loc To | Notes |
6474 |
2023-11-20 |
Bouldin Corn Air Quality Sensor |
Removed |
Lab none |
Removed from BC tower and brought back to the lab. It needs a new data card slot. The current card slot has a bad spring mechanism so cards don't physically mount. |
6473 |
2022-11-02 |
Lab none |
Installed |
Bouldin Corn Air Quality Sensor |
Installed at BC on the tower |
6046 |
2022-10-18 |
Bouldin Corn Air Quality Sensor |
Removed |
Lab none |
Removed from BC tower and brought back to the lab for further inspection. Data over the summer seemed spiky. |
5635 |
2021-12-14 |
Lab none |
Installed |
Bouldin Corn Air Quality Sensor |
Installed at Bouldin Corn on the southwest scaffolding post. It is powered by mini-USB-to-USB cable that connects in the dfPAR CR10X enclosure. The microSD card slot is tucked up into the inner PVC shield to prevent water from dripping on it. The card slot is easy to pull out and tuck back in when I need to access the card. |
5652 |
2021-12-13 |
Lab none |
Maintenance |
Lab none |
This sensor had some corrosion on one of the power connectors inside the sensor (it got rained on after the BC tower fell over), so Joe bypassed it by attaching one long mini-USB-to-USB cable. The clock was also ahead by one day. I brought the sensor home to connect to my home wifi for a few hours for the clock to automatically sync with the network. I checked the data files on the card and the timestamps were good. |
5081 |
2021-01-29 |
Bouldin Corn Air Quality Sensor |
Removed |
Lab none |
Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Got rained on and the power connector is corroded |
4938 |
2020-10-22 |
Lab none |
Installed |
Bouldin Corn Air Quality Sensor |
Installed at BC to replace sn 68c63acc07a9, which was brought back to the lab. |
4777 |
2020-09-23 |
Bouldin Corn Air Quality Sensor |
Removed |
Lab none |
Removed from BC and brought back to the lab for testing because it does not consistently have files on the card |
4681 |
2020-08-21 |
Lab none |
Installed |
Bouldin Corn Air Quality Sensor |
Installed at BC on the SW corner of the tower |
4684 |
2020-02-12 |
Bouldin Corn Air Quality Sensor |
Removed |
Lab none |
Brought back to the lab for inspection b/c the wifi network was not coming up |
4311 |
2019-12-17 |
Lab none |
Installed |
Bouldin Corn Air Quality Sensor |
Installed at Bouldin Corn after the tower was rebuilt after being knocked down by the wind. The older Purple Air is still in the lab drying out and needs to be put back together. |
4275 |
2019-12-06 |
Loaned |
Returned |
Lab none |
Returned by Tomo Yoshino and friends from their undergraduate project looking at air quality in BART stations. |
4156 |
2019-11-14 |
Lab none |
Loaned |
Loaned |
Loaned to Tomo Yoshino and friends for undergraduate project looking at air quality in BART stations. |