Rec No.DateLoc FromTitleLoc ToNotes
4799 2020-09-16 Vaira Battery Bank SoilCO2 Maintenance Vaira Battery Bank SoilCO2 I checked the water in the soil co2 battery bank. The water levels were low exposing the plates but these batteries didn’t take that much water – about a gallon to fill all of them.
3478 2018-06-05 Twitchell Alfalfa Replaced Vaira The battery bank from Twitchell Alfalfa was installed to replace the original batteries here that had a catastrophic failure
4644 2012-03-21 Lab none Installed Vaira none I installed new batteries (borrowed from DWR) for the new soil co2 system. The original batteries were killed because they were wired for 24V and the solar for 12V.
4643 2012-03-19 Vaira Removed Lab none The four new batteries for the soil CO2 sensors were completely dead (~2V). The batteries were wired for 24V but the solar panels were wired for 12V. Batteries removed.
4642 2012-02-16 Lab none Installed Vaira none Initial installation of the VR_soilco2 battery bank. Two pairs of deep cycle batteries were installed for a 24V system. However the solar panels were only wired as 12V and bled the batteries dry.