Equipment and Calibration History

History for TE Technology HP-127-1.0-1.3-71P P04

Rec No.DateLoc FromTitleLoc ToNotes
2104 2015-12-02 Lab none Installed Vaira Reinstalled at Vaira at -16cm. This was spliced onto the existing cable in the field.
2113 2015-12-01 Lab none Repair Lab none The red wire had broken right where it met the plate. I was able solder on a new wire. I covered the wires with heat shrink and painted the connections to the plate.
2111 2015-11-20 Vaira Removed Lab none Removed from Vaira at -16cm. Looks like the insulation had cracked and the wire rotted.
918 2013-02-06 Lab none Installed Vaira Installed in a profile at -16cm to the east of the Vaira radiation tower
923 2013-01-16 Lab none Calibration Lab none Calibrated by Sebastian at University of British Columbia: Multiplier = 106.2(W/m2)/mV