Field Notes
<--2022-02-03 11:00:00 | 2022-03-01 15:20:00-->Other sites visited today: Hill Slough | Mayberry | Bouldin Alfalfa
Phenocam link: Searching...
Bouldin Corn: 2022-02-17 11:15:00 (DOY 48)
Author: Daphne Szutu
Others: Carlos
Summary: Regular data collection/cleaning, reinstalled FD chamber, mounted power box enclosure, changed phenocam clock +1min, changed eddy clock +1min
2022-02-17 Bouldin Corn Carlos and I arrived at 11:15 PST. It was mild, sunny, and mostly still. The field is mostly dry now with just a few puddles remaining. We drilled new holes into the power box enclosure’s backplate and mounted it to the new metal pole with u-bolts. I downloaded met, cam, and USB GHG data. I downloaded the PA data and power cycled it. I downloaded the IRT data by swapping the microSD card and using CardConvert to convert the fast data to TOB1 and the slow data to TOA5. I changed the phenocam clock +1min from 12:02 to 12:03 to match the laptop time. I also changed the eddy clock +1min from 12:01 to 12:02 and restarted logging after the change. Carlos cleaned flux and rad sensors and topped off the wash reservoir. There was a dead fly on the lower 7700 mirror. We installed the eosFD chamber sn FD20180067 under the tower. I confirmed that its clock matched the laptop time and that sampling frequency was set at 5min. LI-7500 readings: CO2 437ppm H2O 377ppm T 14.6C P 102.6kPa SS 101 --> 103 after cleaning LI7700 readings: CH4 2.5ppm RSSI 37 --> 78 after cleaning We left at 12:10 PST. |