When: Tue, 22Mar05 JD-81-
Where: Tonzi/Vaira Ranches
Who: Ted Hehn & Matthias
Weather Tuesday raining hard and rivers are flowing through the Floor system and about ½ inch of water is present everywhere on the ground.
Flowers beginning to bloom. Yellow and purple/blue

Tonzi Ranch:
22Mar05 Tuesday arrive and all systems running. Heavy rain.

23Mar05
12:45 Wednesday
Floor system

Batt V = 12.5
Solar A = 4.0 This does not compare well with the Vaira site.
Load A = 2.0
Charge status Green

Tower
Batt V = 11.7
Solar A =
Load A = 7.0
Charge status Blinking Red

Thursday 13:07
Remove Cr10x7 wp 21291 x31307 cal 7/22/02 due 7/22/03
Install CR10x wp 10203 x19482 cal 8/31/99 due 8/31/00

Remove ground wire from cr10x7 post to MD9 -> multipoint ground

13:48 Install ITPS low dropout regulator power sequencer module with 5 second power on delay on CR10x7 to reduce power up failures on the CO2 profile system.

Check tower batteries with electrolyte tester. Batts closest to inputs have more capacity than those further away. Results range from poor to fair.

14:06
CO2 & water channels of LI7500 very noisy and there is no structure to traces.

Visual inspection of LI7500 indicates water present on inside of case on lens of the upper egg.

14:31 Floor

Send measur18.dld to CR10x7 from tower computer and key pad shows LOG4 which is very, very strange. Press *0 and LOG1 shows on keyboard and system begins to operate.

Communication with CR107 from floor PC has been lost. This happens every time I use the tower PC to communicate with CR10x7. Pulling power plug on cr10x7 is only method to reestablish communication.

Check electrolyte in floor system batteries when fully charged. Batts closest to input in upper fair range and those farthest away were in lower fair range.

Solar regulator at floor system in overcurrent drop out so I reset the system by disconnecting the battery input and removed 2 solar panels from the array.

16:07 tower
Water present in CO2 profile system intake tubing. Remove all filters and inspect. Level 1 (closest to ground – 1/ meter) had water present in intake filter and tubing. The filter on the LI820 intake showed slight signs of moisture on the intake side but was clean on the output side of the membrane. I don’t believe the LI820 was adversely affected.

The filter for the next highest level (1meter) also had water present in the filter but not in the tubing.

Use nitrogen cylinder and blow water from intake tubing.

Disassemble LI7500 #418 and egg was contaminated with water as is the base.

18:00 Shut down tower system and leave site.

Field Data

No tank data

No TZ Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

No data found for TZ_fflux.
8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

No data found for TZ_tram.
No data found for TZ_co2prof.
No data found for TZ_irt.
1 TZ_windprof graphs found

Wind Speed Profile

No data found for TZ_tflux.
2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met
1 TZ_met graphs found

Floor and Tower RH

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.