Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Field Notes

<--2005-03-22 00:00:00 | 2005-03-26 15:00:00-->

Tonzi: 2005-03-24 12:00:00 (DOY 83)
Author: Siyan Ma
Others: Qi Chen, Ted

Summary: Swapped Li-7500 in Vaira (Remove #65, install #41). Because Ted was there, I didn't check the flux system. Some serious problems mentioned by Ted.


When: Date: 3/24/2005 , Day: 84 , Watch Time: 12:00pm .
Where: Tonzi/Vaira Ranch
Who: Siyan, Qi Chen
Weather: Partially cloudy, ground very wet, flooding on Tue.
Phenology: Oak leaves comes out, ~1cm long. Flowers start coming out on the grassland.

Summary
  1. Swapped Li-7500 in Vaira (Remove #65, install #41).
  2. Because Ted was there, I didn’t check the flux system. Some serious problems mentioned by Ted:

· Ted found he didn’t install Licor-7500 on Tower site properly last time right before Hank was here. We got bad data during the comparison period.
· We need swap Tower’s Licor-7500 as soon as possible.
· Ted got shock by fence when he’s holding LED sensor, causing one channel of the sensor was out of range.
· Ted found there was some standing water in the lowest filter of CO2 profile system. So, he decided to stay in Tonzi one more night to fix the problem and also run responding curves.
  1. Used two sets of LAI-2000 measuring LAI along 400-m transects

1) Compare two sensors on the top of the tower
· SetUP: Rmt, Above, the same clock, sampling frequency = 15 seconds, sampling period = 10 mins. (using memory ~3%).
· Lenses are covered with 180oC mask.
· Direction is opposite to the Sun.
2) Leave one sensor on the tope the tower, holding tightly with a bondage
· SetUP: Rmt Above. sampling frequency =15 seconds. Sampling period = 1 hr.
3) Hold the one sensor in the level and do the “Below” measurement along “V” transects.
· SetUP: Rmt Blowe, Avg = 0. sampling frequency =
· Same mask as the tower one.
· Same direction as the tower one.

The number of files:
DDB set
1 – compare two sensors on the top of the tower
2 – transect
3 – coming radiation measured in open area
4 – compare two sensors on the top of the tower
5
6
7
8

Qi set
1 – compare two sensors on the top of the tower
2 – incoming radiation on the tower
3 –
  1. Collected Alex’s samples
  2. Collected grass and leave samples in Tonzi and Vaira.
  3. Soil moisture profiles and 40-m transect were measured.

1) To measure soil moisture profile, set up MODE = 008
2) To measure soil moisture using single diode probe, set up MODE = 009

tonzi

7931AFE

402165

574B4B

402FF3

574632

7A432E

7A3C6E

7A3B40

7A4AAA

D084










Mar. 24, 2005

Siyan









0-15

41.25

40

51.1

33.5

39

39.25

27.95

33.9

28.9

15-30

38.35

39.1

39.8

37.9

35.15

37.65

29.55

32.75

166.5

30-45

39

42.4

43.75

37.75

44.55

34.7

32.05

32.4

35.25

45-60

39.8

52.4

50.9

41.55

44

35.25

43.25

46.05

39.8












A6D882B

A3D04E8

A6D72F5

















0-15

35.85

33.75

25.95







15-30

27.8

33.8

33.95







30-45

37

33.35

33.9







45-60

43.1

48.8

44.35

















vaira

57318a

7933dee








0-15

32.4

17.13333








15-30

33.3

28








30-45

29.9

31








45-60

35.5

31.1








Field Data

No tank data

No TZ Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

No data found for TZ_fflux.
8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

No data found for TZ_tram.
No data found for TZ_co2prof.
No data found for TZ_irt.
1 TZ_windprof graphs found

Wind Speed Profile

No data found for TZ_tflux.
2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met
1 TZ_met graphs found

Floor and Tower RH

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.