Tonzi: 2005-01-27 10:50:00 (DOY 27)
Author: Dennis Baldocchi
Others: Jessica, Ted, James, Matthias

Summary: Swapped Tower 7500, install new moisture probes by minirhizon

When: Date: 1-27-2005 , Day: 27, Watch Time: 1050 .
Where: Tonzi/Vaira Ranch
Who: DB, JC, JD
Weather: Partly cloudy, very wet, rain last night
Phenology: green grass, deciduous trees

Tasks

  1. check Flux systems
  2. swap Li-7500 from Tower site (remove: sn 0041; install: sn 0065)
  3. Spectrum measurements (Mattias)
  4. soil moisture
  5. Install new soil moisture profile probes by the side of minirhizon transect

Tonzi_Tower Site

  1. Fence and gate power: OK v.
  2. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 � 5 v.)
    Time
    Path/File name D:/data/T05_027.flx
    mean std mean std
    w 0.15 0.182 Ts 15 0.12
    u -0.82 0.9 H2O 3.1 0.018
    v 1.6 1 CO2 1.3 0.004

  3. Light wind.

Tonzi_Floor Site

  1. Fence and gate power: OK v.
  2. Panel and Batteries: 12.3 v; 12.0 amps; 3.0 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 � 5 v.)
    Time 11:45
    Path/File name FL5_27.flx
    mean std mean std
    w -0.2 Ts 15.8
    u -0.98 H2O 2.96
    v -0.59 CO2 1.87 0

Field Data

No tank data

No TZ Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

No data found for TZ_fflux.
8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

No data found for TZ_tram.
No data found for TZ_co2prof.
No data found for TZ_irt.
1 TZ_windprof graphs found

Wind Speed Profile

No data found for TZ_tflux.
2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met
1 TZ_met graphs found

Floor and Tower RH

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.