Field Notes
<--2005-01-06 13:30:00 |
2005-01-27 10:50:00-->
Other sites visited today:
Vaira
Phenocam link:
Searching...Tonzi: 2005-01-17 13:59:00 (DOY 17)
Author: Siyan Ma
Others:
Summary: Floor site down due to low solar power, Swapped Floor 7500, leaf and grass samples
When: Date: 1/17/2005 , Day: 17 , Watch Time: 12:35pm . Where: Tonzi/Vaira Ranch Who: Siyan Weather: Cloudy, foggy, very wet on the grass
Phenology: green grass Summary
- No power for the fence of soil CO2 profile system.
- Tower site worked well. The attachment of computer need fix.
- Floor and Vaira Flux systems shut down because of “LVDâ€. After restart the power regulator, flux systems are working.
- Swap Li-7500 in floor site (Remove sn 0073, install sn 0418). #73 will be sent back to Li-cor for re-calibration.
- Measure soil moisture.
- Collect leave samples: Vaira grass, Tonzi understory grass
Tonzi_Tower Site
- Fence and gate power: >12 v.
- Panel and Batteries: 12.0 v; 0.0 amps; 3.5 amps.
- Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)
Time |
13:59:58 |
Path/File name |
D:\data\T05_17.flx, D:\data\TW05171030.flx |
|
mean |
std |
|
mean |
std |
w |
0.02 |
0.251 |
Ts |
8.707 |
0.114 |
u |
-1.13 |
0.445 |
H2O |
1.902 |
0.02 |
v |
-0.55 |
0.329 |
CO2 |
2.131 |
0.017 |
- I couldn’t download data because I couldn’t find the mouse. .
- Check calibration cylinders;
CO2 1500 psig; flow 10 psi. N2 500 psig; flow 10 psi.
- Close gate and set up fence.
Toniz_Floor Site
- Fence and gate power: >12.0 v.
- Panel and Batteries: 12.3 v; 2.9 amps; Lvd amps. After restart, “Lvd†changed into 4.2 amps.
- Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)
Time |
14:42:05 |
Path/File name |
FL5_17.flx |
|
mean |
std |
|
mean |
std |
w |
0.09 |
0.113 |
Ts |
11.568 |
0.195 |
u |
0.01 |
0.681 |
H2O |
0.001 |
0.001 |
v |
0.34 |
0.816 |
CO2 |
2.976 |
0.024 |
- Download data.
- Readings were OK from Gillsonic screen after downloading data or swaping Li-7500 Analyzer. (Remove sn 0073; install sn 0148)
Time |
15:05:41 |
Path/File name |
FL5_17.flx |
|
mean |
std |
|
mean |
std |
w |
-0.4 |
0.168 |
Ts |
11.064 |
0.167 |
u |
1.03 |
0.931 |
H2O |
2.104 |
0.021 |
v |
0.176 |
0.317 |
CO2 |
2.367 |
0.008 |
- No power on the fence of soil CO2 profile system.
- Close gate and set up fence.
|
Field Data
No tank data
No TZ Well data found
No TZ Moisture Point data found
No VR Moisture Point data found
No TZ grass heigth found
No VR grass heigth found
No TZ Tree DBH found
No water potential data found
No TZ Grass Biomass data found
No TZ OakLeaves Biomass data found
No TZ PineNeedles Biomass data found
0 photos found
16 sets found
No data found for TZ_Fenergy.
11 TZ_tmet graphs found
No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found
No data found for TZ_fflux.
8 TZ_fmet graphs found
No data found for TZ_tram.
No data found for TZ_co2prof.
No data found for TZ_irt.
1 TZ_windprof graphs found
No data found for TZ_tflux.
2 TZ_sm graphs found
Can't check TZ_met
1 TZ_met graphs found
Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data