Summary: Check on eddy systems - Floor missing data, repair and upgrade soil co2 power, fix TCs

When: Thurs, 6 Oct04
Where: Tonzi Ranch
Who: Ted Hehn
Weather Clear and warm

Trip Purpose Standard site visit

Tonzi Ranch:
6Oct04
Tower site working but missing 1-2 days data since last visit.

Floor system failure 24-48 hours ago. PC208 screen opened and gillsonic minimized. Close PC208 window and restart PC. Gillsonic initiated.

East side Soil CO2 Profile System (SCPS) had been reconfigured such that the IRGAs and data logger were being powered by 1 battery with 12 volts. The charging system configured to charge a 24 volt battery was charging the 12 volt battery. The Vaisala IRGAs are 24 volt devices. This configuration was corrected by reconnecting the batteries in series for a 24 volt system. Formerly, the CR23x was powered by its own battery that did not have solar charge capability. It is now powered by the lower potential battery of the 24 volt bank.

The west side soil CO2 profile system was not affected by what happened to the east side.

The CR23x at the East side SCPS was not functioning and removed. Another was installed and the system began to give reasonable readings. Repair soil thermocouple for east side # 2.

Field Data

No tank data

No TZ Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

No TZ Tree DBH found

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Explore the graph:Tonzi Tower Met: Temperature and Power in a new window

Explore the graph:Tonzi Tower Met: Solar Radiation in a new window

Explore the graph:Tonzi Tower Met: IRT Sensors in a new window

Explore the graph:LED Sensor Incoming in a new window

Explore the graph:LED Sensor Outgoing in a new window

Explore the graph:4-Band Solar Radiation in a new window

Explore the graph:Air Temperature Profile in a new window

Explore the graph:Relativity Humidity Profile in a new window

Explore the graph:Tonzi Tower PRI in a new window

Explore the graph:SRS PRI/NDVI in a new window

Explore the graph:SRS NDVI in a new window

No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found

Explore the graph:Tonzi PPT in a new window

Explore the graph:Tonzi CO2 and H2O Densities in a new window

Explore the graph:Air Pressure in a new window

No data found for TZ_fflux.
8 TZ_fmet graphs found

Explore the graph:Soil Heat Flux in a new window

Explore the graph:Tonzi Soil Temperature Set A in a new window

Explore the graph:Tonzi Soil Temperatures Set B in a new window

Explore the graph:Tonzi Soil Temperatures Set C in a new window

Explore the graph:Tonzi Soil Temperature Set D in a new window

Explore the graph:Well Level in a new window

Explore the graph:Well Water Temperature in a new window

Explore the graph:Soil Water Potential in a new window

No data found for TZ_tram.
No data found for TZ_co2prof.
No data found for TZ_irt.
1 TZ_windprof graphs found

Explore the graph:Wind Speed Profile in a new window

No data found for TZ_tflux.
2 TZ_sm graphs found

Explore the graph:Floor Solar Radiations in a new window

Explore the graph:TZ Soil Moisture in a new window

Can't check TZ_met
1 TZ_met graphs found

Explore the graph:Floor and Tower RH in a new window

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration