Field Notes

<--2004-09-16 10:00:00 | 2004-10-06 10:00:00-->
Other sites visited today: Vaira
Phenocam link: Searching...

Tonzi: 2004-09-21 11:16:00 (DOY 265)
Author: Siyan Ma
Others:

Summary: Floor laptop screen dying, Tower co2 profile shutdown - Li-800 brought in, Open soil CO2 battery dead, tree leaf samples

When: Date: 9/21/2004 , Day: 265 , Watch Time: 11:00 am .
Where: Tonzi/Vaira Ranch
Who: Siyan
Weather: Sunny, breeze, not hot
Phenology: Oak leaves looked more yellow. Dead grass.

Summary & Problems

  1. Overall, three Flux towers were working well. Data were downloaded. However, the Floor-site laptop screen didn’t show anything when I got there. After I restarted the laptop twice, the screen started working for me but still flushing all the time. Thus, the Floor-site laptop needs to be replaced soon.
  2. The battery in the open site of Soil CO2 profile was 10.986v, lower than normal 12.0v. I reconnected the power line to another good battery. I was not sure whether the batteries were connected to solar panels. I should bring the dead battery back, but I didn’t realize it until I was on my way to Berkeley. Ted, could you bring a fully-charged battery to there and double check the battery connections if you are planning to visit the site next week. Thank you.
  3. I removed Gashound Li-800 sn AKC-0479 from the tower site according to Ted’s request and instruction.
  4. Soil surface was still extremely dry. I didn’t see any evident of rain in both sites. Soil moisture measurement was done.
  5. Oak leaves were sampled.

Tonzi_Tower Site

  1. Fence and gate power: >12.0 v.
  2. Panel and Batteries: 13.5 v; 0.0 amps; 3.7 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)
    Time 11:16:28
    Path/File name D:TW4_265.flx
    mean std mean std
    w -0.13 0.576 Ts 26.364 0.175
    u 0.35 1.159 H2O 2.506 0.075
    v -1.55 2.198 CO2 1.618 0.012
  4. Download data.
  5. Remove Gashound Li-800.
    • Unplug power to the pump
    • Unplug power to Li_800
    • Unplug power to the datalogger
    • Close the CO2 and N2 calibration tank.
  6. Close gate and set up fence.

Toniz_Floor Site

  1. Fence and gate power: >12.0 v.
  2. Panel and Batteries: 13.8 v; 14.9 amps; 2.4 amps.
  3. the Floor-site laptop screen didn’t show anything when I got there. After I restarted the laptop twice, the screen started working for me but still flushing all the time. Thus, the Floor-site laptop needs to be replaced soon.
    Time 12:03:02
    Path/File name D:fl4_265.flx
    mean std mean std
    w 0.07 Ts 26.709
    u 0.41 H2O 1.196
    v 0.3 CO2 1.692
  4. Download data, missing D258 – D259.
  5. MD-9 system connections were good, except CR10X7 because the CO2 profile system was shut down today.
  6. The battery in the open site of Soil CO2 profile was 10.986v, lower than normal 12.0v. I reconnected the power line to another good battery. I was not sure whether the batteries were connected to solar panels. I should bring the dead battery back, but I didn’t realize it until I was on my way to Berkeley. Ted, could you bright a fully-charged battery to there and double check the battery connections if you are planning to visit the site next week. Thank you.
  7. Close gate and set up fence.

Field Data

No tank data

No TZ Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

No TZ Tree DBH found

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Explore the graph:Tonzi Tower Met: Temperature and Power in a new window

Explore the graph:Tonzi Tower Met: Solar Radiation in a new window

Explore the graph:Tonzi Tower Met: IRT Sensors in a new window

Explore the graph:LED Sensor Incoming in a new window

Explore the graph:LED Sensor Outgoing in a new window

Explore the graph:4-Band Solar Radiation in a new window

Explore the graph:Air Temperature Profile in a new window

Explore the graph:Relativity Humidity Profile in a new window

Explore the graph:Tonzi Tower PRI in a new window

Explore the graph:SRS PRI/NDVI in a new window

Explore the graph:SRS NDVI in a new window

No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found

Explore the graph:Tonzi PPT in a new window

Explore the graph:Tonzi CO2 and H2O Densities in a new window

Explore the graph:Air Pressure in a new window

No data found for TZ_fflux.
8 TZ_fmet graphs found

Explore the graph:Soil Heat Flux in a new window

Explore the graph:Tonzi Soil Temperature Set A in a new window

Explore the graph:Tonzi Soil Temperatures Set B in a new window

Explore the graph:Tonzi Soil Temperatures Set C in a new window

Explore the graph:Tonzi Soil Temperature Set D in a new window

Explore the graph:Well Level in a new window

Explore the graph:Well Water Temperature in a new window

Explore the graph:Soil Water Potential in a new window

No data found for TZ_tram.
No data found for TZ_co2prof.
No data found for TZ_irt.
1 TZ_windprof graphs found

Explore the graph:Wind Speed Profile in a new window

No data found for TZ_tflux.
2 TZ_sm graphs found

Explore the graph:Floor Solar Radiations in a new window

Explore the graph:TZ Soil Moisture in a new window

Can't check TZ_met
1 TZ_met graphs found

Explore the graph:Floor and Tower RH in a new window

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration