<--2003-01-07 14:00:00 | 2003-01-21 09:00:00-->Phenocam link: Searching...
Vaira: 2003-01-08 00:00:00 (DOY 8)
Author: Ted Hehn
Others:
Summary: Order materials for Jianwu's site.
-8Jan03 -Stop at True value in Jackson and order electric fencer and insulated handles for Jianwu’s site Vaira- Foggy and overcast 8PVM Regulator voltage 11.6 Array current 2.2 Load current 3.3 -check wiring on PVM array: 1PVM=> 11.6, 0.5, 3.3 2PVM=> 11.5, 1.0, 3.3 3PVM=> 11.6, 1.8, 3.3 4PVM => 11.7, 2.3, 3.3 Here is the problem: 4PVMs generate as much current as 8. Check wiring: connection on 5th PVM not correct – connected to wrong terminal. Correct and now getting 7.5 amp under cloudy conditions. This situation (running on 4 modules) has existed from the time the system was installed and we can now expect a major positive shift in site power/run time/data capture. CR10x- open channels: DE 4, 5, 6 MUX- channel 14H1 is stripped and unusable Open channels 14 H2, L2; 15 H1 L1, H2 L2; 16 H1 L1, H2 L2 Cr23x- open channels: DE 9,10, 11 |