Field Notes
<--2017-06-15 09:30:00 | 2017-07-05 10:30:00-->Other sites visited today: Tonzi | Vaira
Phenocam link: Searching...
Tonzi: 2017-06-15 11:30:00 (DOY 166)
Author: Joe Verfaillie
Others: Siyan
Summary: Lost camera card, fix multiplier on Tower W wind, midday water potential, no manual soil moisture due to dead battery, well cable completely rotting
Tonzi 2017-06-15 I arrived about 11:30 with Siyan. It was clear, sunny and hot with a little breeze. The ground and grass are crackly dry. There is still a tiny tinge of green in the low spots and still some flowers. The trees look good. I worked on the tower top trying to fine what setting was causing the W wind to be too high. I copied the configs from both the 7500 and the sonic. I finally found it in the 7500 config file – the multiplier was 6 when it should have been 1. I reset the parameters on the Licor box. Note, the white netbook works well with the sonic coms but the silver one hangs up. In ejecting the CFM card on the CR1000 I dropped it and it disappeared into the grass at the base of the tower. There was camera images and some data from the rotating shadow band on it. The new card would not format. Finally I discovered that the camera was writing files to the card while the data logger was trying to format it and interrupting the process. So I unplugged the camera until the format was complete. I serviced the z-cams and collected the data from the met data loggers and the Floor Licor GHG system. No Moisture Point measurements because the meter had a dead battery. The cable on the Floor well sensor is rotting all the way down. I need to replace it. Siyan did midday water potential. |
Field Data
No tank data
No TZ Well data found
No TZ Moisture Point data found
No VR Moisture Point data found
No TZ grass heigth found
No VR grass heigth found
No TZ Tree DBH found
No water potential data found
No TZ Grass Biomass data found
No TZ OakLeaves Biomass data found
No TZ PineNeedles Biomass data found
2 photos found
20170615TZ_AMPBox.jpg ( 2017-06-15 11:30:57 ) Full size: 1920x1440
New LI-7550 system provided by the Ameriflux Management Project for upgrading the Tonzi/Vaira LI-7500s
20170615TZ_FloorAmpEquip.jpg ( 2017-06-15 12:57:10 ) Full size: 1440x1920
New LI-7550 system provided by the Ameriflux Management Project for upgrading the Tonzi/Vaira LI-7500s
16 sets found
No data found for TZ_Fenergy.
11 TZ_tmet graphs found
11 TZ_soilco2 graphs found
Can't check TZ_mixed
3 TZ_mixed graphs found
1 TZ_fflux graphs found
8 TZ_fmet graphs found
No data found for TZ_tram.
No data found for TZ_co2prof.
1 TZ_irt graphs found
No data found for TZ_windprof.
1 TZ_tflux graphs found
2 TZ_sm graphs found
Can't check TZ_met
1 TZ_met graphs found
Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data