Instrument:Infrared Temperature
Manufacture:Apogee
Model No:SI-121
Serial No:1964
Tag No:
Acquisition Date:2015-04-22
Project:Ameriflux
Location on 2024-04-30:Lab,
Notes: Replacing old SI-121 sensor that was traded in. Narrow field of view 18deg half-angle, 0.6sec response time, analog outs.
Coefficients:
mC2 = 1.19642e5
mC1 = 1.10613e7
mC0 = 1.89441e9
bC2 = 2.67874e3
bC1 = 6.90193e4
bC0 = -1.33937e7

Documents

Calibration: cal_Apogee_SI-121_1964.pdf

History

Rec No.DateLoc FromTitleLoc ToNotes
6694 2024-04-30 Lab none Repair Lab none The cows had chewed the cable very nearly down to the nub. I had to cut some of the strain relief off to get enough conductor to splice. I added a length of cable and then spliced the end on that has a completion resistor for the thermmistor half bridge. So two splices. It compared withing 0.5C with the other IRT in the window - as good as you get without a fancier setup.
6693 2024-04-10 Tonzi Infrared Temperature Grass A Removed Lab none Removed from the IRT tripod at Tonzi where it was pointed at the ground. The cows ate its cable.
1807 2015-05-06 Lab none Installed Tonzi Infrared Temperature Grass A Installed at Tonzi to the east just north of the road. This sensor is point down on a patch of ground cleared of grass.