History for Siemens SP75 020854E-6-03-02-06905
Rec No. | Date | Loc From | Title | Loc To | Notes |
---|---|---|---|---|---|
5820 | 2022-05-04 | Lab none | Repair | Lab none | This panel had been under (salt) water at Yampah. The junction box on the back was all rotted out. I scraped the box off and the four junctions to the two 6V cell strings were still good. I soldered wires to the junction pads and added a screw terminal with two diodes. The panel was 20V and 4.5A in the sun. I cut the structure out of the junction box and reglued it to the back on the panel to protect the wiring and screw terminal. I think this panel is good to go. |
5740 | 2022-03-21 | Loaned none | Returned | Lab none | Returned from temporary setup on the Yampah Marsh at Elkhorn Slough. |
5578 | 2021-11-12 | Lab none | Loaned | Loaned none | Loaned to Adina Paytan at UCSC for temporary setup on the Yampah Marsh at Elkhorn Slough. |
5547 | 2021-10-26 | Vaira Solar Panel SoilCO2-A | Removed | Lab none | Removed from Vaira - not in use, was for old soil co2 system. |
5545 | 2012-02-16 | Lab none | Installed | Vaira Solar Panel SoilCO2-A | Installed to provide 24V power for soil CO2 system but mistakenly wired for 12V - fixed on 3/19 |
5543 | 2012-02-09 | Tonzi Solar Panel Floor G | Removed | Lab none | Removed from the Floor solar system. This panel has not been connected to the system since at least August 2008 |