Equipment and Calibration
View History
Equipment Entry
Instrument: | Solar Controller |
Manufacture: | MorningStar |
Model No: | PS-30M |
Serial No: | 02431248 |
Tag No: | NULL |
Acquisition Date: | 0000-00-00 |
Project: | DOE-TCP |
Location on 2017-06-02: | Lab, NULL |
Notes: |
Dead |
|
|
Documents
No documents found
History
Rec No. | Date | Loc From | Title | Loc To | Notes |
3397 |
2017-06-02 |
Lab none |
Tested |
Lab none |
I tested this controller in the lab and talked with a Morningstar technician. The consensus is that something failed on the board that disabled the load. It might be fine for charging batteries though. |
2220 |
2016-03-08 |
Tonzi-Tower |
Removed |
Lab none |
This charge controller was at the Tonzi Tower. It could not read the battery bank voltage and had shutdown the load with a Low Voltage Disconnect message. I removed it and replaced it with the controller from the Tram system sn 0135002X |