View history entry 3397 for MorningStar PS-30M sn: 02431248

Date: 2017-06-02
From: Lab - none
To: Lab - none
Title: Tested
Notes: I tested this controller in the lab and talked with a Morningstar technician. The consensus is that something failed on the board that disabled the load. It might be fine for charging batteries though.
Entered by: Joe Verfaillie