Equipment and Calibration History
History for MorningStar PS-15M 12501588
Rec No. | Date | Loc From | Title | Loc To | Notes |
---|---|---|---|---|---|
6202 | 2023-03-02 | Lab none | Tested | Disposed none | This charge controller hasn't been showing solar amps. I took it apart and cleaned out a bunch or large dead ants. I found two diodes and one capacitor that looked a little fouled but not obviously broken. I'm not sure I have the tools/skills to do any more. I cleaned it up, put it back together and tested it. Now the screen shows nonsense - different on each power cycle. I think it's a goner. Put it in the e-waste box. |
6210 | 2023-03-01 | Tonzi Solar Controller Soil CO2 | Removed | Lab none | This solar controller has not been showing solar amps and doesn't seem to charge batteries. I brought it in for testing |
4555 | 2020-07-07 | Lab none | Installed | Tonzi none | Installed in the Soil CO2 box under the tree at Tonzi. I swapped out an old 1st gen 30A model sn 186580399. |
4092 | 2019-08-19 | Bouldin Alfalfa-ReleaseEx Solar Controller Near | Removed | Lab none | Removed from the closer (day time) CH4 release point. The secondary tower and farther release point will continue. |
4081 | 2019-08-16 | Lab none | Installed | Bouldin Alfalfa-ReleaseEx Solar Controller Near | Installed for CH4 release experiment. This unit was part of the closer (day time) release point. |
3458 | 2018-05-10 | East Pond Solar Controller Secondary | Removed | Lab none | Removed from East Pond. Replaced by 30A controller. |
3433 | 2018-04-17 | Lab none | Installed | East Pond Solar Controller Secondary | Installed at EP tower as part of initial site set up about 12m NNW of the tower |
3141 | 2017-10-16 | East End-Temp2 Solar Controller | Removed | Lab none | Removed from the East End Temporary Tower #2 - Closed Canopy with the decommissioning of the site. |