5811 | 2022-04-20 | Lab none | Installed | Mayberry none | Installed at MB to replace the 3 Shell solar panels that were removed today to be used for the advection experiment this summer. This panel has been resealed with Qsil and window film. |
5661 | 2022-01-14 | Lab none | Tested | Lab none | This panel has totally crack glass and two big divots. I tested it outside on a clear day. Data from the Delta says max SWin at this time of year is around 500W. Specs on the back say 6.3A at 800W. I got 3.4A. If you do the ratio you get 3.9A at 500W. As tested I did not have an unobstructed view of the sky and cracks in the glass but no shadows on the panel and a reasonable angle. So maybe worth resealing. Use Qsil 216: http://americansolarsupply.com/stores.html#!/QSil-216-Encapsulant/c/12380606/offset=0&sort=normal |
5195 | 2021-03-11 | Hill Slough Solar Panel C | Removed | Lab none | This panel was removed from the lowest position at Hill Slough because its glass face is broken. It was replaced by sn 11ZV0M0828 |
5134 | 2021-02-26 | Sherman Wetland-Temp1 Solar Panel B | Moved | Hill Slough Solar Panel B | Removed from the decommissioned temporary location for use at Hill Slough |
4355 | 2020-01-30 | East Pond Solar Panel B | Moved | Sherman Wetland-Temp1 Solar Panel B | Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower. |
3430 | 2018-04-17 | Lab none | Installed | East Pond Solar Panel B | Installed at EP tower as part of initial site set up about 12m NNW of the tower |
3119 | 2017-10-04 | East End-Temp3 Solar Panel B | Removed | Lab none | Removed with the decommissioning of Temporary Tower #3 - Boardwalk site. |
2885 | 2017-06-23 | Lab none | Installed | East End-Temp3 Solar Panel B | Installed at the East End Temporary Tower #3 Boardwalk location with the initial setup of the site. |
2774 | 2017-05-18 | West Pond Solar Panel A | Removed | Lab none | Removed from West Pond to make way for new 24V system. |
565 | 2012-05-02 | Lab none | Installed | West Pond Solar Panel A | Installed to power the site at West Ponds. The solar panels are on top of one level of scaffolding just inside the edge of the east pond. |