Skip to main content
rice field banner biometlab logo
 

Field Notes

<--2009-03-12 10:00:00 | 2009-03-27 10:00:00-->
Other sites visited today: Tonzi

Tonzi: 2009-03-12 10:00:00 (DOY 71)
Author: Siyan Ma
Others: Joe, Gretchen


When: Date: 3/12/2009 , Day: 71 , Watch Time: 10:00am .
Where: Tonzi/Vaira Ranch
Who: Siyan, Joe, Gretchen
Weather: clear, nice breeze
Phenology: Vaira grass tilering (2-10), Tonzi grass still one stem. See two trees come out leaves: one near Mr. Tonzi’s house; the other one near the gate.
Summary
  1. check and download data at Tower, Floor, and Vaira. Floor site missed some flux data because of lost COM3. Fixed by Joe.
  2. grass sample for LAI and phenology in Tower and Vaira, oak branches for N
  3. soil moisture
  4. dendrometer
  5. spectrometer

Vaira_Grass Site
  1. Fence and gate power: 12 v.
  2. Panel and Batteries: 13.9 v; 10.8 amps; 2.7 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\V09_ 71 .flx
D:\Data\VR09 .raw


mean

std


mean

std

w

-0.11

0.22

Ts

13.

1.32

u

0.67

0.37

H2O

2.2

0.19

v

0.81

0.3

CO2

1.83

0.21




couple

1.83

spiky
  1. downloading data YES!
  2. check the fans of air temp. and relative humidity sensors at Vaira. YES!
  3. Check MD-9 system connections YES!
  4. Check CR23X with two multiplexers

Sys_vot = 14.2
PC_start =
  1. Check levels of Radiation sensors, clear up surfaces. YES!

9. Closed gate and set up fence. YES!

Tonzi_Tower Site

  1. Fence and gate power: 12 v.
  2. Panel and Batteries: 13.1 v; 0.0 amps; 5.0 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\T09_ 71 .flx
D:\Data\TW069 .raw


mean

std


mean

std

w

-0.26

0.289

Ts

13.2

0.647

u

0.71

0.239

H2O

1.19

0.023

v

0.79

0.710

CO2

2.33

0.024
  1. downloading data YES!
  2. check the fans of air temp. and relative humidity sensors on the tower and the floor. YES!
  3. Check calibration cylinders;

CO2 1800 psig; flow 20 psi.
N2 1250 psig; flow 20 psi.
Manually calibrate Li-800. Following Ted’s instruction: YES!
H:\IoneSavanna_2004\Tower_2004\CO2Profile\LI800_Calibration_Procedure_2Nov04.txt
Is the pump running‌ YES!

402

401

402

401

0.73

427

946

943

940

939

947

946

44

44

44.6

44

43

44

50.9

50.8

50.9

50

50

50


  1. close gate and set up fence. YES!

Toniz_Floor Site
  1. Fence and gate power: 12 v.
  2. Panel and Batteries: 13.0 v; 15.2 amps; 1.9 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\F09_ .flx
D:\Data\FL09 .raw


mean

std


mean

std

w

-0.20

0.242

Ts

13.9

0.849

u

-0.03

0.512

H2O

2.3

0.198

v

1.51

1.173

CO2

1.94

0.148
  1. downloading data YES!
  2. Check MD-9 system connections

CR23X3 – floor-Met
CR23X5 – soil CO2 profile YES!
CR23X6 – tower-Met
CR10X2 – floor-Met
CR10X4 – sap-flow
CR10X7 – CO2 profile
  1. Soil CO2 profile

Reading from datalogger

Panel temp

17.9



Battery voltage

13.4



CO2E_1

921

TCE_1

13.5

CO2W_1

1890

TCW_1

15.7

CO2E_2

967

TCE_2

16.0

CO2W_2

2824

TCW_2

13.3

CO2E_3

2706

TCE_3

17.0

CO2W_3

3393

TCW_3

18.6

CO2E_4

2640

TCE_4

10.3

CO2W_4

3093

TCW_4

12.1

Reading from panels of analyzers

depth

Open

order

depth

Tree

order

2cm (1%)

1870

1

2cm (1%)

3730

1

4cm

1970

2

4cm

5260

4

8cm

5440

3

8cm

6898

2

16cm

1.06%

4

16cm

4.06%

3
  1. Close gate and set up fence. YES!

Tonzi




Dendrometer







Date

Day

Tag #

Reading (cm)

3/21/2009

71

71

x



72

13.0



77

Broken



78

Broken



79

17.3



245

6.0



248

X



250

14.6



255

X



‌252‌

missing



102

8.2





Gretchen’s group dendrometers
My No.
1. 9.9
2. 11.7
3. 12.7
3.6
4. 12.7
5. 8.3
6. 10.3

Field Data

No tank data

Well Depth

DateLocationDepth (feet)
2009-03-12TZ_floor27.61
2009-03-12TZ_road33.97
2009-03-12TZ_tower31.58

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

11 TZ_soilco2 graphs found

Tonzi Soil CO2 Profile: Open (East) CO2

Tonzi Soil CO2 Profile: Tree (West) CO2

Tonzi Soil CO2 Profile: Open (East) Temperatures

Tonzi Soil CO2 Profile: Tree (West) Temperatures

Tonzi Soil CO2 Profile: Upper CO2

Tonzi Soil CO2 Profile: Lower CO2

Tonzi Soil CO2 Profile: Upper Temperatures

Tonzi Soil CO2 Profile: Lower Temperatures

Tonzi Soil CO2 Profile: Power and Temperature

Tree 2 Soil CO2

Tree 2 Soil Temperature

Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

No data found for TZ_fflux.
8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

1 TZ_tram graphs found

Tonzi Tram Incoming PAR

3 TZ_co2prof graphs found

Tower CO2 Profile Concentrations

Tower CO2 Profile Cell Pressure

CO2 Profile Sensor Temperature

No data found for TZ_irt.
No data found for TZ_windprof.
No data found for TZ_tflux.
2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met
1 TZ_met graphs found

Floor and Tower RH

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration

Login

Select Notes: