When: Date: 2/27/2009 , Day: 58 , Watch Time: .
Where: Tonzi/Vaira Ranch
Who: Siyan, Joe, Dennis, Hideki, Gretchen
Weather: clear
Phenology: green grass, Mr. Tonzi’s pond had more water after good rains.
Summary
  1. check BOOM at Vaira: Dennis’s GPS - north
  2. checked and downloaded data from Tower, Floor, and Vaira
  3. swapped Li-7500 at the three towers
  4. calibrated Li-800 in the field. Bump reinstalled.
  5. Joe installed gray panel for the phenology camera.
  6. Joe installed “surface temperature” sensor on the tower. Tower met program is changed. Need to adapt to Flux processing program.
  7. collected grass sample for LAI
  8. read dendrometers
  9. Dennis took measurements of soil moisture probes.
  10. spectrometer
  11. camera

Vaira_Grass Site
  1. Fence and gate power: OK v.
  2. Panel and Batteries: OK v; OK amps; OK amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\V09_ 058 .flx
D:\Data\VR09 .raw


mean

std


mean

std

w

0.58

0.81

Ts

17.3

0.17

u

0.61

0.63

H2O

2.0

0.03

v

1.88

0.68

CO2

2.0

0.382




Tc

1.4

-
  1. downloading data YES!
  2. swaping Li-7500 Analyzer. (Remove SN# 41 ; install SN# 65 )
  3. Check the fans of air temp. and relative humidity sensors at Vaira. YES!
  4. Check MD-9 system connections: YES!
  5. Check CR23X with two multiplexers

Sys_vot = 13.21
  1. Check levels of Radiation sensors, clear up surfaces. YES!
  2. Check rain gage, make sure not clogged. YES!
  3. Closed gate and set up fence. YES!

Tonzi_Tower Site

  1. Fence and gate power: OK v.
  2. Panel and Batteries: 13.5 v; 0.0 amps; 4.4 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\T09_58 .flx
D:\Data\TW09 .raw


mean

std


mean

std

w

-0.57

0.444

Ts

11.7

0.182

u

-2.15

1.064

H2O

0.78

0.018

v

1.40

0.378

CO2

2.0

0.009
  1. downloading data YES!
  2. swaping Li-7500 Analyzer. (Remove SN# 73 ; install SN# 418 )
  3. check the fans of air temp. and relative humidity sensors on the tower and the floor. YES!
  4. Check rain gage, make sure not clogged. YES!
  5. Check calibration cylinders;

CO2 2000 psig; flow 20 psi. (New tank: 431.25ppm)
N2 psig; flow psi.
Manually calibrate Li-800. Following Ted’s instruction: YES!
H:\IoneSavanna_2004\Tower_2004\CO2Profile\LI800_Calibration_Procedure_2Nov04.txt
Is the pump running‌ Fixed and reinstalled by Joe.
How to check the CO2 values‌ Click “Ports/Flags” button to see which ports or flags is setting high. Pressure should be less than ambient value. When Flag 8 is high, it may indicate that RRR’s battery is low.
  1. close gate and set up fence. YES!

Toniz_Floor Site
  1. Fence and gate power: OK v.
  2. Panel and Batteries: OK v; amps; amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\F09_ 58 .flx
D:\Data\FL09 .raw


mean

std


mean

std

w

0.04

0.23

Ts

13.1

0.998

u

-0.76

0.38

H2O

2.4

0.218

v

-0.02

0.4

CO2

2.07

0.013
  1. downloading data YES!
  2. swaping Li-7500 Analyzer. (Remove SN# 976 ; install SN# 35 )
  3. Check MD-9 system connections YES!

CR23X3 – floor-Met
CR23X5 – soil CO2 profile YES!
CR23X6 – tower-Met
CR10X2 – floor-Met
CR10X4 – sap-flow
CR10X7 – CO2 profile
CR10X8 – wind profile
  1. Soil CO2 profile

Reading from datalogger

Panel temp

19.3



Battery voltage

13.4



CO2E_1

826

TCE_1

15.4

CO2W_1

1314

TCW_1

16.4

CO2E_2

857

TCE_2

18.7

CO2W_2

1538

TCW_2

14.4

CO2E_3

2027

TCE_3

13.7

CO2W_3

1879

TCW_3

18.7

CO2E_4

2839

TCE_4

11.7

CO2W_4

3093

TCW_4

13.1

Reading from panels of analyzers

depth

Open

order

depth

Tree

order

2cm (1%)


1

2cm (1%)


1

4cm


2

4cm


4

8cm


3

8cm


2

16cm


4

16cm


3
  1. Close gate and set up fence. YES!

Tonzi




Dendrometer







Date

Day

Tag #

Reading (mm)

2/27/2009

58

71

X



72

12.9



77

X



78

X



79

17.5



245

6.0



248

X



250

15.0



255

X



‌252‌

X



102

8.4

Notes: “X” means not working any more.
Dendrometers installed by Gretchen group: Gretchen had the data.

tonzi

7931AFE

402165

574B4B

402FF3

574632

7A432E

7A3C6E

7A3B40

7A4AAA

27-Feb-09

57










SM









0-15

40.6

21.7

46.7

33.9

43.0

37.2

31.5

28.5

19.6

15-30

41.5

45.3

41.7

37.5

40.8

31.8

30.8

33.3

26.0

30-45

39.1

43.3

43.0

41.9

48.7

34.7

33.1

33.7

36.4

45-60

41.6

55.8

61.3

42.6

41.4

34.4

44.2

47.4

37.9












A6D882B

A3D04E8

A6D72F5

















0-15

30.7

32.8

26.5







15-30

31.7

33.8

38.6







30-45

40.5

37.8

40.1







45-60

41.5

51.3

41.4

















vaira

57318a

7933dee








0-15

21.4

27.6








15-30

28.2

32.0








30-45

28.8

37.1








45-60

37.5

36.3








Field Data

No tank data

Well Depth

DateLocationDepth (feet)
2009-02-27TZ_floor30.12
2009-02-27TZ_road36.26
2009-02-27TZ_tower34.72

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)
2009-02-27110.3
2009-02-271028.3
2009-02-2728.5
2009-02-272456.1
2009-02-2725015.1
2009-02-27312.6
2009-02-2743.9
2009-02-27510.4
2009-02-2766.2
2009-02-27711.6
2009-02-277212.9
2009-02-277917.4
2009-02-27812.8

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

2 photos found

Serial Numbers on new Apogee IR surface temperature sensors.  Hand written one is wrong.
20090227TZ_ApogeeSerialNos.jpg ( 2009-02-27 14:39:38 ) Full size: 2048x1536
Serial Numbers on new Apogee IR surface temperature sensors. Hand written one is wrong.

Serial numbers an wiring of new Apogee IR surface temperature sensors.
20090227TZ_23xWiring.jpg ( 2009-02-27 14:40:12 ) Full size: 2048x1536
Serial numbers an wiring of new Apogee IR surface temperature sensors.

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

11 TZ_soilco2 graphs found

Tonzi Soil CO2 Profile: Open (East) CO2

Tonzi Soil CO2 Profile: Tree (West) CO2

Tonzi Soil CO2 Profile: Open (East) Temperatures

Tonzi Soil CO2 Profile: Tree (West) Temperatures

Tonzi Soil CO2 Profile: Upper CO2

Tonzi Soil CO2 Profile: Lower CO2

Tonzi Soil CO2 Profile: Upper Temperatures

Tonzi Soil CO2 Profile: Lower Temperatures

Tonzi Soil CO2 Profile: Power and Temperature

Tree 2 Soil CO2

Tree 2 Soil Temperature

Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

No data found for TZ_fflux.
8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

No data found for TZ_tram.
3 TZ_co2prof graphs found

Tower CO2 Profile Concentrations

Tower CO2 Profile Cell Pressure

CO2 Profile Sensor Temperature

No data found for TZ_irt.
No data found for TZ_windprof.
No data found for TZ_tflux.
2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met
1 TZ_met graphs found

Floor and Tower RH

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.