Field Notes

<--2009-09-17 07:30:00 | 2009-10-09 10:30:00-->
Other sites visited today: Twitchell Rice
Phenocam link: Searching...

Sherman Island: 2009-10-06 09:30:00 (DOY 279)
Author: Joe Verfaillie
Others:

Summary: Computer crashed. Swapped main tower instruments to CR1000. Collect all from data loggers, cleared bug from LGR 40um filter, rough measurements of site.

Sherman
10-6-2009

Arrived about 9:30am PDT. Clear, cool, light breeze out of the north. Field is wet to the west and north, north ditch full, middle ditch west end full. Trucks running past field and to south, but seems they wetted the roads so dust is not too bad.

The computer had crashed and would not reboot, giving a disk error. Everything else seems okay. I used my laptop to connect to each data logger and down loaded all the internal data from each. Then I reconfigured things so that the main tower runs on the CR1000 and the sonic and IRGA on the tripod are not being recorded. I changed the main sonic setting from:

B2 E1 F1 G1 J3 J5 L1 M7 NA O1 P6 U1 Z1 X1

To:

B5 E1 F1 G1 J0 J5 L1 M1 NA O2 P6 U1 Z1 X1

I moved the LI7500 SDM cable from the tripod tower to the main tower.

I disconnected the computer and brought it in for repair.

I swapped the cards on the CR1000.

All data (minus the tripod tower) should be recorded as long as the data logger’s internal memory holds out. This should be weeks for all but the fast radiation CR10X which should last about a week. The web cam will not be recorded until the computer is replaced.

I cleaned the radiation sensors (not very dirty) and checked the tipping bucket (clear).

There was a bug stuck in the 40um filter pressure was 126. After bug cleared LGR data:

9:29, 23.74C, 142.51Torr, 17.659usec, 2.026ppm

I looked around for LGR trailer logistics and tower location in the northern part of the field. The northern ditch makes it impossible to get a vehicle into the northern third of the field from the south. There is a driveway down off the levee to the north and a gate. Both are overgrown with vegetation, but could be cleared and probably used to get access to the northern third of the field.

Main power at the site is 100A. Two 20A breakers are in place. Turning off the main breaker will allow the installation of a third breaker for the LGR trailer. The distance from the power pole to the fenced area is about 18 feet. I accidentally flipped the main 100A breaker, systems came back up just fine on reset.

The fenced area has these dimensions

Diagram of Sherman Pasture site dimensions

0 photos found

Graphs display:
7 sets found

No data found for SI_mp.
10 SI_met graphs found

Explore the graph:Solar Radiation in a new window

Explore the graph:Energy in a new window

Explore the graph:Soil Temperatures Set 1 in a new window

Explore the graph:Soil Temperatures Set 2 in a new window

Explore the graph:Soil Temperatures Set 3 in a new window

Explore the graph:Soil Temperature at -16cm in a new window

Explore the graph:Solar Radiation from CNR1 in a new window

Explore the graph:Sherman Island Rain in a new window

Explore the graph:Sherman Well Level in a new window

Explore the graph:Box Temperatures in a new window

Can't check SI_mixed
2 SI_mixed graphs found

Explore the graph:Theta Probes in a new window

Explore the graph:Sherman Island Air Temperatures in a new window

4 SI_flx graphs found

Explore the graph:Sonic Wind in a new window

Explore the graph:CH4 Concentrations in a new window

Explore the graph:Sample Counts in a new window

Explore the graph:LI7500 CO2 and H2O in a new window

No data found for SI_soilco2.
Can't check TWSI_mixed
Can't check SIMBTWEE_met