Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Field Notes

<--2005-12-19 00:00:00 | 2006-01-10 11:00:00-->

Tonzi: 2005-12-29 10:20:00 (DOY 363)
Author: Siyan Ma
Others:


When: Date: 12/29/2005 , Day: 363 , Watch Time: 10:20 .
Where: Tonzi/Vaira Ranch
Who: Siyan, DDB
Weather high overcast all day, breeze, foggy in Sacramento area,
Phenology green grass, oak leave fell
Summary
  1. Primary CO2 “god” bottle in field. Please bring into town. CO2 value are worn off.
  2. At Vaira, CR communication not working, interrupt downloading – Maybe because of “WET”‌
  3. At Vaira, couldn’t check system and PC voltage because datalogger showed “BUSY IN COM”.
  4. At Vaira, 2 signal of NDVI are negative.
  5. At Tower, Camera didn’t work.
  6. At Floor, couldn’t download data. Something wrong with the connection between computer and screen. Computer can boot up when disconnect the screen, and computer worked sometimes if keep it vertical position with the connection.

Vaira_Grass Site
  1. Fence and gate power: >12 v.
  2. Panel and Batteries: 12.6 v; 8.2 amps; 2.9 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time

10:35:06

Path/File name

D:\Data\V05_363.flx
D:\Data\VR053831030.raw


mean

std


mean

std

w

0.150

0.16

Ts

13.411

0.329

u

1.12

0.248

H2O

2.351

0.056

v

0.5

0.434

CO2

2.255

0.026
  1. downloading data
  2. check the fans of air temp. and relative humidity sensors at Vaira.
  3. Check MD-9 system connections – CR communication not working, interrupt downloading – Maybe because of “WET”‌
  4. couldn’t check system and PC voltage because datalogger showed “BUSY IN COM”.
  5. 2 signal of NDVI are negative.
  6. Rain washed radiation sensors clean.
  7. Closed gate and set up fence.
  8. Spectrometer measurement: took 4 readings

Tonzi_Tower Site

  1. Fence and gate power: >12 v.
  2. No Power when we got here. Dennis restarted the power.
  3. Panel and Batteries: 12 v; 0 amps; 6.7 amps.
  4. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time

11:41:19

Path/File name

D:\Data\T05_363.flx
D:\Data\TW053631130.raw


mean

std


mean

std

w

0.380

0.765

Ts

13.613

0.923

u

0.79

0.582

H2O

2.361

0.192

v

0.1

0.647

CO2

2.147

0.066
  1. downloading
  2. Camera didn’t work.
  3. check the fans of air temp. and relative humidity sensors on the tower and the floor.
  4. Dennis checked CO2 profile system. [CO2]~=400ppm, it is high!
  5. close gate and set up fence.


Toniz_Floor Site
  1. Fence was fixed by DDB.
  2. Panel and Batteries: 12.0 v; 5.8 amps; 2.5 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time

11:36:24

Path/File name

D:\Data\F05_363.flx
D:\Data\FL053630931.raw


mean

std


mean

std

w

0.180

0.15

Ts

14.001

0.235

u

-0.2

0.482

H2O

2.271

0.028

v

0.290

0.347

CO2

2.362

0.056
  1. couldn’t download data. Something wrong with the connection between computer and screen. Computer can boot up when disconnect the screen, and computer worked sometimes if keep it vertical position with the connection.
  2. Soil CO2 profile

Reading from datalogger

Panel temp

13.6



Battery voltage

13.3



CO2E_1

3595.1

TCE_1

12.6

CO2W_1

1567

TCW_1

12.9

CO2E_2

1408.9

TCE_2

13.6

CO2W_2

2375.4

TCW_2

12.6

CO2E_3

1437.6

TCE_3

11.96

CO2W_3

3985.5

TCW_3

12.9

CO2E_4

436.9

TCE_4

11.29

CO2W_4

4709.4

TCW_4

12.6
  1. CO2 profile (Dennis made some notes, please see detail in original notesheet.)
  2. Close gate and set up fence.


Tonzi




Dendrometer







Date

Day

Tag #

Reading (cm)

12/29/2005

363

71

22.5



72

23.3



77

Broken



78

Broken



79

23



245

20.5



248

24.2



250

21.9



255

23.9



‌252‌

missing



102

Broken


tonzi

7931AFE

402165

574B4B

402FF3

574632

7A432E

7A3C6E

7A3B40

7A4AAA

D363










29-Dec-05

SM,DDB









0-15

42.6

38.4

40.7

24.6

39.2

31.2

24.4

26.9

21.9

15-30

37.1

39.9

34.7

40.4

37.6

39.5

29.9

33.4

24.9

30-45

36.6

41.2

40.0

36.7

43.5

34.1

31.5

30.5

36.8

45-60

39.6

52.9

45.1

41.6

39.3

33.0

43.5

43.6

35.8












A6D882B

A3D04E8

A6D72F5

















0-15

34.7

31.9

23.3







15-30

32.9

34.9

33.9







30-45

34.3

33.6

34.7







45-60

41.1

46.9

44.3

















vaira

57318a

7933dee








0-15

18.0

11.1








15-30

28.4

37.1








30-45

30.4

36.2








45-60

31.8

33.1









Sample vial

What

MIBA-US-01.__-__

Leave 1

MIBA-US-01.__-__

Leave 2

MIBA-US-01. _131___

Grass 1

MIBA-US-01. __132__

Grass 2

MIBA-US-01. __133__

Surface Litter

MIBA-US-01. __134__

Soil in 10 cm

MIBA-US-01. _135___

Stem 1

MIBA-US-01. __136__

Stem 2

Field Data

No tank data

No TZ Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

No data found for TZ_fflux.
8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

No data found for TZ_tram.
No data found for TZ_co2prof.
No data found for TZ_irt.
1 TZ_windprof graphs found

Wind Speed Profile

No data found for TZ_tflux.
2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met
1 TZ_met graphs found

Floor and Tower RH

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.