Field Notes

<--2010-02-25 09:00:00 | 2010-03-16 09:00:00-->

Tonzi: 2010-03-05 09:50:00 (DOY 64)
Author: Siyan Ma
Others:


When: Date: 3/5/2010 , Day: 63 , Watch Time: 9:50 am .
Where: Tonzi/Vaira Ranch
Who: Siyan
Weather: partially cloudy
Phenology: green grass, oak leaves about coming out, wet

Tonzi

Leaves of the tree by the side of Mr. Tonzi’s house were just out. Other trees hadn’t yet.

Mr. Tonzi’s pond was full.



Vaira:





(The date on the photos should be 2010/03/05.)


Summary
  1. The aspiring bump for Vaira Ta&Rh didn’t work. I clicked it, and it worked again, but not very strong.
  2. checked and downloaded data at Tower, Floor, and Vaira
  3. swapped Li-7500 at Tower and Floor site.
  4. returned the TRAM to the field.
  5. returned the Soil CO2 probes to the field.
  6. Didn’t calibrate Li-800 in the field because the CO2 profile system was off for power saving purpose.
  7. collected grass samples for LAI
  8. dendrometers
  9. soil moisture
  10. groundwater well:

Date

DOY

Location

Depth - no black thing (feet)

3/5/2010

63

Floor

25.4



Tower

29.61



roadside

32.86

Vaira_Grass Site
  1. Fence and gate power: 12 v.
  2. Panel and Batteries: 13.8 v; 14.4 amps; 3.7 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

  1. downloading data YES!
  2. Check the fans of air temp. and relative humidity sensors at Vaira. YES!
  3. Check MD-9 system connections YES!
  4. Check CR23X with two multiplexers

  1. Check levels of Radiation sensors, clear up surfaces.YES!
  2. Check rain gage, make sure not clogged. YES!
  3. Closed gate and set up fence. YES!

Tonzi_Tower Site

  1. Fence and gate power: 12 v.
  2. Panel and Batteries: v; amps; amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

  1. downloading data YES!
  2. swap IRGA: remove #418; install #976.
  3. check the fans of air temp. and relative humidity sensors on the tower and the floor. YES!
  4. Check rain gage, make sure not clogged. YES!
  5. Check calibration cylinders;

The whole system is off for saving power.
  1. close gate and set up fence. YES!

Toniz_Floor Site
  1. Fence and gate power: 12 v.
  2. Panel and Batteries: 14.9 v; 12.8 amps; 1.9 amps. (about 7:00 am local time)
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

  1. downloading data YES!
  2. swap IRGA: remove #73; install #1594.
  3. Check MD-9 system connections YES!

CR23X5 – soil CO2 profile
Put CO2 probes back after Jacyln did comparison in the lab.
Reset power, but indicator showed “battery low”. LOOKS OK!


CR23X6 – tower-Met

CR10X2 – floor-Met

CR23X3
  1. Soil CO2 profile: no power when I got there. I unplug and re-plug fuses, then the system back to work.

Reading from datalogger
Reading from panels of analyzers
Read after installation, might not be balanced.

depth

Open

order

depth

Tree

order

2cm (1%)

570

1

2cm (1%)

1040

1

4cm

1020

2

4cm

1820

4

8cm

830

3

8cm

1380

2

16cm

370

4

16cm

540

3
  1. Close gate and set up fence. YES!

tonzi

7931AFE

402165

574B4B

402FF3

574632

7A432E

7A3C6E

7A3B40

7A4AAA

3/5/2010

63










DDB









0-15

46.4

26.1

39.9

37.9

38.4

39.6

30.5

29.1

22.9

15-30

41.1

45.7

46.3

39.8

40.8

40.2

30.7

35.3

31.0

30-45

39.6

46.0

90.2

41.6

44.1

35.4

34.1

34.3

37.7

45-60

39.1

56.0

80.4

45.4

42.0

35.7

44.0

47.7

38.8












A6D882B

A3D04E8

A6D72F5

















0-15

38.7

35.2

28.5







15-30

33.2

39.0

39.6







30-45

37.4

36.8

44.6







45-60

45.4

51.7

45.1

















vaira

57318a

7933dee








0-15

27.2

28.6








15-30

32.4

29.2








30-45

31.6

36.7








45-60

33.9

34.3










Tonzi






Dendrometer











Date

Day

Tag #

Reading (mm)



3/5/2010

63

72

7.2





79

10.9





102

X





245

10.4





250

21.2

(reset to 10.5 on May 7, 2009)




1

17.5





2

10.1





3

16.5





4

7





5

11.5





7

15.2

133




8

15.4

11828




71

X





77

X





78

X





248

X

broken




255

X





‌252‌

X





6

X



Notes: “X” means not working any more.
Dendrometers installed by Gretchen group

Field Data

No tank data

Well Depth

DateLocationDepth (feet)
2010-03-05TZ_floor25.4
2010-03-05TZ_road32.86
2010-03-05TZ_tower29.61

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

11 TZ_soilco2 graphs found

Tonzi Soil CO2 Profile: Open (East) CO2

Tonzi Soil CO2 Profile: Tree (West) CO2

Tonzi Soil CO2 Profile: Open (East) Temperatures

Tonzi Soil CO2 Profile: Tree (West) Temperatures

Tonzi Soil CO2 Profile: Upper CO2

Tonzi Soil CO2 Profile: Lower CO2

Tonzi Soil CO2 Profile: Upper Temperatures

Tonzi Soil CO2 Profile: Lower Temperatures

Tonzi Soil CO2 Profile: Power and Temperature

Tree 2 Soil CO2

Tree 2 Soil Temperature

Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

No data found for TZ_fflux.
8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

1 TZ_tram graphs found

Tonzi Tram Incoming PAR

3 TZ_co2prof graphs found

Tower CO2 Profile Concentrations

Tower CO2 Profile Cell Pressure

CO2 Profile Sensor Temperature

No data found for TZ_irt.
No data found for TZ_windprof.
No data found for TZ_tflux.
2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met
1 TZ_met graphs found

Floor and Tower RH

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration

 
 