Field Notes
<--2004-07-21 11:39:00 |
2004-08-17 10:30:00-->
Other sites visited today:
Vaira
Phenocam link:
Searching...Tonzi: 2004-08-05 09:41:00 (DOY 218)
Author: Siyan Ma
Others: Dennis, Qi, Lorraine
Summary: Soil samples for bulk density and moisture, leaf samples, set up Floor regeneration study
When: Date: Aug. 5, 2004, Day: 218, Watch Time: 10:30 am Where: Tonzi/Vaira Ranch Who: Dennis, Siyan, Qi, Lorraine Weather: Sunny, nice, warm but not hot, breeze Phenology: dead grass
Summary
- Overall EC systems were running well. Data were downloaded
- Today was the first time to download Vaira’s CR23X (gr3*.23x) data after Ted re-set up the new program with two multiplexers. CG1_UP (longwave_incoming) = -1.13, maybe need switch wirings.
- Dennis replaced MD9_x.exe files to fix the problem of file naming. Be sure to rename the two files with the same name next time.
- Dennis and Lorraine took soil bulk density and moisture samples.
- Leaf samples were taken from the trees with Tag 222, 225,227,228, and 33. Those trees were marked by flaggings.
- Siyan set up 30 flags around floor site for regeneration study.
Tonzi_Tower Site
- Fence and gate power: >12.0 v.
- Panel and Batteries: 13.3 v; 0.0 amps; 4.7 amps.
- Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)
Time |
9:41:30 |
Path/File name |
TW4-218.flx left 1023MB |
|
mean |
std |
|
mean |
std |
w |
0.15 |
0.489 |
Ts |
28.299 |
0.619 |
u |
2.23 |
0.684 |
H2O |
2.388 |
0.038 |
v |
0.42 |
0.751 |
CO2 |
1.46 |
0.01 |
- Download data. (Alt_X to close Gillsonic.exe; close PC208W before copying.) After download data Gillsonic was frozen again. Dennis turned off the power for about 1 minute, and then it works. Reading from Gillsonic screen after downloading data looks good.
- Check calibration cylinders;
CO2 2000 psig; flow 1.6 psi. N2 900 psig; flow 10.0 psi.
- CO2 profile looks OK from Floor PC, but cell temperature was 30oC instead of 50oC. Manually calibrate Li-800 was not done.
- Dennis climbed the tower and cleaned up the sensors.
- Checking CR10X and CR23X:
CR10X OK. CR23X – NR_2 = -9999.
Tonzi_Floor Site
- Fence and gate power: >12.0 v.
- Panel and Batteries: 13.7 v; 15.8 amps; 2.3 amps.
- Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)
Time |
10:23:19 |
Path/File name |
FL4_218.flx |
|
mean |
std |
|
mean |
std |
w |
0.56 |
0.229 |
Ts |
29.129 |
0.697 |
u |
-0.27 |
0.667 |
H2O |
2.364 |
0.004 |
v |
1.33 |
0.35 |
CO2 |
1.541 |
0.016 |
- Readings were OK from Gillsonic screen after downloading
- Check MD-9 system connections. Dennis replaced MD9_x.exe programs.
- Close gate and set up fence.
|
Field Data
No tank data
No TZ Well data found
No TZ Moisture Point data found
No VR Moisture Point data found
No TZ grass heigth found
No VR grass heigth found
No TZ Tree DBH found
No water potential data found
No TZ Grass Biomass data found
No TZ OakLeaves Biomass data found
No TZ PineNeedles Biomass data found
0 photos found
16 sets found
No data found for TZ_Fenergy.
11 TZ_tmet graphs found
No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found
No data found for TZ_fflux.
8 TZ_fmet graphs found
No data found for TZ_tram.
No data found for TZ_co2prof.
No data found for TZ_irt.
1 TZ_windprof graphs found
No data found for TZ_tflux.
2 TZ_sm graphs found
Can't check TZ_met
1 TZ_met graphs found
Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data