Skip to main content
rice field banner biometlab logo
 

Field Notes

<--2007-08-12 17:30:00 | 2007-08-31 17:40:00-->

Tonzi: 2007-08-23 10:30:00 (DOY 235)
Author: Siyan Ma
Others: Stefania


When: Date: 8/23/2007 , Day: 235 , Watch Time: 10:30am .
Where: Tonzi/Vaira Ranch
Who: Siyan, Stefania
Weather: clear, hot, nice breeze
Phenology: leaves of oak tree started to turn to brown, depended on the locations. For many small trees, more than >80% leaves looked brown. For big trees, brown leaves < 10%. Looks like brown leaves appeared around Aug. 10th have fallen off.
Summary
  1. N2 tank is very low.
  2. Swapped Li-7500 on Tower. H2O channel still around 3.0 volts.
  3. Downloaded data at Tower, Floor, and Vaira. Three EC systems worked well.
  4. Helped Stefania collecting leaf samples for sugar isotope.
  5. Took spectrometer measurement at Vaira.
  6. Couldn’t make TDR probe measurement maybe due to bad connections between cable and TDR machine.

Vaira_Grass Site
  1. Fence and gate power: 12 v.
  2. Panel and Batteries: 12.7 v; 5.8 amps; 3.4 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\V07_ 235 .flx
D:\Data\VR07 .raw


mean

std


mean

std

w

0.23

0.287

Ts

41.7

1.06

u

-0.44

1.316

H2O

2.19

0.108

v

0.77

1.008

CO2

1.369

0.015




Tc

3.907

0.102
  1. downloading data
  2. check the fans of air temp. and relative humidity sensors at Vaira. OK.
  3. Check MD-9 system connections. OK.
  4. Check levels of Radiation sensors, clear up surfaces. Yes.
  5. Closed gate and set up fence.

Tonzi_Tower Site

  1. Fence and gate power: No Fence On v.
  2. Panel and Batteries: 13.2 v; 0.0 amps; 6.5 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\T07_ 235 .flx
D:\Data\TW07 .raw


mean

std


mean

std

w

1.22

0.68

Ts

33.9

2.5

u

1.29

0.04

H2O

3.936

0.234

v

1.0

0.92

CO2

1.413

0.078
  1. downloading data
  2. swaping Li-7500 Analyzer. (Remove SN# 976 ; install SN# 418 )
  3. check the fans of air temp. and relative humidity sensors on the tower and the floor.
  4. Check calibration cylinders;

CO2 800 psig; flow 20 psi.
N2 150 psig; flow 20 psi.
Manually calibrate Li-800. Following Ted’s instruction: H:\IoneSavanna_2004\Tower_2004\CO2Profile\LI800_Calibration_Procedure_2Nov04.txt
Is the pump running‌
How to check the CO2 values‌ Click “Ports/Flags” button to see which ports or flags is setting high. Pressure should be less than ambient value. When Flag 8 is high, it may indicate that RRR’s battery is low.
  1. close gate and set up fence. OK.

Toniz_Floor Site
  1. Fence and gate power: 12 v.
  2. Panel and Batteries: 12.9 v; 4.3 amps; 2.1 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\F07_ 235 .flx
D:\Data\FL07 .raw


mean

std


mean

std

w



Ts



u



H2O



v



CO2


  1. downloading data
  2. Check MD-9 system connections. OK.
  3. CR10X7 – CO2 profile

383.8

382.0

383.5

382.7

928.7

928.8

928.8

928.6

48.5

48.35

48.3

48.4

50.7

50.7

50.8

50.8


-0.936

396.0

933.14

928.7

44.7

45.09

49.5

49.5



CR10X8 – wind profile
  1. Soil CO2 profile: probes are in the lab for calibration.
  2. Close gate and set up fence. Yes.



Field Data

No tank data

No TZ Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

No data found for TZ_fflux.
8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

No data found for TZ_tram.
3 TZ_co2prof graphs found

Tower CO2 Profile Concentrations

Tower CO2 Profile Cell Pressure

CO2 Profile Sensor Temperature

No data found for TZ_irt.
1 TZ_windprof graphs found

Wind Speed Profile

No data found for TZ_tflux.
2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met
1 TZ_met graphs found

Floor and Tower RH

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration

Login

Select Notes: