Field Notes
<--2007-08-12 17:30:00 |
2007-08-31 17:40:00-->
Phenocam link:
Searching...Tonzi: 2007-08-23 10:30:00 (DOY 235)
Author: Siyan Ma
Others: Stefania
When: Date: 8/23/2007 ,
Day: 235 ,
Watch Time: 10:30am .
Where: Tonzi/Vaira Ranch
Who: Siyan, Stefania
Weather:
clear, hot, nice breeze
Phenology:
leaves of oak tree started to turn to brown, depended on the locations. For many small trees, more than >80%
leaves looked brown. For big trees,
brown leaves < 10%. Looks like brown
leaves appeared around Aug. 10th
have fallen off.
Summary
- N2 tank is very low.
- Swapped Li-7500 on Tower. H2O channel still around 3.0 volts.
- Downloaded data at Tower,
Floor, and Vaira. Three EC systems
worked well.
- Helped Stefania collecting
leaf samples for sugar isotope.
- Took spectrometer measurement
at Vaira.
- Couldn’t make TDR probe
measurement maybe due to bad connections between cable and TDR machine.
Vaira_Grass
Site
- Fence and gate power: 12
v.
- Panel and Batteries: 12.7 v; 5.8 amps; 3.4 amps.
- Reading from Gillsonic screen
before downloading data. (The value
of H2O and CO2 should be in the range of 0 – 5 v.)
Time
|
|
Path/File name
|
D:\Data\V07_ 235
.flx
D:\Data\VR07 .raw
|
|
mean
|
std
|
|
mean
|
std
|
w
|
0.23
|
0.287
|
Ts
|
41.7
|
1.06
|
u
|
-0.44
|
1.316
|
H2O
|
2.19
|
0.108
|
v
|
0.77
|
1.008
|
CO2
|
1.369
|
0.015
|
|
|
|
Tc
|
3.907
|
0.102
|
- downloading data
- check the fans of air temp.
and relative humidity sensors at Vaira. OK.
- Check MD-9 system connections.
OK.
- Check levels of Radiation
sensors, clear up surfaces. Yes.
- Closed gate and set up fence.
Tonzi_Tower Site
- Fence and gate power: No Fence On v.
- Panel and Batteries: 13.2 v; 0.0 amps; 6.5 amps.
- Reading from Gillsonic screen
before downloading data. (The value
of H2O and CO2 should be in the range of 0 – 5 v.)
Time
|
|
Path/File name
|
D:\Data\T07_ 235 .flx
D:\Data\TW07 .raw
|
|
mean
|
std
|
|
mean
|
std
|
w
|
1.22
|
0.68
|
Ts
|
33.9
|
2.5
|
u
|
1.29
|
0.04
|
H2O
|
3.936
|
0.234
|
v
|
1.0
|
0.92
|
CO2
|
1.413
|
0.078
|
- downloading data
- swaping Li-7500
Analyzer. (Remove SN# 976 ; install SN# 418 )
- check the fans of air temp.
and relative humidity sensors on the tower and the floor.
- Check calibration cylinders;
CO 2 800 psig; flow 20
psi.
N 2 150
psig; flow 20 psi.
Manually calibrate Li-800. Following Ted’s instruction: H:\IoneSavanna_2004\Tower_2004\CO2Profile\LI800_Calibration_Procedure_2Nov04.txt
Is the pump running
How to check the CO2 values
Click “Ports/Flags” button to see which ports or flags is setting
high. Pressure should be less than
ambient value. When Flag 8 is high, it
may indicate that RRR’s battery is low.
- close gate and set up fence. OK.
Toniz_Floor
Site
- Fence and gate power: 12
v.
- Panel and Batteries: 12.9 v; 4.3 amps; 2.1 amps.
- Reading from Gillsonic screen
before downloading data. (The value
of H2O and CO2 should be in the range of 0 – 5 v.)
Time
|
|
Path/File name
|
D:\Data\F07_ 235 .flx
D:\Data\FL07 .raw
|
|
mean
|
std
|
|
mean
|
std
|
w
|
|
|
Ts
|
|
|
u
|
|
|
H2O
|
|
|
v
|
|
|
CO2
|
|
|
- downloading data
- Check MD-9 system connections. OK.
- CR10X7 – CO2
profile
383.8
|
382.0
|
383.5
|
382.7
|
928.7
|
928.8
|
928.8
|
928.6
|
48.5
|
48.35
|
48.3
|
48.4
|
50.7
|
50.7
|
50.8
|
50.8
|
-0.936
|
396.0
|
933.14
|
928.7
|
44.7
|
45.09
|
49.5
|
49.5
|
CR10X8 – wind profile
- Soil CO2 profile: probes are in the lab for calibration.
- Close gate and set up fence. Yes.
|
Field Data
No tank data
No TZ Well data found
No TZ Moisture Point data found
No VR Moisture Point data found
No TZ grass heigth found
No VR grass heigth found
No TZ Tree DBH found
No water potential data found
No TZ Grass Biomass data found
No TZ OakLeaves Biomass data found
No TZ PineNeedles Biomass data found
0 photos found
16 sets found
No data found for TZ_Fenergy.
11 TZ_tmet graphs found
No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found
No data found for TZ_fflux.
8 TZ_fmet graphs found
No data found for TZ_tram.
3 TZ_co2prof graphs found
No data found for TZ_irt.
1 TZ_windprof graphs found
No data found for TZ_tflux.
2 TZ_sm graphs found
Can't check TZ_met
1 TZ_met graphs found
Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data