Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Field Notes

<--2008-03-27 00:00:00 | 2008-04-20 05:30:00-->

Tonzi: 2008-04-04 11:00:00 (DOY 95)
Author: Siyan Ma
Others: Jessica


When: Date: 4/4/2008 , Day: 95 , Watch Time: 11:00 .
Where: Tonzi/Vaira Ranch
Who: Siyan and Jessica
Weather: partially cloudy (4/5)
Phenology: oak leaves out 100%/ green grasses, blooming, blue, purple, and yellow. Talked to Mr. Tonzi. He mentioned that grasses need 3-4 inch. Rainfall during Mar.-Apr. Good to know! The same as we saw from our data!
Summary
  1. Three EC systems worked well.
  2. The forth depth of soil profile system (may be under trees) was -9999.
  3. Collect grass sample and oak leaves and branches for LAI and N, etc.
  4. Read dendrometers
  5. Took measurement of spectrometer (Youngryle)

Vaira_Grass Site
  1. Fence and gate power: >12 v.
  2. Panel and Batteries: 13.7 v; 8.3 amps; 2.6 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\V08_ 95 .flx
D:\Data\VR08 .raw


mean

std


mean

std

w

-0.26

0.491

Ts

20.1

0.938

u

-0.02

1.048

H2O

1.124

0.177

v

4.93

2.144

CO2

1.766

0.033




Tc

1.920

0.093
  1. downloading data YES!
  2. check the fans of air temp. and relative humidity sensors at Vaira. YES!
  3. Check MD-9 system connections YES!
  4. Check levels of Radiation sensors, clear up surfaces. No! because ladder was in Tonzi.
  5. Closed gate and set up fence. YES!

Tonzi_Tower Site

  1. Fence and gate power: 12 v.
  2. Panel and Batteries: 13.3 v; 0.0 amps; 4.8 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\T08_ 95 .flx
D:\Data\TW08 .raw


mean

std


mean

std

w

0.45

0.550

Ts

18.7

0.592

u

0.83

1.103

H2O

1.6

0.052

v

1.8

0.858

CO2

1.8

0.018
  1. downloading data YES!
  2. check the fans of air temp. and relative humidity sensors on the tower and the floor. YES!
  3. Check calibration cylinders;

CO2 1900 psig; flow 15 psi.
N2 2000 psig; flow 19 psi.
  1. close gate and set up fence. YES!

Toniz_Floor Site
  1. Fence and gate power: 12 v.
  2. Panel and Batteries: 13.7 v; 10.9 amps; 1.8 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\F08_95 .flx
D:\Data\FL08 .raw


mean

std


mean

std

w

-0.2

0.208

Ts

17.42

0.63

u

0.19

0.557

H2O

1.229

0.086

v

0.7

1.123

CO2

1.806

0.021
  1. downloading data YES!
  2. Check MD-9 system connections YES!

CR23X3 – floor-Met
CR23X5 – soil CO2 profile
CR23X6 – tower-Met
CR10X2 – floor-Met
CR10X4 – sap-flow
CR10X7 – CO2 profile
CR10X8 – wind profile
  1. Soil CO2 profile

Reading from datalogger

Panel temp

22.93



Battery voltage

13.67



CO2E_1

494

TCE_1

22.3

CO2W_1

744

TCW_1


CO2E_2

744

TCE_2

24.6

CO2W_2

-1875

TCW_2


CO2E_3

1062

TCE_3

18.7

CO2W_3

1454

TCW_3


CO2E_4

2591

TCE_4

15.1

CO2W_4

-9999

TCW_4


Reading from panels of analyzers

depth

Open

order

depth

Tree

order

2cm (1%)

1000

1

2cm (1%)

1440

1

4cm

1510

2

4cm

1990

2

8cm

2120

3

8cm

2930

3

16cm

5240

4

16cm

247%

4
  1. Close gate and set up fence. YES!





Tonzi




Dendrometer







Date

Day

Tag #

Reading (cm)

4/4/2008

95

71

X



72

7.8



77

X



78

X



79

12.1



245

3.5



248

13.1



250

9.5



255

X



‌252‌

X



102


Notes: “X” means not working any more.

tonzi

7931AFE

402165

574B4B

402FF3

574632

7A432E

7A3C6E

7A3B40

7A4AAA

4-Apr-08

95










SM









0-15

22.3

11.5

19.1

11.5

15.0

16.2

14.7

17.3

11.2

15-30

28.9

24.0

25.4

24.9

26.6

14.5

20.6

24.9

12.1

30-45

33.2

36.6

34.2

29.3

41.3

19.3

20.4

27.6

29.9

45-60

38.0

56.9

57.6

48.0

41.1

23.1

33.1

44.0

23.6












A6D882B

A3D04E8

A6D72F5

















0-15

22.6

17.3

7.3







15-30

16.1

16.7

19.7







30-45

27.9

28.2

26.7







45-60

38.0

44.0

46.7

















vaira

57318a

7933dee








0-15

8.8

7.0








15-30

17.6

19.4








30-45

21.8

22.9








45-60

25.6

30.1








Field Data

No tank data

No TZ Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

11 TZ_soilco2 graphs found

Tonzi Soil CO2 Profile: Open (East) CO2

Tonzi Soil CO2 Profile: Tree (West) CO2

Tonzi Soil CO2 Profile: Open (East) Temperatures

Tonzi Soil CO2 Profile: Tree (West) Temperatures

Tonzi Soil CO2 Profile: Upper CO2

Tonzi Soil CO2 Profile: Lower CO2

Tonzi Soil CO2 Profile: Upper Temperatures

Tonzi Soil CO2 Profile: Lower Temperatures

Tonzi Soil CO2 Profile: Power and Temperature

Tree 2 Soil CO2

Tree 2 Soil Temperature

Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

No data found for TZ_fflux.
8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

No data found for TZ_tram.
3 TZ_co2prof graphs found

Tower CO2 Profile Concentrations

Tower CO2 Profile Cell Pressure

CO2 Profile Sensor Temperature

No data found for TZ_irt.
1 TZ_windprof graphs found

Wind Speed Profile

No data found for TZ_tflux.
2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met
1 TZ_met graphs found

Floor and Tower RH

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.