| ALL | | Anemometer || Barometer || Battery Bank || Camera || CO2 Probe || Conductivity Sensor || Data Logger || DO Sensor || Gas Analyzer || Heat Flux Plate || Interface || Multiplexer || Narrow Band || Net Radiometer || PAR Sensor || RH & Temp || Soil Moisture Probe || Solar Controller || Solar Panel || Water Level |

SELECT a.recno, a.eh_date, a.eh_loc1, a.eh_loc2, IF(a.eh_loc2=:loc, a.eh_locref2, a.eh_locref1) AS ref, a.eh_locref2, a.eh_title, a.eh_notes, a.eh_id, b.serialno, b.equip, b.modelno FROM equiphist a INNER JOIN equiplist b ON a.eh_id=b.recno WHERE (a.eh_loc1=:loc1 OR a.eh_loc2=:loc2) ORDER BY b.equip, a.eh_date, field(a.eh_title,'Calibration', 'Removed', 'Installed')

DateSerial No.ModelActionRefNotes
Anemometer
2018-04-17 153803 WM 1590 Installed Anemometer Installed at EP tower as part of initial site set up.
2018-06-28 153803 WM 1590 Moved Anemometer Sensor moved up 26cm to try to address rotation angle issues. The water level was 68cm and the sensor was 540cm above water level.
2020-01-30 153803 WM 1590 Moved Anemometer Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
Barometer
2018-04-17 H0160093 PTB110 Installed Barometer Installed at EP tower as part of initial site set up.
2020-01-30 H0160093 PTB110 Moved Barometer Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
Battery Bank
2018-04-17 BB-EP BB-Fab Installed Battery Bank This is the initial installation of this battery bank. The batteries are from Mayberry and are rather old with dates of July 2010 on them. They were removed from Mayberry when the power failed there but that was probably due to a broken wire rather than weak batteries. The batteries sat idle in the lab for a month or so and didn't seem to lose much charge. Some of them were charged up just before deployment.
2018-07-05 BB-EP BB-Fab Maintenance Battery Bank This battery bank has been loosing power over night. We disconnected all the batteries and tested each one with the load tester. Two tested weak, were removed and brought home. These two may have been the ones lowest on water last time.
2018-07-17 BB-EP BB-Fab Upgrade Battery Bank I turned off all the solar power and removed the four remaining size 27 batteries. These batteries were from Mayberry and were about seven years old. I replaced them with five brand new (July 2018 tags) size 31 Duracell deep cycle batteries. These are part number SLI31MDC and have a capacity of 105Ah. Size 27 are rated at 90Ah, so about the same capacity as six size 27s. After the swap the solar panels were feeding the batteries 20A.
2020-01-20 BB-SW_Temp1 BB-Fab Installed Battery Bank Installed with the initial setup up of the tower. Parts last used at the East Pond site. Five size 31 Duracell deep cycle batteries (July 2018 tags). These are part number SLI31MDC and have a capacity of 105Ah. 12VDC system.
2020-01-30 BB-EP BB-Fab Disposed Battery Bank Removed with the decommissioning of the EP tower, so BB-EP will cease to exist. This equipment will be used at the new SW Temp1 tower and be rechristened BB-SW_Temp1
Camera
2020-01-30 RPI0W-000 RPI0W Moved Camera Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
CO2 Probe
2018-09-18 GP20150109 GP-001 Installed CO2 Probe Installed at East Pond hanging just below the water surface below the data logger box.
2019-09-18 GP20150109 GP-001 Removed CO2 Probe Removed from EP and brought back to the lab for testing b/c it was maxing out.
2019-10-02 GP20150111 GP-001 Installed CO2 Probe Installed at EP.
2020-01-30 GP20150111 GP-001 Moved CO2 Probe Moved from East Pond to temporary tower at Sherman Wetland. No water near the tower to put the probe in, so it's hanging in the air for now.
Conductivity Sensor
2018-04-24 11020258 U24-002-C Installed Conductivity Sensor Installed at East Pond as part of the initial setup.
2019-08-07 11020258 U24-002-C Removed Conductivity Sensor Removed from EP and brought back to the lab for testing. I haven't been able to connect to it through the HOBOware software for a while.
Data Logger
2018-04-17 50889 CR1000 Installed Data Logger Installed at EP tower as part of initial site set up.
2019-01-31 50889 CR1000 Serviced Data Logger Changed Pakbus address from 1 to 89.
2020-01-30 50889 CR1000 Moved Data Logger Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
DO Sensor
2018-04-17 931528 miniDOT-usb Installed DO Sensor Installed at EP tower as part of initial site set up. Hung off of the west end of the tower.
2020-01-30 931528 miniDOT-usb Removed DO Sensor Removed with the decommissioning of the EP tower and bought back to the lab.
Gas Analyzer
2018-04-17 0418 LI-7500A Installed Gas Analyzer CO2/H2O Installed at EP tower as part of initial site set up.
2018-10-10 0418 LI-7500A Calibration Lab Last calibration: 2018-04-13 AGC=93.2 SDM=0 DAC1=0 DAC2=0 Ambient P=99.98kPa, Tair=29.11C, Tdew=15.00C Zero Air at 1500psi, AMP Air 408.97 at 1200 Tdewspan=16.00 CO2 zero 0.9001 -> .8982 Offset: -7.43ppm CO2 span 1.0057 -> .9965 Offset: 4.86ppm H2O zero 0.8426 -> .8454 Offset: 16.8ppm H2O span 0.9892 -> .9813 Offset: 0.16ppm Notes: calibrated by Katrina
2018-04-17 TG1-0211 LI-7700 Installed Gas Analyzer CH4 Installed at EP tower as part of initial site set up.
2018-06-28 0418 LI-7500A Moved Gas Analyzer CO2/H2O Sensor moved up 26cm to try to address rotation angle issues. The water level was 68cm and the sensor was 540cm above water level.
2018-10-10 0418 LI-7500A Calibration Lab Last calibration: 2018-04-13 AGC=93.2 SDM=0 DAC1=0 DAC2=0 Ambient P=99.98kPa, Tair=29.11C, Tdew=15.00C Zero Air at 1500psi, AMP Air 408.97 at 1200 Tdewspan=16.00 CO2 zero 0.9001 -> .8982 Offset: -7.43ppm CO2 span 1.0057 -> .9965 Offset: 4.86ppm H2O zero 0.8426 -> .8454 Offset: 16.8ppm H2O span 0.9892 -> .9813 Offset: 0.16ppm Notes: calibrated by Katrina
2018-06-28 TG1-0211 LI-7700 Moved Gas Analyzer CH4 Sensor moved up 26cm to try to address rotation angle issues. The water level was 68cm and the sensor was 534cm above water level.
2018-10-04 0418 LI-7500A Removed Gas Analyzer CO2/H2O Removed from the East Pond tower for calibration. Replaced by sn 0035.
2018-10-10 0418 LI-7500A Calibration Lab Last calibration: 2018-04-13 AGC=93.2 SDM=0 DAC1=0 DAC2=0 Ambient P=99.98kPa, Tair=29.11C, Tdew=15.00C Zero Air at 1500psi, AMP Air 408.97 at 1200 Tdewspan=16.00 CO2 zero 0.9001 -> .8982 Offset: -7.43ppm CO2 span 1.0057 -> .9965 Offset: 4.86ppm H2O zero 0.8426 -> .8454 Offset: 16.8ppm H2O span 0.9892 -> .9813 Offset: 0.16ppm Notes: calibrated by Katrina
2018-10-04 0035 LI-7500A Installed Gas Analyzer CO2/H2O Installed on the East Pond tower to replace sn 0418 for calibration.
2019-01-28 0035 LI-7500A Calibration Lab Last calibration: 2018-10-02 AGC=99.2 SDM=0 DAC1=0 DAC2=0 Ambient P=100.7kPa, Tair=24.0C, Tdew=10.04C Zero Air at 1200psi, AMP Air 408.97 at 850 Tdewspan=16.00 CO2 zero 0.9375 -> .9375 Offset: .41ppm CO2 span 1.0142 -> 1.0193 Offset: 2.5ppm H2O zero 0.8981 -> .8969 Offset: -7.6ppm H2O span 1.0277 -> 1.0023 Offset: .54ppm Notes: Calibrated by Jiangong. Recorded on the from for sn 0035 but the correct config file (sn 0065) was loaded before the calibration, so the calibration is still good.
2018-10-25 TG1-0211 LI-7700 Calibration Gas Analyzer CH4 Calibration Location: East Pond Last calibration: 2018-04-13 RSSI=74%, Optical RH=10% Ambient P=101.6kPa, Tair=26.4C Zero Air at 1950psi, AMP Air 3.121 at 2100 CH4 Zero Offset: .029ppm CH4 Span Offset: .006ppm Notes: Calm day
2019-01-18 0035 LI-7500A Removed Gas Analyzer CO2/H2O Removed from EP and brought back to the lab for calibration. it was replaced by sn 0073.
2019-01-28 0035 LI-7500A Calibration Lab Last calibration: 2018-10-02 AGC=99.2 SDM=0 DAC1=0 DAC2=0 Ambient P=100.7kPa, Tair=24.0C, Tdew=10.04C Zero Air at 1200psi, AMP Air 408.97 at 850 Tdewspan=16.00 CO2 zero 0.9375 -> .9375 Offset: .41ppm CO2 span 1.0142 -> 1.0193 Offset: 2.5ppm H2O zero 0.8981 -> .8969 Offset: -7.6ppm H2O span 1.0277 -> 1.0023 Offset: .54ppm Notes: Calibrated by Jiangong. Recorded on the from for sn 0035 but the correct config file (sn 0065) was loaded before the calibration, so the calibration is still good.
2019-01-18 0073 LI-7500A Installed Gas Analyzer CO2/H2O Installed at EP to replace sn 0035, which was brought back to the lab for calibration.
2019-04-23 0073 LI-7500A Calibration Lab Last calibration: 2019-01-07 AGC=98.6 SDM= DAC1= DAC2= Ambient P=100.4kPa, Tair=26.0C, Tdew=11.8C Zero Air at 1100psi, AMP Air 408.97 at 700 Tdewspan=16.00 CO2 zero 0.956 -> .9563 Offset: .91ppm CO2 span 1.0081 -> 1.0094 Offset: -0.78ppm H2O zero 0.7316 -> .7336 Offset: 12.1ppm H2O span 1.0023 -> 1.0153 Offset: -.26ppm Notes:
2019-04-11 TG1-0211 LI-7700 Calibration Gas Analyzer CH4 Calibration Location: East Pond Last calibration: 2018-10-26 RSSI=70%, Optical RH=14% Ambient P=101.9kPa, Tair=17.1C Zero Air M4002 at 1600psi, AMP CA03923 3.121 at 1800 CH4 Zero Offset: 0.014ppm CH4 Span Offset: 0.003ppm Notes: Windy day
2019-04-18 0073 LI-7500A Removed Gas Analyzer CO2/H2O Removed from EP and brought back to the lab for calibration. It was replaced by sn 0065.
2019-04-23 0073 LI-7500A Calibration Lab Last calibration: 2019-01-07 AGC=98.6 SDM= DAC1= DAC2= Ambient P=100.4kPa, Tair=26.0C, Tdew=11.8C Zero Air at 1100psi, AMP Air 408.97 at 700 Tdewspan=16.00 CO2 zero 0.956 -> .9563 Offset: .91ppm CO2 span 1.0081 -> 1.0094 Offset: -0.78ppm H2O zero 0.7316 -> .7336 Offset: 12.1ppm H2O span 1.0023 -> 1.0153 Offset: -.26ppm Notes:
2019-04-18 0065 LI-7500A Installed Gas Analyzer CO2/H2O Installed at EP to replace sn 0073, which was brought back to the lab for calibration.
2019-08-21 0065 LI-7500A Calibration Lab Last calibration: 2019-04-15 AGC=100 SDM=0 DAC1=- DAC2=- Ambient P=100.3kPa, Tair=27.6C, Tdew=15.0C Zero Air at 1000psi, AMP CO2 408.97 at 800 Tdewspan=20.0 CO2 zero 0.8911 -> 0.8916 Offset: 2.25ppm CO2 span 1.0171 -> 1.0191 Offset: -0.97ppm H2O zero 0.726 -> 0.7278 Offset: 14.2ppm H2O span 1.0118 -> 1.0165 Offset: -0.1ppm Notes: Water zero offset a little large - maybe still acclimating from factory service and new internal chemicals. Signal Strength reset from 101.1 to 100.0
2019-08-07 0065 LI-7500A Removed Gas Analyzer CO2/H2O Removed from EP and brought back to the lab for calibration. It was replaced by sn 0035.
2019-08-21 0065 LI-7500A Calibration Lab Last calibration: 2019-04-15 AGC=100 SDM=0 DAC1=- DAC2=- Ambient P=100.3kPa, Tair=27.6C, Tdew=15.0C Zero Air at 1000psi, AMP CO2 408.97 at 800 Tdewspan=20.0 CO2 zero 0.8911 -> 0.8916 Offset: 2.25ppm CO2 span 1.0171 -> 1.0191 Offset: -0.97ppm H2O zero 0.726 -> 0.7278 Offset: 14.2ppm H2O span 1.0118 -> 1.0165 Offset: -0.1ppm Notes: Water zero offset a little large - maybe still acclimating from factory service and new internal chemicals. Signal Strength reset from 101.1 to 100.0
2019-08-07 0035 LI-7500A Installed Gas Analyzer CO2/H2O Installed at EP to replace sn 0065, which was brought back to the lab for calibration.
2019-11-18 0035 LI-7500A Calibration Lab Last calibration: 2019-08-01 AGC=100.1 SDM=0 DAC1=- DAC2=- Ambient P=100.4kPa, Tair=26.4C, Tdew=10.0C Zero Air at 950psi, AMP CA04396 408.97 at 600 Tdewspan=20.0 CO2 zero 0.9374 -> 0.9374 Offset: 0.0ppm CO2 span 1.0207 -> 1.0170 Offset: 1.93ppm H2O zero 0.8984 -> 0.8980 Offset: -2.6ppm H2O span 1.0323 -> 1.0314 Offset: 0.03ppm Notes: by Joe
2019-09-04 TG1-0211 LI-7700 Upgrade Gas Analyzer CH4 We updated the 7700 firmware from v1.0.23 to v1.0.27. First try failed part way through, second try was successful.
2019-10-22 TG1-0211 LI-7700 Calibration Gas Analyzer CH4 Calibration Location: East Pond Last calibration: 2019-04-11 RSSI=72%, Optical RH=19% Ambient P=101.9kPa, Tair=26.1C Zero Air at 1300psi, AMP CA03923 3.121 at 1200 CH4 Zero Offset: 0.003ppm CH4 Span Offset: -0.001ppm Notes:
2019-11-14 0035 LI-7500A Removed Gas Analyzer CO2/H2O Removed from East Pond and brought back to the lab for calibration. Replaced by sn 0041.
2019-11-18 0035 LI-7500A Calibration Lab Last calibration: 2019-08-01 AGC=100.1 SDM=0 DAC1=- DAC2=- Ambient P=100.4kPa, Tair=26.4C, Tdew=10.0C Zero Air at 950psi, AMP CA04396 408.97 at 600 Tdewspan=20.0 CO2 zero 0.9374 -> 0.9374 Offset: 0.0ppm CO2 span 1.0207 -> 1.0170 Offset: 1.93ppm H2O zero 0.8984 -> 0.8980 Offset: -2.6ppm H2O span 1.0323 -> 1.0314 Offset: 0.03ppm Notes: by Joe
2019-11-14 0041 LI-7500A Installed Gas Analyzer CO2/H2O Installed at East Pond to replace sn 0035 for calibration.
2020-05-13 0041 LI-7500A Calibration Lab Last calibration: 2019-11-12 AGC=100.9 SDM= DAC1= DAC2= Ambient P=100.7kPa, Tair=21.6C, Tdew=9.7C Zero Air at 725psi, AMP CA4396 408.97 at 550 Tdewspan=16.00 CO2 zero 0.9968 -> .9966 Offset: -0.6ppm CO2 span 1.0146 -> 1.0180 Offset: -2.16ppm H2O zero 0.8218 -> .8210 Offset: -4.2ppm H2O span 1.0267 -> 1.0256 Offset: 0.02ppm Notes:
2020-01-30 TG1-0211 LI-7700 Moved Gas Analyzer CH4 Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
2020-01-30 0041 LI-7500A Moved Gas Analyzer CO2/H2O Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
2020-05-13 0041 LI-7500A Calibration Lab Last calibration: 2019-11-12 AGC=100.9 SDM= DAC1= DAC2= Ambient P=100.7kPa, Tair=21.6C, Tdew=9.7C Zero Air at 725psi, AMP CA4396 408.97 at 550 Tdewspan=16.00 CO2 zero 0.9968 -> .9966 Offset: -0.6ppm CO2 span 1.0146 -> 1.0180 Offset: -2.16ppm H2O zero 0.8218 -> .8210 Offset: -4.2ppm H2O span 1.0267 -> 1.0256 Offset: 0.02ppm Notes:
Heat Flux Plate
2018-04-17 00244 HFP01SC Installed Heat Flux Plate A Installed at EP tower as part of initial site set up in profile A (north) and mux channel 10
2018-04-17 00245 HFP01SC Installed Heat Flux Plate B Installed at EP tower as part of initial site set up in profile B (west) and mux channel 10
2018-04-17 10809 HFP01 Installed Heat Flux Plate C Installed at EP tower as part of initial site set up in profile C (South) and mux channel 10
2020-01-30 00244 HFP01SC Disposed Heat Flux Plate A In the process of decommissioning the EP tower this heat flux plate was lost when its cable broke off at the plate.
2020-01-30 00245 HFP01SC Moved Heat Flux Plate B Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
2020-01-30 10809 HFP01 Moved Heat Flux Plate C Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
Interface
2018-04-17 AIU-0666 LI-7550 Installed Gas Analyzer CO2/H2O Installed at EP tower as part of initial site set up.
2018-04-19 AIU-0666 LI-7550 Removed Gas Analyzer CO2/H2O Removed from East Pond because it is supposed to be use in the lab for calibrations.
2018-04-19 AIU-0650 LI-7550 Installed Gas Analyzer CO2/H2O Installed on the East Pond tower to replace sn AIU-0666 that is supposed to be used in the lab for calibrations.
2020-01-30 AIU-0650 LI-7550 Moved Gas Analyzer CO2/H2O Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
Multiplexer
2018-04-17 1429 AM16/32A Installed Multiplexer Met Installed at EP tower as part of initial site set up.
2018-04-17 2856 AM25T Installed Multiplexer Thermocouple Installed at EP tower as part of initial site set up.
2018-05-03 1429 AM16/32A Notes Multiplexer Met This mux also has spikes/drops in some channels, so starting to move sensors around to avoid spikes.
2018-06-13 1429 AM16/32A Removed Multiplexer Met Removed from East Pond due to spikes on worn out channels
2018-06-13 1164 AM16/32A Installed Multiplexer Met Installed at East Pond to replace one with worn out channels. This one came off the decommissioned TA site.
2020-01-30 1164 AM16/32A Moved Multiplexer Met Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
2020-01-30 2856 AM25T Moved Multiplexer Thermocouple Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
Narrow Band
2018-05-16 2046503368 SRS-Ni NDVI Installed Narrow Band NDVI Incoming Installed on the East Pond tower in the incoming postion
2018-05-16 2046503402 SRS-Ni NDVI Installed Narrow Band NDVI Reflected Installed on the East Pond tower in the outgoing postion
2020-01-30 2046503368 SRS-Ni NDVI Moved Narrow Band NDVI Incoming Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
2020-01-30 2046503402 SRS-Ni NDVI Moved Narrow Band NDVI Reflected Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
Net Radiometer
2018-04-17 990181 CNR1 Installed Net Radiometer 4-way Installed at EP tower as part of initial site set up.
2020-01-30 990181 CNR1 Moved Net Radiometer 4-way Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
PAR Sensor
2018-04-17 050597 PAR-LITE Installed PAR Sensor Incoming Installed at EP tower as part of initial site set up. This sensor is in the upward facing position collecting incoming PAR
2018-04-17 050596 PAR-LITE Installed PAR Sensor Reflected Installed at EP tower as part of initial site set up. This sensor is in the downward facing position collecting reflected PAR
2020-01-30 050596 PAR-LITE Moved PAR Sensor Reflected Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
2020-01-30 050597 PAR-LITE Moved PAR Sensor Incoming Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
RH & Temp
2018-04-17 G4540021 HMP60 Installed RH & Temp Installed at EP tower as part of initial site set up. We dropped the sensor in the water, but the sensor looks dry and the numbers seem fine.
2020-01-30 G4540021 HMP60 Moved RH & Temp Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
Soil Moisture Probe
2018-04-17 17131 CS655 Installed Soil Moisture Probe B Installed at EP tower as part of initial site set up near profile B (South).
2018-04-17 17130 CS655 Installed Soil Moisture Probe C Installed at EP tower as part of initial site set up near profile C (South).
2020-01-30 17130 CS655 Removed Soil Moisture Probe C Removed with the decommissioning of the EP tower and bought back to the lab.
2020-01-30 17131 CS655 Removed Soil Moisture Probe B Removed with the decommissioning of the EP tower and bought back to the lab.
Solar Controller
2018-04-17 12501588 PS-15M Installed Solar Controller Secondary Installed at EP tower as part of initial site set up about 12m NNW of the tower
2018-04-17 12501584 PS-15M Installed Solar Controller Installed at EP tower as part of initial site set up about 12m NNW of the tower
2018-05-10 12501584 PS-15M Removed Solar Controller Removed from East Pond. Replaced by 30A controller.
2018-05-10 12501588 PS-15M Removed Solar Controller Secondary Removed from East Pond. Replaced by 30A controller.
2018-05-10 11400080 PS-30M Removed Solar Controller Removed from Twitchell Alfalfa to swap out a 15A version to be installed here.
2018-05-10 11400080 PS-30M Installed Solar Controller Installed at East Pond in a new smaller box on the solar system to replace the two 15A charger controllers that were running in parallel.
2018-05-10 12501584 PS-15M Installed Solar Controller Removed from East Pond in favor of a 30A version and installed at Twitchell Alfalfa
2020-01-30 11400080 PS-30M Moved Solar Controller Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
Solar Panel
2018-04-17 11ZV0M0836 KD140SX-UFBS Installed Solar Panel B Installed at EP tower as part of initial site set up about 12m NNW of the tower
2018-04-17 11ZV0M0855 KD140SX-UFBS Installed Solar Panel C Installed at EP tower as part of initial site set up about 12m NNW of the tower
2018-04-17 11ZV0M0829 KD140SX-UFBS Installed Solar Panel A Installed at EP tower as part of initial site set up about 12m NNW of the tower
2020-01-30 11ZV0M0829 KD140SX-UFBS Moved Solar Panel A Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
2020-01-30 11ZV0M0836 KD140SX-UFBS Moved Solar Panel B Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
2020-01-30 11ZV0M0855 KD140SX-UFBS Moved Solar Panel C Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.
Water Level
2018-04-17 20010770 CS450 Installed Water Level Installed at EP tower as part of initial site set up.
2020-01-30 20010770 CS450 Moved Water Level Removed with the decommissioning of the EP tower and installed at the new SW Temporary site 1250m upwind of the Permanent Tower.