Equipment and Calibration History
History for MorningStar PS-30M 02431248
Rec No. | Date | Loc From | Title | Loc To | Notes |
---|---|---|---|---|---|
3397 | 2017-06-02 | Lab none | Tested | Lab none | I tested this controller in the lab and talked with a Morningstar technician. The consensus is that something failed on the board that disabled the load. It might be fine for charging batteries though. |
2220 | 2016-03-08 | Tonzi-Tower | Removed | Lab none | This charge controller was at the Tonzi Tower. It could not read the battery bank voltage and had shutdown the load with a Low Voltage Disconnect message. I removed it and replaced it with the controller from the Tram system sn 0135002X |