Equipment and Calibration
Equipment history at Tonzi| ALL | | Anemometer || Barometer || Battery Bank || Camera || CO2 Probe || Data Logger || Forced Diffusion || Gas Analyzer || Heat Flux Plate || Infrared Temperature || Interface || LED sensor || Moisture Point || Multiplexer || Narrow Band || Net Radiometer || PAR Sensor || Precipitation || Radio || RH & Temp || Soil Moisture Probe || Soil Water Potential || Solar Controller || Solar Panel || Water Level || Weather Station |
SELECT a.recno, a.eh_date, a.eh_loc1, a.eh_loc2, IF(a.eh_loc2=:loc, a.eh_locref2, a.eh_locref1) AS ref, a.eh_locref2, a.eh_title, a.eh_notes, a.eh_id, b.serialno, b.equip, b.modelno FROM equiphist a INNER JOIN equiplist b ON a.eh_id=b.recno WHERE (a.eh_loc1=:loc1 OR a.eh_loc2=:loc2) AND b.equip=:eq ORDER BY b.serialno, a.eh_date
Date | Serial No. | Model | Action | Ref | Notes |
---|---|---|---|---|---|
Solar Controller | |||||
2020-07-07 | 0127000A | PS-30M | Removed | none | Removed from the Floor solar system. I needed a 30A model for the tower going to Steve and Sabina. Since updating this system 24V the amp load has decreased below 15A. Replaced by sn 12501584. |
2016-03-08 | 0135002X | PS-30M | Moved | I moved this charge controller from the Tram solar system to the main Tower power system. The existing charge controller at the tower sn 02431248 stopped reading the battery voltage. | |
2017-09-28 | 0135002X | PS-30M | Removed | Removed from the Tonzi Tower solar system were it was serving as a Low Voltage Disconnect. The system was upgraded with a new MPPT charge controller. | |
2020-07-07 | 12501584 | PS-15M | Installed | none | Installed at Tonzi to replace sn 0127000A for use elsewhere. Since updating the solar power to 24V the 30A model is not required. |
2020-07-07 | 12501588 | PS-15M | Installed | none | Installed in the Soil CO2 box under the tree at Tonzi. I swapped out an old 1st gen 30A model sn 186580399. |
2023-03-01 | 12501588 | PS-15M | Removed | Solar Controller Soil CO2 | This solar controller has not been showing solar amps and doesn't seem to charge batteries. I brought it in for testing |
2018-04-25 | 186580399 | PS-30M | Location | This charge controller is running the soil CO2 solar system. The system is 24V. It has been here for at least the last 10 years. | |
2020-07-07 | 186580399 | PS-30M | Removed | Removed from the Soil CO2 box under the tree. This is an old 1st generation model. I put in a newer 15A 2nd model sn 12501588 since the power requirements here are small. | |
2023-03-01 | 21501223 | SS-6L-12V | Installed | Solar Controller Soil CO2 | Installed at the soil CO2 battery bank to replace sn 12501588 that doesn't seem to be charging batteries. |
2018-05-11 | 3317052234210 | CMTD-As4s0 | Installed | none | Installed at the Road Well to power Global Water sensor. |
2017-09-28 | KB04594 | MNKID-B | Installed | Installed on the Tonzi Tower to upgrade the solar system. The solar system is now three parallel strings of four panels in series approximately 12A at 80VDC. The battery bank was rewired to be a 24V system. | |
2017-09-28 | SCC-001 | C60 | Removed | Removed from the Tonzi Tower solar system. The system was upgraded with a new MPPT charge controller. |