ID | SMAP Loc | Model | Serial No. | Last Entry | Current Location | Project | Description |
---|---|---|---|---|---|---|---|
1082 | Soil Moisture Annex | Campbell CS655 | 67373 | 2025-03-26 | Rush Ranch | CSUEB | Patty purchased for the Rush Ranch tower. 5m (17ft) cable, pigtail ends. |
1081 | Soil Moisture Annex B | Campbell CS655 | 67372 | 2025-03-26 | Rush Ranch | CSUEB | Patty purchased for the Rush Ranch tower. 5m (17ft) cable, pigtail ends. |
1072 | Pyrgeometer Annex Outgoing | Apogee SL-610-SS | 1408 | 2025-03-26 | Rush Ranch | CSUEB | Ordered by Patty for reflected LW on the annex tower at RR out in the marsh. |
1071 | Solar Panel | Kyosera KD140SX-UPU | 122HLM1112 | 2024-12-20 | Rush Ranch | USGS-RR | East most of three at the Rush Ranch site 140W, 17.7V, 7.91A |
1070 | Solar Panel | Kyosera KD140SX-UPU | 122HLM1126 | 2024-12-20 | Rush Ranch | USGS-RR | Middle of three at the Rush Ranch site 140W, 17.7V, 7.91A |
1069 | Solar Panel | Kyosera KD140SX-UPU | 122HLM0641 | 2024-12-20 | Rush Ranch | USGS-RR | West most of three at the Rush Ranch site 140W, 17.7V, 7.91A |
1064 | Battery Bank | Fabricated BB-Fab | 2024-11-15 | Rush Ranch | USGS-RR | Solar battery bank as set up by Frank Anderson at the start up of the Rush Ranch site | |
1063 | PAR Sensor Annex Outgoing | Licor Quantum | Q40957 | 2025-03-26 | Rush Ranch | USGS-RR | Short cable, Brought to UCB by Kat Cone for the handoff of Rush Ranch. This sensor comes with its very own coax resistor adapter with a 785 Ohm value to result in a multiplier of 200(umol/m2/s)/mV |
1060 | Soil Moisture | Campbell Sci CS616 | 13932-3 | 2024-10-24 | Rush Ranch | USGS-RR | In ground at Tower, Acquired with the handoff of Rush Ranch |
1059 | Heat Flux Plate | REBS HFT3 | H993xx2 | 2024-10-24 | Rush Ranch | USGS-RR | cal 37.4 (W/m2)/mV, sn unknown, In ground at Tower, Acquired with the handoff of Rush Ranch |
1058 | Heat Flux Plate | REBS HFT3 | H993xx1 | 2024-10-24 | Rush Ranch | USGS-RR | cal 34.3 (W/m2)/mV, sn unknown, In ground at Tower, Acquired with the handoff of Rush Ranch |
1055 | Soil Moisture | Campbell Sci CS616 | 13932-5 | 2024-12-18 | Rush Ranch | USGS-RR | Broken - no tines, Acquired with the handoff of Rush Ranch |
1054 | Net Radiometer 4-way | Kipp & Zonen CNR1 | 90268 | 2024-12-18 | Rush Ranch | USGS-RR | Acquired with the handoff of Rush Ranch. From the old met program, the coefficient for all 4 sensors is 8.53 uV/W/m2. |
1051 | Water Level Annex | Global Water WL-400-003 | 1202000485 | 2025-05-04 | Rush Ranch | USGS-RR | Acquired with the handoff of Rush Ranch |
1046 | Camera | StarDot CAM-SEC5IR | 0030F4D0A725 | 2024-11-14 | Rush Ranch | USGS-RR | Acquired with the handoff of Rush Ranch |
1040 | PAR Sensor Outgoing | Licor Quantum | Q40954 | 2024-12-18 | Rush Ranch | USGS-RR | Acquired with the handoff of Rush Ranch. This sensor comes with its very own coax resistor adapter with a 821 Ohm value to result in a multiplier of 200(umol/m2/s)/mV |
1039 | PAR Sensor Incoming | Licor Quantum | Q40955 | 2024-12-18 | Rush Ranch | USGS-RR | Acquired with the handoff of Rush Ranch. This sensor comes with its very own coax resistor adapter with a 794 Ohm value to result in a multiplier of 200(umol/m2/s)/mV |
1021 | Data Logger | Campbell CR1000 | 42656 | 2024-12-18 | Rush Ranch | USGS-RR | Wiring Panel 36048, Brought to UCB by Kat Cone for the handoff of Rush Ranch |
1019 | Pyranometer Diffuse | Delta-T SPN1 | SPN1-A333 | 2024-12-18 | Rush Ranch | USGS-RR | Diffuse Short Wave, Brought to UCB by Kat Cone for the handoff of Rush Ranch |
1014 | RH & Temp | Vaisala HMP35C | 375061 | 2024-12-18 | Rush Ranch | USGS-RR | Campbell or USGS assigned serial number, Brought to UCB by Kat Cone for the handoff of Rush Ranch |
1010 | RH & Temp Annex | Vaisala HMP45A | F1830005 | 2025-03-26 | Rush Ranch | USGS-RR | Brought to UCB by Kat Cone for the handoff of Rush Ranch. The serial number on the cable says sn E5330145, but we will use the serial number on the sensor body, sn F1830005. |
1009 | Interface | Campbell NL115 | 12397 | 2024-11-14 | Rush Ranch | USGS-RR | Came attached to CR1000 sn 45312, Brought to UCB by Kat Cone for the handoff of Rush Ranch |
1008 | Data Logger Annex | Campbell CR1000 | 45312 | 2025-03-26 | Rush Ranch | USGS-RR | Wiring Panel 38615. Was in a box collecting high frequency flux data and phenocam images., Brought to UCB by Kat Cone for the handoff of Rush Ranch |
1006 | Precipitation | Texas Electronics TR-525M | 23374-1298 | 2024-12-18 | Rush Ranch | Goldstein Lab | Part of the equipment rescued from a clean out of Allen Goldstein's storage space. |
996 | Barometer | Vaisala PTB101B | W1020003 | 2025-01-30 | Rush Ranch | Goldstein Lab | Part of the equipment rescued from a clean out of Allen Goldstein's storage space |
901 | Heat Flux Plate Annex C | TE Technology HP-127-1.0-1.3-71P | PC4 | 2025-03-26 | Rush Ranch | CDFW | Potted (water proof) peltier chip, aka sn P09 |
900 | Heaf Flux Plate Annex B | TE Technology HP-127-1.0-1.3-71P | PC3 | 2025-03-26 | Rush Ranch | CDFW | Potted (water proof) peltier chip, aka sn P08 |
878 | Soil Moisture Annex C | Campbell Sci. CS616 | ag-tdr01 | 2025-03-26 | Rush Ranch | Borrowed | Borrowed from Allen Goldstein's lab. 100ft of cable |
877 | Heaf Flux Plate Annex A | Hukseflux HFP01 | 003047 | 2025-03-26 | Rush Ranch | Borrowed | Borrowed from Allen Goldstein's lab. Calibration factor 60.5 uV/(W/m2), 50ft cable - probably sn 3047 actually |
876 | Heat Flux Plate A | Hukseflux HFP01 | 003073 | 2024-12-18 | Rush Ranch | Borrowed | Borrowed from Allen Goldstein's lab. Calibration factor 63.3 uV/(W/m2), 50ft cable |
605 | Radio | Campbell Sci. RF400 | 21519 | 2025-03-26 | Rush Ranch | DOE-TCP | |
604 | Radio Annex | Campbell Sci. RF400 | 21520 | 2025-03-26 | Rush Ranch | DOE-TCP | |
451 | Interface | Licor LI-7550 | AIU-1570 | 2024-10-24 | Rush Ranch | CDFW | GHG-1 package comprised of: sn TG1-0424, sn 75H-2669, sn AIU-1570 |
357 | Gas Analyzer CH4 | Licor LI-7700 | TG1-0203 | 2024-10-24 | Rush Ranch | USGS-RR | Brought to UCB by Kat Cone for the handoff of Rush Ranch. Previously this sensor was borrowed from Frank Anderson along with a was box and required cables. It will be deployed on the Corn / Construction tower for a aircraft flight in mid September and maybe returned soon afterwards. |
335 | Anemometer | Gill WM 1590 | 120908 | 2024-10-24 | Rush Ranch | DWR-Wetland | 4x14bit analog out, 20Hz, Firmware version 2329-116-01 |
275 | Multiplexer Annex | Campbell Sci. AM25T | 6768 | 2025-03-26 | Rush Ranch | DWR-Wetland | |
125 | Pyranometer Annex Outgoing | Kipp & Zonen CM11 | 996985 | 2025-03-26 | Rush Ranch | Startup | Inital factory calibration 4.90 uV/(W/m2) |
45 | Multiplexer | Campbell Sci. AM25T | 4852 | 2024-12-18 | Rush Ranch | NSF-Methane | |
16 | Gas Analyzer CO2/H2O | Licor LI-7500A | 0041 | 2025-02-18 | Rush Ranch | NULL | Originally a LI-7500 converted to a LI-7500A on 2017-05-03 |