Field Notes
<--2003-05-30 04:24:00 | 2003-06-06 00:00:00-->Other sites visited today: Tonzi/Vaira
Phenocam link: Searching...
Tonzi/Vaira: 2003-05-30 13:30:00 (DOY 150)
Author: Ted Hehn
Others:
Summary: Emergency trip to fix Floor system - dead sonic and IRGA taken to Vaira
When: Wed., 30May03, JD-150 Where: Tonzi/Vaira Ranches Who: Ted Hehn Weather Clear, warm and calm Trip Purpose: Emergency trip to reintegrate floor flux platform. Tonzi Ranch: 13:30 Arrive. Floor system not operational. Unplug sonic power lead on xlator box and repower up. OK system starts up but then fails almost immediately. Remove sonic sn 000019 and xlator box and install sonic sn 000024 and new xlator box. Power down system with regulator switch. Ok powers up and begins taking data. Install new licor 7500 power lead. OK- all appears well 18:00 Tower system failure: PC on gillsonic chart on PC monitor but no data being taken. Unplug PC power lead and reboot PC. OK system boots and begins taking data. Leave site Vaira Ranch: All appears well at the Vaira site. |