Field Notes
<--2017-07-17 09:30:00 | 2017-07-19 11:00:00-->Other sites visited today: East End
Phenocam link: Searching...
East End: 2017-07-17 14:00:00 (DOY 198)
Author: Ada Chang
Others: Elke Eichelmann
Summary: Conductivity NaN at Permanent Tower. MET battery empty at Open Water T1. Closed Canopy T2 was fine.
Permanent Tower Arrived at 14:00. Weather was warm and clear. MET data looked good. Conductivity was NaN, which might mean that it was exposed to air. The data started on 2017-07-09. Tried COLLECT ALL. Fixed to data on 2017-07-13 at 11:00. Swapped the flash card and cleaned the radiation sensor. LI7500 readings: CO2 399.30 H2O 502.6 T 32.98 P 100.88 SS 92.5 -> 93.6 LI7700 readings: CH4 2.08 RSSI 36.5 -> 81 Open Water T1 Arrived at 14:45. MET battery was empty, and we replaced it with one from the LI6400 setup. Data was recorded until 2017-07-10. There was a spider web across the 7700 path which may account for data descrepancies. LI7500 readings: CO2 388.04 H2O 480.8 T 33.26 P 101.25 SS 107.06 -> 108.7 LI7700 readings: CH4 2.02 RSSI 20 -> 63 Closed Canopy T2 Arrived at 15:20. Collected USB data. MET data looked good. LI7500 readings: CO2 387.8 H2O 505.8 T 35.35 P 100.42 SS 89.9 -> 92.6 LI7700 readings: CH4 2.02 RSSI 47 -> 68 |
0 photos found
11 sets found
14 EE_met graphs found
Can't check EE_mixed
1 EE_mixed graphs found
8 EE_flux graphs found
Can't check MBWPEESWGT_mixed
1 EE_cam graphs found
Can't check MBEEWPSWEPGT_cam
Can't check SIMBTWEE_met
Can't check EE_Temp
5 EE_Temp graphs found
Can't check EE_minidot
1 EE_minidot graphs found
Can't check MBSWEEWPBCBA
1 EE_processed graphs found