Field Notes

<--2008-10-23 11:00:00 | 2008-11-25 08:30:00-->
Phenocam link: Searching...

Sherman Island: 2008-11-12 03:10:00 (DOY 317)
Author: Dennis Baldocchi
Others:

Summary: Sample LAI and plant height; sample water table ports; took spectrometer reflectance readings; took TDR soil moisture readings; downloaded Sherman Island data.

When: Date: nov 12 , Day: , Watch Time: 310 pm .

Where: Sherman Island Methane Study

Who: ddb

Weather; mild temp, light winds, clear

Phenology: the pepperweed has died, but green grass has come up since the big rains a couple weeks back

The nearest ditch was full of water up to the tower level

The PC and CR clocks were way off, 2hours and 10 minutes fast. I reset the clocks with the internet and renamed ‘future’ raw files, for 1530, 1600 1630 and 1700 so they wont get written over and lost or crash the system. For example the 1700 file will need to be renames something like 1500, etc and work back with the files until we find when solar noon is creeping 1 and 2 hours

Tasks

  1. check and download data at Sherman Island
  2. Take TDR soil moisture readings
  3. take spectrometer reflectance reading
  4. Sample additional water Table ports
  5. Sample LAI and plant height

Sherman Island Pasture Site

  1. Fence and gate power: v.
  2. Datalogger Solar Panel and Batteries: v;
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time

Path/File name

D:\Data\SI07_ .flx

D:\Data\SI07 .raw

mean

std

mean

std

w

Ts

u

H2O

v

CO2

CH4

1.834

  1. Methane Sensor
    1. Cell Pressure (near 159 Torr?):___117__
    2. Cell Temperature: _____25
    3. Time Constant:_____16.7
    4. Double Check

i. Sample rate: 10Hz?:_x___

ii. Methane ppm Hi flow:x

iii. Methane ppm, low flow (remember to put back in high flow:

iv. Pump status??:__x__

v. Filter Status:____cleaned 40 umcon filter__

vi. Check Water in tube:

vii. Little water in tube and drained it

e. Cleaning filter improved pressure to 123 torr. We need to change and clean 2 micron filter next time and recalibrate. The methane signal seems a bit low due to the lower pressure….

  1. downloading data
  2. If Swapping Li-7500 Analyzer. (Remove SN# ; install SN# )
  3. Check the fans of air temp. and relative humidity sensors
  4. Check MD-9 system connections
  5. Check CR23X with two multiplexers and sensor values
  6. Check levels of Radiation sensors, clear up surfaces.

Closed gate and set up fence.

2 photos found

Cows and birds
SI_webcam_2008317_1545.jpg ( 2008-11-12 17:45:02 ) Full size: 640x480
Cows and birds

Morning moon
SI_webcam_2008318_0645.jpg ( 2008-11-13 08:45:02 ) Full size: 640x480
Morning moon

Graphs display:
7 sets found

No data found for SI_mp.
10 SI_met graphs found

Explore the graph:Solar Radiation in a new window

Explore the graph:Energy in a new window

Explore the graph:Soil Temperatures Set 1 in a new window

Explore the graph:Soil Temperatures Set 2 in a new window

Explore the graph:Soil Temperatures Set 3 in a new window

Explore the graph:Soil Temperature at -16cm in a new window

Explore the graph:Solar Radiation from CNR1 in a new window

Explore the graph:Sherman Island Rain in a new window

Explore the graph:Sherman Well Level in a new window

Explore the graph:Box Temperatures in a new window

Can't check SI_mixed
2 SI_mixed graphs found

Explore the graph:Theta Probes in a new window

Explore the graph:Sherman Island Air Temperatures in a new window

4 SI_flx graphs found

Explore the graph:Sonic Wind in a new window

Explore the graph:CH4 Concentrations in a new window

Explore the graph:Sample Counts in a new window

Explore the graph:LI7500 CO2 and H2O in a new window

No data found for SI_soilco2.
Can't check TWSI_mixed
Can't check SIMBTWEE_met