Equipment and Calibration History
History for MorningStar PS-30M 0135002X
Rec No. | Date | Loc From | Title | Loc To | Notes |
---|---|---|---|---|---|
4551 | 2018-01-11 | Lab none | Installed | Mayberry none | Installed at MB to replace sn 04350908, which was full of ants. |
3094 | 2017-09-28 | Tonzi | Removed | Lab none | Removed from the Tonzi Tower solar system were it was serving as a Low Voltage Disconnect. The system was upgraded with a new MPPT charge controller. |
2219 | 2016-03-08 | Tonzi | Moved | Tonzi-Tower | I moved this charge controller from the Tram solar system to the main Tower power system. The existing charge controller at the tower sn 02431248 stopped reading the battery voltage. |