Equipment and Calibration
Equipment history at Mayberry| ALL | | Anemometer || Barometer || Battery Bank || Camera || CH4 Probe || CO2 Probe || CO2 Transmitter || Conductivity Sensor || Data Logger || DO Sensor || Fluorometer || Forced Diffusion || Gas Analyzer || Heat Flux Plate || Infrared Temperature || Interface || LED sensor || Multiplexer || Narrow Band || Net Radiometer || PAR Sensor || Precipitation || Range Finder || RH & Temp || Soil Moisture Probe || Solar Controller || Solar Panel || Water Level |
SELECT a.recno, a.eh_date, a.eh_loc1, a.eh_loc2, IF(a.eh_loc2=:loc, a.eh_locref2, a.eh_locref1) AS ref, a.eh_locref2, a.eh_title, a.eh_notes, a.eh_id, b.serialno, b.equip, b.modelno FROM equiphist a INNER JOIN equiplist b ON a.eh_id=b.recno WHERE (a.eh_loc1=:loc1 OR a.eh_loc2=:loc2) AND b.equip=:eq ORDER BY b.serialno, a.eh_date
Date | Serial No. | Model | Action | Ref | Notes |
---|---|---|---|---|---|
Water Level | |||||
2012-10-25 | 20010026 | CS450 | Moved | Water Level | Removed from the Twitchell tower since the well was dry and moved to the Mayberry Tule tower to replace the water pressure sensor that failed there. |
2012-11-29 | 20010026 | CS450 | Removed | Water Level | This sensor was removed from the Tule tower due to bad readings. Replaced by brand new CS451 sn20010046 sensor. |
2024-04-04 | 20010026 | CS450 | Installed | Water Level | Installed at MB off of the northeast corner of the scaffolding. Water level data from the HYDROS21 CTD sn H21G200002263 hasn't worked since Feb, but cond/temp seem ok. |
2012-11-29 | 20010046 | CS451 | Installed | Water Level | Installed on the Tule tower to replace sn20010026 for repair. |
2016-06-24 | 20010046 | CS451 | Removed | Water Level | Removed from the Mayberry tower for testing. Replaced with new probe from DFW system |
2010-10-27 | 2421703 | PDCR 1830-8388 | Installed | Water Level | This sensor was installed at the Mayberry site. It was installed 1.25m below the top of the plastic pipe and the top of the pipe is 71.5cm above the surface. |
2011-12-20 | 2421703 | PDCR 1830-8388 | Removed | Water Level | Removed from near the Mayberry tower due to low readings. The sensor head was silted up in the well. |
2012-01-17 | 2421703 | PDCR 1830-8388 | Installed | Water Level | Installed on the Mayberry Tule tower. |
2012-10-18 | 2421703 | PDCR 1830-8388 | Removed | Water Level | This sensor was removed from the Tule Tower due to bad readings and brought back to the lab for a check up. |
2016-06-24 | 70011229 | CS451 | Installed | Water Level | Installed on the Mayberry tower to replace the old sensor that has been acting flakey. |
2018-07-12 | 70011229 | CS451 | Removed | Water Level | Removed from MB because it had diurnal fluctuations, which seem suspect. It was replaced by sn 70011236. |
2018-07-12 | 70011236 | CS451 | Installed | Water Level | Installed at MB to replace sn 70011229, which was removed b/c of suspect diurnal fluctuations. |
2020-03-11 | 70011236 | CS451 | Notes | Water Level | Before we moved the water level sensor: Top of well to WL = 71cm Top of well to probe = 86cm After we moved the water level sensor: Top of well to WL = 69cm Top of well to probe = 91cm (therefore, water level = 22 cm) Sensor reading = 0.31 psi (x 70.41 psi/cm = 21.8 cm – good match with physical reading!) Staff gauge = 27cm |
2023-10-27 | 70011236 | CS451 | Removed | Water Level | Removed from MB because not working |
2019-09-04 | GL-136-01 | GL-136 | Installed | 0 | This new sensor is in the water next to the northeast corner post of the scaffolding. It was in about 21cm of water and about 5 cm above the bottom. Test to see if a cheap sensor can do as well as the expensive ones. |
2020-02-20 | GL-136-01 | GL-136 | Removed | 0 | Removed from MB and brought back to the lab b/c it hasn't been comparing well to the regular CSI water level sensor. |
2023-12-08 | H21G200002263 | HYDROS21 | Installed | Water Level | Installed on the northeastern corner of the Mayberry scaffolding. There's not much water right now, but I tried to install it right above the muck. |
2024-04-16 | H21G200002263 | HYDROS21 | Removed | Water Level | Removed from MB and brought back to the lab. Its depth is not working and I want to see if I can send it back to the factory for a warranty replacement. |
2024-04-23 | H21G200002263 | HYDROS21 | Installed | none | Installed on the MB floating boom |