Equipment and Calibration
Equipment history at Mayberry| ALL | | Anemometer || Barometer || Battery Bank || Camera || CH4 Probe || CO2 Probe || CO2 Transmitter || Conductivity Sensor || Data Logger || DO Sensor || Fluorometer || Forced Diffusion || Gas Analyzer || Heat Flux Plate || Infrared Temperature || Interface || LED sensor || Multiplexer || Narrow Band || Net Radiometer || PAR Sensor || Precipitation || Range Finder || RH & Temp || Soil Moisture Probe || Solar Controller || Solar Panel || Water Level |
SELECT a.recno, a.eh_date, a.eh_loc1, a.eh_loc2, IF(a.eh_loc2=:loc, a.eh_locref2, a.eh_locref1) AS ref, a.eh_locref2, a.eh_title, a.eh_notes, a.eh_id, b.serialno, b.equip, b.modelno FROM equiphist a INNER JOIN equiplist b ON a.eh_id=b.recno WHERE (a.eh_loc1=:loc1 OR a.eh_loc2=:loc2) AND b.equip=:eq ORDER BY b.serialno, a.eh_date
Date | Serial No. | Model | Action | Ref | Notes |
---|---|---|---|---|---|
RH & Temp | |||||
2023-12-22 | D4420028 | HMP45AC | Installed | RH & Temp | Installed at MB to replace HMP155 that died and was removed last visit. HMP155 cable removed this time. Met program updated for different AirT offset. |
2021-11-23 | T2820180 | HMP155 | Installed | RH & Temp | Installed on the MB tower to replace HMP45 sn U2120013 which was drifting. It was installed with a new shield and aspirated with a 12V fan. The cable on this sensor says "sn T2820183", which is different than the actual sn of the sensor, so I crossed out sn on the cable to avoid confusion. |
2023-12-08 | T2820180 | HMP155 | Removed | RH & Temp | Removed from the Mayberry tower and brought back to the lab for testing. It was reading -79 deg C and 0% RH. |
2011-11-22 | U2120013 | HMP45A | Installed | RH & Temp | Installed on the Mayberry tower to replace sn U3030041. This HMP45 has a lengthened cable to allow mounting with the recently raised eddy sensors. |
2012-04-24 | U2120013 | HMP45A | Rewired | RH & Temp | Output removed from CR1000 and swapped over to new LI-7700 sn TG1-0224 analog inputs |
2017-12-18 | U2120013 | HMP45A | Removed | RH & Temp | Removed from Mayberry for 24hour side-by-side comparison at Twitchell Alfalfa |
2017-12-19 | U2120013 | HMP45A | Removed | RH & Temp | Removed from the HMP inter-comparison at Twitchell Alfalfa and returned to Mayberry |
2019-01-24 | U2120013 | HMP45A | Serviced | RH & Temp | Short in the 12V wire at the splice point. Repaired in the field with a screw terminal, but should be brought back to the lab for a full repair. |
2019-10-22 | U2120013 | HMP45A | Repair | RH & Temp | Removed screw terminal that was currently fixing a broken wire and fixed the break with solder, heat shrink, and liquid electrical tape. |
2021-11-23 | U2120013 | HMP45A | Removed | RH & Temp | Removed from MB and brought back to the lab for testing. AirT has been drifting downward since late October.It was replaced by HMP155 sn T2820180. |