Equipment and Calibration
Equipment history at Mayberry| ALL | | Anemometer || Barometer || Battery Bank || Camera || CH4 Probe || CO2 Probe || CO2 Transmitter || Conductivity Sensor || Data Logger || DO Sensor || Fluorometer || Forced Diffusion || Gas Analyzer || Heat Flux Plate || Infrared Temperature || Interface || LED sensor || Multiplexer || Narrow Band || Net Radiometer || PAR Sensor || Precipitation || Range Finder || RH & Temp || Soil Moisture Probe || Solar Controller || Solar Panel || Water Level |
SELECT a.recno, a.eh_date, a.eh_loc1, a.eh_loc2, IF(a.eh_loc2=:loc, a.eh_locref2, a.eh_locref1) AS ref, a.eh_locref2, a.eh_title, a.eh_notes, a.eh_id, b.serialno, b.equip, b.modelno FROM equiphist a INNER JOIN equiplist b ON a.eh_id=b.recno WHERE (a.eh_loc1=:loc1 OR a.eh_loc2=:loc2) AND b.equip=:eq ORDER BY b.serialno, a.eh_date
Date | Serial No. | Model | Action | Ref | Notes |
---|---|---|---|---|---|
PAR Sensor | |||||
2018-10-25 | 010159 | PAR-LITE | Installed | PAR Sensor Incoming | Installed at MB in the incoming position to replace sn 10162, which was brought back to the lab for repair/calibration. |
2011-03-01 | 010161 | PAR-LITE | Installed | PAR Sensor Reflected Water | Installed on the Mayberry tule tower to measure PAR relfected from open water. |
2018-10-25 | 010161 | PAR-LITE | Removed | PAR Sensor Reflected Water | Removed from MB (measuring reflected water) and brought back to the lab to replace the rotted cable and for calibration. It was replaced by sn 040412. |
2019-07-25 | 010161 | PAR-LITE | Installed | PAR Sensor Reflected Water | Installed at MB (PAR reflected water) to replace sn 040412, which was brought back to the lab for testing. |
2024-01-11 | 010161 | PAR-LITE | Removed | PAR Sensor Reflected Water | Removed from MB tower because it was no longer measuring open water (wetland is filling in with cattails) |
2011-03-01 | 010163 | PAR-LITE | Installed | PAR Sensor Reflected Veg | Installed on the Mayberry tule tower measuring PAR reflected from tules. |
2015-01-15 | 010163 | PAR-LITE | Removed | PAR Sensor Reflected Veg | Removed from the Mayberry tower (tule position) for repair due to INF reading. |
2015-03-05 | 010163 | PAR-LITE | Installed | PAR Sensor Reflected Veg | Installed on the Mayberry tower (over tules) but it was reading high when it was connected to the multiplexor. The mux channel was even read high when jumped - so may be bad channel on mux. The PAR sensor was left on the tower and the mux or program will be changed to deal with the bad channel. |
2018-10-25 | 040412 | PAR-LITE | Installed | PAR Sensor Reflected Water | Installed at MB (measuring reflected water) to replace sn 010161, which was brought back to the lab for repair/calibration. |
2019-07-25 | 040412 | PAR-LITE | Removed | PAR Sensor Reflected Water | Removed from MB (PAR reflected water) and brought back to the lab for testing (spiky). It was replaced by sn 010161. |
2011-03-01 | 10162 | PAR-LITE | Installed | PAR Sensor Incoming | Installed on the Mayberry tule tower measuring incoming PAR. |
2018-10-25 | 10162 | PAR-LITE | Removed | PAR Sensor Incoming | Removed from MB and brought back to the lab to replace the rotted cable and for calibration. It was replaced by sn 010159. |
2021-10-21 | Q100420 | LI-190/R | Installed | PAR Sensor Diffuse PAR | Installed as part of the rotating shadow band for diffuse PAR - not working until 11-04 |
2024-08-15 | UWQ11698 | LI-192 | Installed | none | Installed on the eastern edge of some cattails bout 5m east of the tower and about 50cm below the current water level. It is wired to an extension box about 3m from the tower. |