| ALL | | Anemometer || Barometer || Battery Bank || Camera || CO2 Probe || Data Logger || Forced Diffusion || Gas Analyzer || Heat Flux Plate || Infrared Temperature || Interface || LED sensor || Moisture Point || Multiplexer || Narrow Band || Net Radiometer || PAR Sensor || Precipitation || Radio || RH & Temp || Soil Moisture Probe || Soil Water Potential || Solar Controller || Solar Panel || Water Level || Weather Station |

SELECT a.recno, a.eh_date, a.eh_loc1, a.eh_loc2, IF(a.eh_loc2=:loc, a.eh_locref2, a.eh_locref1) AS ref, a.eh_locref2, a.eh_title, a.eh_notes, a.eh_id, b.serialno, b.equip, b.modelno FROM equiphist a INNER JOIN equiplist b ON a.eh_id=b.recno WHERE (a.eh_loc1=:loc1 OR a.eh_loc2=:loc2) AND b.equip=:eq ORDER BY b.serialno, a.eh_date

Date Serial No. Model Action Ref Notes
Moisture Point
2001-11-10 000000402165 PRB-K Type #8 Installed Installed near the understory tower by Dennis and Liukang
2001-11-10 000000402FF3 PRB-K Type #8 Installed Installed near the water potential table and original sap flow measurements by Dennis and Liukang
2021-02-10 000000402FF3 PRB-K Type #8 Removed Soil Moisture Probe F -0.50m Removed from Tonzi floor due to fixed readings for a long while. This sensor was out of the ground at the edge of the trees near the path to the tower. It was buried vertically with the top of the sensor 31cm below the surface - the time were 44-50cm below the surface.
2001-11-10 000000574632 PRB-K Type #8 Installed Installed near the soil co2 measurements tower by Dennis and Liukang
2017-12-14 000000574632 PRB-K Type #8 Removed Removed from the location inside the soil co2 profile fence. This probe has been giving bad readings for a while and its lowest pin is broken off.
2001-11-10 000000574B4B PRB-K Type #8 Installed Installed near the Floor solar panels by Dennis and Liukang
2019-12-03 000000574B4B PRB-K Type #8 Removed Removed from Tonzi near the Floor solar panels. This probe has three broken pins and has not been measured in a long time but this was the first time the soil was wet enough to remove it by hand.
2015-04-08 00000128B8072 PRB-K Type #8 Installed Installed in a location near the main tower ground sensors to replace sn 000007931AFE that has a broken pin.
2016-11-17 00000128B8072 PRB-K Type #8 Removed Removed from Tonzi near the main tower. This probe has two broken pins.
2015-04-08 000007931AFE PRB-K Type #8 Removed Removed from a location near the main tower ground sensors due to a broken pin (2nd from bottom). Replaced by sn 00000128B8072
2003-04-16 0000097A3B40 PRB-K Type #8 Installed Installed at Tonzi second closest to big tree by Liukang
2003-04-16 0000097A3C6E PRB-K Type #8 Installed Installed at Tonzi third closets to big tree by Liukang
2003-04-16 0000097A432E PRB-K Type #8 Installed Installed at Tonzi furthest from big tree by Liukang
2003-04-16 0000097A4AAA PRB-K Type #8 Installed Installed at Tonzi closest to big tree by Liukang
2005-01-27 00000A3D04E8 PRB-K Type #8 Installed Installed at Tonzi by minirhizotron transect west of soil CO2 profiles
2024-01-02 00000A3D04E8 PRB-K Type #8 Removed none This probes has been broken for a long time - more than a year. Removed. It has a broken pin and the shaft is cracked.
2005-01-27 00000A6D72F5 PRB-K Type #8 Installed Installed at Tonzi by minirhizotron transect west of soil CO2 profiles
2005-01-27 00000A6D882B PRB-K Type #8 Installed Installed at Tonzi by minirhizotron transect west of soil CO2 profiles
2016-11-17 00000FEDDAA1 PRB-K Type #8 Installed Installed at Tonzi near the main tower to replace sn 00000128B8072 that has two broken pins