Equipment and Calibration
Equipment history at Mayberry| ALL | | Anemometer || Barometer || Battery Bank || Camera || CH4 Probe || CO2 Probe || CO2 Transmitter || Conductivity Sensor || Data Logger || DO Sensor || Fluorometer || Forced Diffusion || Gas Analyzer || Heat Flux Plate || Infrared Temperature || Interface || LED sensor || Multiplexer || Narrow Band || Net Radiometer || PAR Sensor || Precipitation || Range Finder || RH & Temp || Soil Moisture Probe || Solar Controller || Solar Panel || Water Level |
SELECT a.recno, a.eh_date, a.eh_loc1, a.eh_loc2, IF(a.eh_loc2=:loc, a.eh_locref2, a.eh_locref1) AS ref, a.eh_locref2, a.eh_title, a.eh_notes, a.eh_id, b.serialno, b.equip, b.modelno FROM equiphist a INNER JOIN equiplist b ON a.eh_id=b.recno WHERE (a.eh_loc1=:loc1 OR a.eh_loc2=:loc2) AND b.equip=:eq ORDER BY b.serialno, a.eh_date
Date | Serial No. | Model | Action | Ref | Notes |
---|---|---|---|---|---|
Anemometer | |||||
2011-04-26 | 000019 | WMP 1352 | Installed | Anemometer | Installed on the Mayberry tower to replaced sn 000022 that had stopped sending data. |
2012-04-24 | 000019 | WMP 1352 | Removed | Anemometer | Removed from the Mayberry eddy tower. Replaced with WM sonic sn 074417 |
2010-10-14 | 000022 | WMP 1352 | Installed | Anemometer | Installed as part of a new tower at the new Mayberry wet land site. |
2012-04-24 | 074417 | WM 1590 | Installed | Anemometer | Installed on the Mayberry eddy tower the new Licor GHG system to swap out WMP sonic sn 000019. The old sonic did not have analog output, the new one does. |
2017-01-26 | 074417 | WM 1590 | Removed | Anemometer | Removed from Mayberry tower so we could take it back to the lab for firmware upgrade. It was replaced by sn 153804. |
2017-01-26 | 153804 | WM 1590 | Installed | Anemometer | Installed at Mayberry tower. It replaced sn 074417. |
2022-01-02 | 153804 | WM 1590 | Removed | Anemometer | Removed from the MB tower and brought back to the lab for testing. The SOS was bad. Before removing, I measured a heading of 26 deg true N on my phone compass. |
2022-01-02 | 153805 | WM 1590 | Installed | Anemometer | Installed on the MB to replace sn 153804, which was removed b/c of bad SOS numbers. This sonic was installed at a heading of 23 deg true N as measured by my phone compass. |
2022-07-26 | 153805 | WM 1590 | Removed | Anemometer | Removed from MB tower for inspection back at the lab. The sonic heading was 7 deg true N before removal. |
2022-08-01 | 153805 | WM 1590 | Installed | Anemometer | Installed on MB after testing in the lab. Sonic heading = 10 deg true N. |