Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Processing Notes

<--2024-03-30 |

Gilbert Tract: 2024-04-19

Author: Joe Verfaillie
Processing: 2024-01-01 (1) to 2024-04-09 (100) , Met
Title: 2024 first quarter met cleaning

10 Relevant Fieldnotes
8 Relevant Equipment Notes
1 Stream log entries found
View processing options

Cleaning met for 2024 quarter 1

GT_met

Most channels have some drop outs in early April where the CTD water level sensor had its cable chew and shorted out.

AirT - Big gap at the end caused by the shorted water level sensor.  li77_temp is a good fill but might have to wait until next field visit to bridge the gap.

AtmPres - okay, some random negative spikes, some bad data where the water level was shorted.

depth_CTD - big gap starting in the early morning of 3/31 when and animal chewed the cable in half.  The lowest tides are still showing the slow drain so may be have to gap fill.

DifPar, totPAR - big gap most of January where the proximity sensor was broken.  A lot of scattered mostly single a few double missing points the rest of the year - interpolated.

LW_in, out - okay, water level short gaps filled

NR01_PRT - okay, no water level short gaps

PAR_in, out - okay, water level short gap fills were cloudy days hard to get great fills.

Rain - okay

RH - might need to wait for next batch of data to fill water level short gap at end of period.

SHF1-3 - not sure how I'm going to fill these.  Looks like pretty smooth curves but found anything that matches yet.

 

 
 

Login
Select Notes:



This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.