Field Notes

<--2004-12-09 09:00:00 | 2004-12-15 13:50:00-->

Tonzi: 2004-12-10 10:00:00 (DOY 345)
Author: Ted Hehn
Others:

Summary: Problems connecting to Tower co2 profile CR10X7, new battery from CR10X4 (sap Flow), new HMP fan

When: Wed-Thurs 10Dec04
Where: Tonzi/Vaira Ranches
Who: Ted Hehn
Weather – Recent rains, cool and clear

10Dec04

Unable to reestablish communication with CR10x7 (co2 profile system). Begin diagnostics. I was able to gain communication with CR10x8 which is also at top of tower on same coax line. Investigate connections and I discovered that one of the connections was made without a center pin. Only the center wire is present. This needs to be corrected. Unable to determine problem: need diagnostic equipment from the Lab.

Install new battery on CR10x4 (Sapflow).

Install new fan on tower in T & RH rad shield.

Reset the watchdog timer to activate at 290 minutes.

Misc Notes
Bring SC532 interface & laptop for cr10x7 diagnostics.
Bring BNC connectors
Bring coax cable 100 ft

Field Data

No tank data

No TZ Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

No TZ Tree DBH found

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Explore the graph:Tonzi Tower Met: Temperature and Power in a new window

Explore the graph:Tonzi Tower Met: Solar Radiation in a new window

Explore the graph:Tonzi Tower Met: IRT Sensors in a new window

Explore the graph:LED Sensor Incoming in a new window

Explore the graph:LED Sensor Outgoing in a new window

Explore the graph:4-Band Solar Radiation in a new window

Explore the graph:Air Temperature Profile in a new window

Explore the graph:Relativity Humidity Profile in a new window

Explore the graph:Tonzi Tower PRI in a new window

Explore the graph:SRS PRI/NDVI in a new window

Explore the graph:SRS NDVI in a new window

No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found

Explore the graph:Tonzi PPT in a new window

Explore the graph:Tonzi CO2 and H2O Densities in a new window

Explore the graph:Air Pressure in a new window

No data found for TZ_fflux.
8 TZ_fmet graphs found

Explore the graph:Soil Heat Flux in a new window

Explore the graph:Tonzi Soil Temperature Set A in a new window

Explore the graph:Tonzi Soil Temperatures Set B in a new window

Explore the graph:Tonzi Soil Temperatures Set C in a new window

Explore the graph:Tonzi Soil Temperature Set D in a new window

Explore the graph:Well Level in a new window

Explore the graph:Well Water Temperature in a new window

Explore the graph:Soil Water Potential in a new window

No data found for TZ_tram.
No data found for TZ_co2prof.
No data found for TZ_irt.
1 TZ_windprof graphs found

Explore the graph:Wind Speed Profile in a new window

No data found for TZ_tflux.
2 TZ_sm graphs found

Explore the graph:Floor Solar Radiations in a new window

Explore the graph:TZ Soil Moisture in a new window

Can't check TZ_met
1 TZ_met graphs found

Explore the graph:Floor and Tower RH in a new window

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration