Field Notes
<--2004-08-17 10:30:00 |
2004-09-08 10:15:00-->
Other sites visited today:
Vaira
Phenocam link:
Searching...Tonzi: 2004-08-27 10:45:00 (DOY 240)
Author: Siyan Ma
Others: Lorraine
Summary: 2 days lost on Floor eddy, Tower co2 profile cell temp low, no moisture point readings - dead battery,
When: Date: Aug. 27, 2004, Day: 240, Watch Time: 10:45 am Where: Tonzi/Vaira Ranch Who: Siyan and Lorraine Weather: Sunny, hot, breeze on the tower Phenology: dead grass; Oak leaves more yellow.
Summary & Problems
- Tower site computer was frozen on D238, so we lost 2-day data on Tower site. Floor and Vaira computer worked well and no data gap.
- Solar panel’s Amps = 0.0 amps. Something wrong with the power system?
- CO2 profile cell temp around 35 oC (< 50oC).
- TDR instrument didn’t work. The readings were always the same in the range 31 – 39 for different probes in Vaira and Tonzi. Voltage = 11.1v. Is Battery dead?
- Floor Laptop screen was flashing frequently.
Tonzi_Tower Site
- Fence and gate power: >12.0 v.
- Panel and Batteries: 14.2 v; 0.0 amps; 4.0 amps.
- When we got the site, the PC laptop wasn’t on. Frozen file: TW4_238.flx
- Reading from Gillsonic screen after restart. (The value of H2O and CO2 should be in the range of 0 – 5 v.)
Time |
(Restart) 11:10:35 |
Path/File name |
TW_240.flx |
|
mean |
std |
|
mean |
std |
w |
-0.65 |
0.848 |
Ts |
34.848 |
2.135 |
u |
1.84 |
0.882 |
H2O |
1.512 |
0.035 |
v |
3.53 |
1.077 |
CO2 |
1.5 |
0.018 |
- Download data. (Alt_X to close Gillsonic.exe; close PC208W before copying.)
- Check calibration cylinders:
CO2 2000 psig; flow 8 psi. N2 900 psig; flow 10.0 psi.
- Checking CR10X and CR23X:
CR10X OK. CR23X – NR_2 = -9999.
Toniz_Floor Site
- Fence and gate power: >12.0 v.
- Panel and Batteries: 13.7 v; 14.4 amps; 2.7 amps.
- Laptop screen was flashing frequently.
- Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)
Time |
11:30:17 |
Path/File name |
FL4_240.flx |
|
mean |
std |
|
mean |
std |
w |
0.07 |
|
Ts |
34.48 |
|
u |
0.71 |
|
H2O |
1.87 |
|
v |
1.26 |
|
CO2 |
1.47 |
|
- Download data OK. Readings were OK from Gillsonic screen after downloading OK. The screen of PC was flashing.
- Check MD-9 system connections. OK.
- CO2 profile: cell temp still was lower than supposed 50oC.
- Close gate and set up fence.
|
Field Data
No tank data
No TZ Well data found
No TZ Moisture Point data found
No VR Moisture Point data found
No TZ grass heigth found
No VR grass heigth found
No TZ Tree DBH found
No water potential data found
No TZ Grass Biomass data found
No TZ OakLeaves Biomass data found
No TZ PineNeedles Biomass data found
0 photos found
16 sets found
No data found for TZ_Fenergy.
11 TZ_tmet graphs found
No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found
No data found for TZ_fflux.
8 TZ_fmet graphs found
No data found for TZ_tram.
No data found for TZ_co2prof.
No data found for TZ_irt.
No data found for TZ_windprof.
No data found for TZ_tflux.
2 TZ_sm graphs found
Can't check TZ_met
1 TZ_met graphs found
Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data