Field Notes

<--2004-01-30 00:00:00 | 2004-03-05 13:00:00-->
Other sites visited today: Tonzi
Phenocam link: Searching...

Vaira: 2004-03-04 10:00:00 (DOY 64)
Author: Ted Hehn
Others:

Summary: Removed solar and battery fuses, disturbed theta probe, added radiation calibration sensors

When: Thurs 4Mar04, JD-64
Where: Tonzi/Vaira Ranches
Who: Ted Hehn
Weather Clear and warm.

Vaira Ranch:

Site down upon arrival – down for 12 days battery I/O fuse holder melted and lost continuity, the fuse was intact only the contacts were melted. Remove fuse holders on both solar input and on battery I/O. Last time the solar input fuse holder burned.
Fuse holders were left on load output fused to 7.5 amp.

Clean diffuse radiation sensor lens and both 4way rad sensors.

Power up flux platform and LVD LED flashing red indicating depleted battery status.

Stepped on of the soil moisture probes (Theta) and it was jarred loose.

Reg status V=12.0, SA= 29.2 with 8 panels, remove 2 panels and amps drop to 22.6

Calibration sensors:
Pyranometer: 4.90 uV/W m-2, sn 996985, Univ sn= 991007043
Net Rad: 14.1 uV/W m2, sn 021029
Par up: 5.28 umol/m2 s, sn 010164
Par Dn: 5.52 umol/m2 s, sn 010162

Vaira sensors
Pyranometer: uV/W m-2, sn
Net Rad: 12.3uV/W m2, sn 990353
Par up: 5.03 umol/m2 s, sn 990025
Par Dn: 5.08 umol/m2 s, sn 990031

Field Data

No tank data

No VR Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

No VR Tree DBH found

No water potential data found

No VR Grass Biomass data found

No VR OakLeaves Biomass data found

No VR PineNeedles Biomass data found

0 photos found

Graphs display:
9 sets found

16 VR_met graphs found

Explore the graph:Temperatures in a new window

Explore the graph:System Power Voltage in a new window

Explore the graph:Soil Temperatures Set 1 in a new window

Explore the graph:Soil Temperatures Set 2 in a new window

Explore the graph:Soil Temperature Set 3 in a new window

Explore the graph:Soil Temperature at -4cm in a new window

Explore the graph:Soil Heat Flux in a new window

Explore the graph:Soil Moisture in a new window

Explore the graph:Photosynthetic Active Radiation in a new window

Explore the graph:Short/Long Wave Radiation in a new window

Explore the graph:LED sensor in a new window

Explore the graph:Vaira PPT in a new window

Explore the graph:Peltier SHF Plates in a new window

Explore the graph:Peltier SHF Temperatures in a new window

Explore the graph:LED NDVI in a new window

Explore the graph:NDVI SRS Raw Data in a new window

No data found for VR_flux.
No data found for VR_soilco2.
No data found for VR_pond.
Can't check TZVR_mixed
No data found for VR_fd.
No data found for VR_processed.
No data found for VR_arable.
No data found for VR_soilvue.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration