Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Field Notes

<--2007-11-20 00:00:00 | 2007-12-21 00:00:00-->

Tonzi: 2007-11-29 10:00:00 (DOY 333)
Author: Siyan Ma
Others: Rodrigo


When: Date: 11/29/2007 , Day: 333 , Watch Time: 10:00 .
Where: Tonzi/Vaira Ranch
Who: Siyan and Rodrigo
Weather: clear, nice cold
Phenology: Vaira grass almost covered 100% area, but standing litters were still thick. Overall, the grassland is in yellow. Tonzi’s grass covered about 70%. Some blue oak’s leaves were still green.
Summary
  1. EC system at Tower and Vaira were working well. Floor computer didn’t reboot properly in the morning on Day 325. So, flux data were lost between Day 325-333. Ted reported low power problem after his last visit. Maybe we have to add two more batteries at Floor site to solve the winter power problem. Met data are good.
  2. Voltage meter of Vaira fence looks broken because the pointer was always on the far right side even though the switch was off.
  3. CO2 Tank was low, around 200 psig.
  4. Grass samples were collected for LAI and phenology in Tower and Vaira, oak leaves sample for N.
  5. Dendrometer – tree stem enlarged 3mm since Nov. 07, 2007.
  6. Plan to take spectrum measurement, but forget charging laptop’s battery. Sorry!
  7. Rodrigo helped to do soil TDR measurement and found that same readings for time delay but reported different soil moisture values. Matteo noticed the problem at Shieman Island, too.


Vaira_Grass Site
  1. Fence and gate power: >12 v.
  2. Panel and Batteries: 13.3 v; 0.0 amps; 4.7 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\V07_ 333 .flx
D:\Data\VR07 .raw


mean

std


mean

std

w

0.18

0.238

Ts

13.9

0.354

u

0.91

0.360

H2O

1.8

0.030

v

-0.25

0.326

CO2

2.14

0.020




Tc

1.001

0.057
  1. downloading data – Yes.
  2. check the fans of air temp. and relative humidity sensors at Vaira. OK.
  3. Check MD-9 system connections. OK.
  4. Check levels of Radiation sensors, clear up surfaces. Yes.
  5. Closed gate and set up fence. - Voltage meter of Vaira fence looks broken because the pointer was always on the far right side even though the switch was off.

Tonzi_Tower Site

  1. Fence and gate power: Gate was open! v.
  2. Panel and Batteries: 13.9 v; 15.1 amps; 2.9 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\T07_ 333 .flx
D:\Data\TW07 .raw


mean

std


mean

std

w



Ts



u



H2O



v



CO2


  1. downloading data Yes.
  2. check the fans of air temp. and relative humidity sensors on the tower and the floor.
  3. Check calibration cylinders;

CO2 200 psig; flow 20 psi.
N2 700 psig; flow 20 psi.
Manually calibrate Li-800. Following Ted’s instruction: H:\IoneSavanna_2004\Tower_2004\CO2Profile\LI800_Calibration_Procedure_2Nov04.txt
Is the pump running‌ Yes.
How to check the CO2 values‌ Click “Ports/Flags” button to see which ports or flags is setting high. Pressure should be less than ambient value. When Flag 8 is high, it may indicate that RRR’s battery is low.
  1. close gate and set up fence. Yes.

Toniz_Floor Site
  1. Fence and gate power: >12 v.
  2. Panel and Batteries: 13.6 v; 14.4 amps; 2.3 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\F07_ 333 .flx
D:\Data\FL07 .raw


mean

std


mean

std

w

-0.01

0.272

Ts

13.79

0.852

u

1.67

1.65

H2O

2.45

0.126

v

0.47

0.765

CO2

1.69

0.081
  1. downloading data. Yes.
  2. Check MD-9 system connections. GOOD.

CR23X3 – floor-Met
CR23X5 – soil CO2 profile
CR23X6 – tower-Met
CR10X2 – floor-Met
CR10X4 – sap-flow
CR10X7 – CO2 profile
CR10X8 – wind profile
  1. Soil CO2 profile: in the lab
  2. Close gate and set up fence. Yes.

tonzi

7931AFE

402165

574B4B

402FF3

574632

7A432E

7A3C6E

7A3B40

7A4AAA

29-Nov-07

333










SM









0-15

9.8

7.9

25.6

13.2

11.6

11.2

14.5

5.9

7.8

15-30

13.2

14.3

16.2

17.1

13.5

9.2

17.4

14.2

4.4

30-45

17.5

7.1

5.4

14.2

1.7

8.8

13.2

16.5

13.0

45-60

11.7

3.6

8.5

8.7

15.1

10.5

11.3

15.4

9.6












A6D882B

A3D04E8

A6D72F5

















0-15

21.1

16.5

6.3







15-30

11.8

10.3

14.9







30-45

14.3

16.2

12.2







45-60

13.0

5.5

2.6

















vaira

57318a

7933dee








0-15

2.2

5.5








15-30

9.7

13.6








30-45

8.9

11.9








45-60

14.9

15.3









Tonzi




Dendrometer







Date

Day

Tag #

Reading (cm)

11/29/2007

333

71

Broken



72

4.2



77

Broken



78

Broken



79

8.1



245

-0.1



248

9.7



250

7.4



255

Broken



‌252‌

missing



102

4.0


Field Data

No tank data

No TZ Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

No data found for TZ_fflux.
8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

No data found for TZ_tram.
3 TZ_co2prof graphs found

Tower CO2 Profile Concentrations

Tower CO2 Profile Cell Pressure

CO2 Profile Sensor Temperature

No data found for TZ_irt.
1 TZ_windprof graphs found

Wind Speed Profile

No data found for TZ_tflux.
2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met
1 TZ_met graphs found

Floor and Tower RH

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.