Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Field Notes

<--2007-10-24 10:30:00 | 2007-11-20 00:00:00-->

Tonzi: 2007-11-07 10:15:00 (DOY 311)
Author: Siyan Ma
Others:


When: Date: 11/07/2007 , Day: 311 , Watch Time: 10:15am .
Where: Tonzi/Vaira Ranch
Who: Siyan
Weather: clear, hot
Phenology: The sites still looked yellow overall. Young grasses that germinated under litters got dry again. No new germination yet. Some big oak trees (e.g. Liukang’s tree) produced acorns this year, and their leaves were still green. Collected some acorns under Liukang’s tree (#92) and around Tree #11.
Summary
  1. CO2 tank is very low (~400 psi).
  2. Three towers worked well.
  3. RRR parked 1 m away from the other end of charge-station. I followed Ted’s instruction, disconnected battery and took the whole cart back to the lab.
  4. Sampled senescent oak leaves for Stefania’s nitrogen resoption testing.
  5. Took spectrometer measurement at Vaira and Tonzi.
  6. Took TDR probe measurement.

Vaira_Grass Site
  1. Fence and gate power: 12 v.
  2. Panel and Batteries: 13.8 v; 13.7 amps; 1.7 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\V07_ 311 .flx
D:\Data\VR07 .raw


mean

std


mean

std

w

0.15

0.22

Ts

21.8

0.72

u

0.30

0.21

H2O

1.84

0.026

v

0.97

0.71

CO2

1.88

0.027




Tc

2.09

0.112
  1. I did not downloaded data because I forgot bring the memory drive.
  2. check the fans of air temp. and relative humidity sensors at Vaira. OK.
  3. Check MD-9 system connections. OK.
  4. Closed gate and set up fence. Yes.

Tonzi_Tower Site

  1. Fence and gate power: >12 v.
  2. Panel and Batteries: 13.3 v; 0.0 amps; 4.1 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\T07_ 311 .flx
D:\Data\TW07 .raw


mean

std


mean

std

w

0.35

0.4

Ts

23.1

0.45

u

0.78

0.6

H2O

2.07

0.01

v

1.7

0.5

CO2

1.056

0.017
  1. downloading data (Not)
  2. check the fans of air temp. and relative humidity sensors on the tower and the floor.
  3. Check calibration cylinders;

CO2 500 psig; flow 20 psi.
N2 1000 psig; flow 20 psi.
Manually calibrate Li-800. Following Ted’s instruction: H:\IoneSavanna_2004\Tower_2004\CO2Profile\LI800_Calibration_Procedure_2Nov04.txt
Is the pump running‌ Yes
  1. CR10X7 – CO2 profile

394.3

394.9

395.3

395.3

948.7

942.5

943.3

942.8

45.0

45.1

45.1

45.2

49.7

49.8

49.8

49.7


-3.48

421.5

948.5

946

43.8

43.4

49.4

49.4


How to check the CO2 values‌ Click “Ports/Flags” button to see which ports or flags is setting high. Pressure should be less than ambient value. When Flag 8 is high, it may indicate that RRR’s battery is low.
  1. close gate and set up fence. OK.

Toniz_Floor Site
  1. Fence and gate power: 12 v.
  2. Panel and Batteries: 13.5 v; 9.0 amps; 2.0 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\F07_ 311 .flx
D:\Data\FL07 .raw


mean

std


mean

std

w

0.2

0.324

Ts

23.45

0.213

u

-0.75

0.275

H2O

2.2

0.088

v

0.95

0.502

CO2

1.7

0.025
  1. Check MD-9 system connections. OK.
  2. Soil CO2 profile: probes are in the lab for calibration.
  3. Close gate and set up fence. Yes.




Soil Moisture











vaira

57318a




7933dee





0-15

3.9

3.6

3.9


8.8

9.7

9.4



15-30

5.1

4.8

5.4


6.9

7.2

6.6



30-45

10.1

10.1

10.1


11.5

11.5

11.5



45-60

12.5

12.8

12.2


16.8

15.3

15.3













  1. Close gate and set up fence.

Tonzi




Dendrometer







Date

Day

Tag #

Reading (cm)

11/07/2007

311

71

Broken



72

1.9



77

Broken



78

Broken



79

6.2



245

3.8



248




250

4.0



255




‌252‌

Missing



102

3.8


Field Data

No tank data

No TZ Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

No data found for TZ_fflux.
8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

No data found for TZ_tram.
3 TZ_co2prof graphs found

Tower CO2 Profile Concentrations

Tower CO2 Profile Cell Pressure

CO2 Profile Sensor Temperature

No data found for TZ_irt.
1 TZ_windprof graphs found

Wind Speed Profile

No data found for TZ_tflux.
2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met
1 TZ_met graphs found

Floor and Tower RH

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.