Field Notes
<--2007-02-04 11:30:00 |
2007-03-06 00:00:00-->
Phenocam link:
Searching...Tonzi: 2007-03-02 09:30:00 (DOY 61)
Author: Siyan Ma
Others: Youngryel
When: Date: 3/2/2007 , Day:
61 , Watch Time: 9:30am .
Where: Tonzi/Vaira Ranch
Who: Siyan and Young-Ryel
Weather:
clear, very windy on the top of the tower
Phenology:
green grass, more germination after recent rains, grass starts taking up
carbon!
Summary
- Check EC system, swap Li-7500
at all three sites, and download data.
All is well.
- Radiation Tram was parking in
the middle of the track.
- Power on Floor site is
OK.
- Soil CO2 profile
worked well, but no power on the
fences. Didn’t find broken wire
- dendrometer, soil moisture, and
spectrume were measured.
Dendrometers need reset because some have been out of range!!!
Vaira_Grass
Site
- Fence and gate power: >12 v.
- Panel and Batteries: 14.0 v; 13.9 amps; 2.5 amps.
- Reading from Gillsonic screen
before downloading data. (The value
of H2O and CO2 should be in the range of 0 – 5 v.)
Time
|
9:39:56
|
Path/File name
|
D:\Data\V07_061.flx
D:\Data\VR070610930.raw
|
|
mean
|
std
|
|
mean
|
std
|
w
|
0.65
|
0.334
|
Ts
|
13.64
|
0.93
|
u
|
1.57
|
0.4
|
H2O
|
1.6
|
0.127
|
v
|
1.69
|
0.606
|
CO2
|
2.1
|
0.039
|
|
|
|
TC
|
0.43
|
0.051
|
- downloading data OK
- swaping Li-7500: remove #41,
install #73
- clean up the surfaces of
Delta PAR sensor, KZ PARs, 4-way radiation sensors.
- check CR23X: BUSY WITH COM.
- spectrometer measurement was
taken by Youngryel.
- Closed gate and set up fence.
Tonzi_Tower Site
- Fence and gate power: >12 v.
- Panel and Batteries: 13.3
v; 0.0 amps; 5.8 amps.
- Reading from Gillsonic screen
before downloading data. (The value
of H2O and CO2 should be in the range of 0 – 5 v.)
Time
|
|
Path/File name
|
D:\Data\T07_061 .flx
D:\Data\TW07061.raw
|
|
mean
|
std
|
|
mean
|
std
|
w
|
-0.37
|
0.04
|
Ts
|
15.9
|
0.21
|
u
|
4.24
|
1.206
|
H2O
|
1.695
|
0.018
|
v
|
-1.0
|
1.539
|
CO2
|
2.704
|
0.054
|
- downloading data OK
- swaping Li-7500: remove #065,
install #0976.
- check the fans of air temp.
and relative humidity sensors on the tower and the floor.
- Check calibration cylinders;
CO 2 900 psig; flow 18
psi.
N 2 1200
psig; flow 20 psi.
Manually calibrate Li-800. Following Ted’s instruction: H:\IoneSavanna_2004\Tower_2004\CO2Profile\LI800_Calibration_Procedure_2Nov04.txt
Is the pump running OK
- close gate and set up fence. OK
Toniz_Floor
Site
- Fence and gate power: 12
v.
- Panel and Batteries: 13.7
v; 10.4
amps; 1.8 amps.
- Reading from Gillsonic screen
before downloading data. (The value
of H2O and CO2 should be in the range of 0 – 5 v.)
Time
|
11:53:39
|
Path/File name
|
D:\Data\F06_ 061
.flx
D:\Data\FL0761
.raw
|
|
mean
|
std
|
|
mean
|
std
|
w
|
1.0
|
0.545
|
Ts
|
15.8
|
0.804
|
u
|
1.9
|
0.945
|
H2O
|
1.9
|
0.117
|
v
|
1.2
|
0.620
|
CO2
|
2.03
|
0.07
|
- downloading data: OK
- Check MD-9 system connections:
OK
CR23X3 – floor-Met
CR23X5 – soil CO 2
profile
CR23X6 – tower-Met
CR10X2 – floor-Met
CR10X4 – sap-flow
CR10X7 – CO 2 profile
CR10X8 – wind profile
CR1021 – Xingyuan’s sap flow
- Soil CO2 profile
Reading
from datalogger
Panel
temp
|
19.9
|
|
|
Battery
voltage
|
13.5
|
|
|
CO2E_1
|
1171.3
|
TCE_1
|
15.0
|
CO2W_1
|
648
|
TCW_1
|
13.3
|
CO2E_2
|
1764
|
TCE_2
|
16.6
|
CO2W_2
|
927
|
TCW_2
|
11.0
|
CO2E_3
|
1720
|
TCE_3
|
11.6
|
CO2W_3
|
2839
|
TCW_3
|
11.3
|
CO2E_4
|
1981
|
TCE_4
|
9.3
|
CO2W_4
|
4251
|
TCW_4
|
11.6
|
- soil moisture (TDR)
tonzi
|
7931AFE
|
402165
|
574B4B
|
402FF3
|
574632
|
7A432E
|
7A3C6E
|
7A3B40
|
7A4AAA
|
2-Mar-07
|
61
|
|
|
|
|
|
|
|
|
|
SM
|
|
|
|
|
|
|
|
|
0-15
|
40.8
|
34.2
|
44.8
|
29.4
|
38.1
|
35.1
|
28.3
|
26.0
|
20.5
|
15-30
|
43.5
|
40.8
|
40.9
|
40.1
|
41.1
|
33.4
|
29.7
|
33.9
|
20.8
|
30-45
|
39.7
|
43.8
|
43.4
|
43.2
|
49.3
|
36.0
|
32.4
|
34.2
|
35.4
|
45-60
|
43.4
|
62.1
|
57.2
|
45.0
|
40.4
|
35.6
|
45.0
|
46.6
|
32.8
|
|
|
|
|
|
|
|
|
|
|
|
A6D882B
|
A3D04E8
|
A6D72F5
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0-15
|
38.7
|
34.2
|
24.1
|
|
|
|
|
|
|
15-30
|
26.0
|
32.1
|
34.9
|
|
|
|
|
|
|
30-45
|
36.0
|
36.4
|
37.3
|
|
|
|
|
|
|
45-60
|
43.6
|
49.9
|
49.6
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
vaira
|
57318a
|
7933dee
|
|
|
|
|
|
|
|
0-15
|
24.2
|
28.4
|
|
|
|
|
|
|
|
15-30
|
28.7
|
32.3
|
|
|
|
|
|
|
|
30-45
|
31.8
|
32.4
|
|
|
|
|
|
|
|
45-60
|
33.6
|
38.0
|
|
|
|
|
|
|
|
- Close gate and set up fence.
Tonzi
|
|
|
|
Dendrometer
|
|
|
|
|
|
|
Date
|
Day
|
Tag #
|
Reading (cm)
|
3/2/2007
|
61
|
71
|
23.9
|
|
|
72
|
23.5
|
|
|
77
|
Broken
|
|
|
78
|
Broken
|
|
|
79
|
23.5
|
|
|
245
|
22.7
|
|
|
248
|
Out of range
|
|
|
250
|
21.9
|
|
|
255
|
22.4
|
|
|
252
|
missing
|
|
|
102
|
Broken
|
|
Field Data
No tank data
No TZ Well data found
No TZ Moisture Point data found
No VR Moisture Point data found
No TZ grass heigth found
No VR grass heigth found
No TZ Tree DBH found
No water potential data found
No TZ Grass Biomass data found
No TZ OakLeaves Biomass data found
No TZ PineNeedles Biomass data found
0 photos found
16 sets found
No data found for TZ_Fenergy.
11 TZ_tmet graphs found
No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found
No data found for TZ_fflux.
8 TZ_fmet graphs found
No data found for TZ_tram.
3 TZ_co2prof graphs found
No data found for TZ_irt.
1 TZ_windprof graphs found
No data found for TZ_tflux.
2 TZ_sm graphs found
Can't check TZ_met
1 TZ_met graphs found
Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data