Field Notes

<--2007-02-04 11:30:00 | 2007-03-06 00:00:00-->
Phenocam link: Searching...

Tonzi: 2007-03-02 09:30:00 (DOY 61)
Author: Siyan Ma
Others: Youngryel


When: Date: 3/2/2007 , Day: 61 , Watch Time: 9:30am .
Where: Tonzi/Vaira Ranch Radiometer tram at Tonzi
Who: Siyan and Young-Ryel
Weather: clear, very windy on the top of the tower
Phenology: green grass, more germination after recent rains, grass starts taking up carbon!
Summary
  1. Check EC system, swap Li-7500 at all three sites, and download data. All is well.
  2. Radiation Tram was parking in the middle of the track.
  3. Power on Floor site is OK.
  4. Soil CO2 profile worked well, but no power on the fences. Didn’t find broken wire‌
  5. dendrometer, soil moisture, and spectrume were measured. Dendrometers need reset because some have been out of range!!!

Vaira_Grass Site
  1. Fence and gate power: >12 v.
  2. Panel and Batteries: 14.0 v; 13.9 amps; 2.5 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time

9:39:56

Path/File name

D:\Data\V07_061.flx
D:\Data\VR070610930.raw


mean

std


mean

std

w

0.65

0.334

Ts

13.64

0.93

u

1.57

0.4

H2O

1.6

0.127

v

1.69

0.606

CO2

2.1

0.039




TC

0.43

0.051
  1. downloading data OK
  2. swaping Li-7500: remove #41, install #73
  3. clean up the surfaces of Delta PAR sensor, KZ PARs, 4-way radiation sensors.
  4. check CR23X: BUSY WITH COM.
  5. spectrometer measurement was taken by Youngryel.
  6. Closed gate and set up fence.

Tonzi_Tower Site

  1. Fence and gate power: >12 v.
  2. Panel and Batteries: 13.3 v; 0.0 amps; 5.8 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time


Path/File name

D:\Data\T07_061 .flx
D:\Data\TW07061.raw


mean

std


mean

std

w

-0.37

0.04

Ts

15.9

0.21

u

4.24

1.206

H2O

1.695

0.018

v

-1.0

1.539

CO2

2.704

0.054
  1. downloading data OK
  2. swaping Li-7500: remove #065, install #0976.
  3. check the fans of air temp. and relative humidity sensors on the tower and the floor.
  4. Check calibration cylinders;

CO2 900 psig; flow 18 psi.
N2 1200 psig; flow 20 psi.
Manually calibrate Li-800. Following Ted’s instruction: H:\IoneSavanna_2004\Tower_2004\CO2Profile\LI800_Calibration_Procedure_2Nov04.txt
Is the pump running‌ OK
  1. close gate and set up fence. OK

Toniz_Floor Site
  1. Fence and gate power: 12 v.
  2. Panel and Batteries: 13.7 v; 10.4 amps; 1.8 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time

11:53:39

Path/File name

D:\Data\F06_ 061 .flx
D:\Data\FL0761 .raw


mean

std


mean

std

w

1.0

0.545

Ts

15.8

0.804

u

1.9

0.945

H2O

1.9

0.117

v

1.2

0.620

CO2

2.03

0.07
  1. downloading data: OK
  2. Check MD-9 system connections: OK

CR23X3 – floor-Met
CR23X5 – soil CO2 profile
CR23X6 – tower-Met
CR10X2 – floor-Met
CR10X4 – sap-flow
CR10X7 – CO2 profile
CR10X8 – wind profile
CR1021 – Xingyuan’s sap flow
  1. Soil CO2 profile

Reading from datalogger

Panel temp

19.9



Battery voltage

13.5



CO2E_1

1171.3

TCE_1

15.0

CO2W_1

648

TCW_1

13.3

CO2E_2

1764

TCE_2

16.6

CO2W_2

927

TCW_2

11.0

CO2E_3

1720

TCE_3

11.6

CO2W_3

2839

TCW_3

11.3

CO2E_4

1981

TCE_4

9.3

CO2W_4

4251

TCW_4

11.6
  1. soil moisture (TDR)

tonzi

7931AFE

402165

574B4B

402FF3

574632

7A432E

7A3C6E

7A3B40

7A4AAA

2-Mar-07

61










SM









0-15

40.8

34.2

44.8

29.4

38.1

35.1

28.3

26.0

20.5

15-30

43.5

40.8

40.9

40.1

41.1

33.4

29.7

33.9

20.8

30-45

39.7

43.8

43.4

43.2

49.3

36.0

32.4

34.2

35.4

45-60

43.4

62.1

57.2

45.0

40.4

35.6

45.0

46.6

32.8












A6D882B

A3D04E8

A6D72F5

















0-15

38.7

34.2

24.1







15-30

26.0

32.1

34.9







30-45

36.0

36.4

37.3







45-60

43.6

49.9

49.6

















vaira

57318a

7933dee








0-15

24.2

28.4








15-30

28.7

32.3








30-45

31.8

32.4








45-60

33.6

38.0








  1. Close gate and set up fence.

Tonzi




Dendrometer







Date

Day

Tag #

Reading (cm)

3/2/2007

61

71

23.9



72

23.5



77

Broken



78

Broken



79

23.5



245

22.7



248

Out of range



250

21.9



255

22.4



‌252‌

missing



102

Broken

Field Data

No tank data

No TZ Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

No TZ Tree DBH found

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Explore the graph:Tonzi Tower Met: Temperature and Power in a new window

Explore the graph:Tonzi Tower Met: Solar Radiation in a new window

Explore the graph:Tonzi Tower Met: IRT Sensors in a new window

Explore the graph:LED Sensor Incoming in a new window

Explore the graph:LED Sensor Outgoing in a new window

Explore the graph:4-Band Solar Radiation in a new window

Explore the graph:Air Temperature Profile in a new window

Explore the graph:Relativity Humidity Profile in a new window

Explore the graph:Tonzi Tower PRI in a new window

Explore the graph:SRS PRI/NDVI in a new window

Explore the graph:SRS NDVI in a new window

No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found

Explore the graph:Tonzi PPT in a new window

Explore the graph:Tonzi CO2 and H2O Densities in a new window

Explore the graph:Air Pressure in a new window

No data found for TZ_fflux.
8 TZ_fmet graphs found

Explore the graph:Soil Heat Flux in a new window

Explore the graph:Tonzi Soil Temperature Set A in a new window

Explore the graph:Tonzi Soil Temperatures Set B in a new window

Explore the graph:Tonzi Soil Temperatures Set C in a new window

Explore the graph:Tonzi Soil Temperature Set D in a new window

Explore the graph:Well Level in a new window

Explore the graph:Well Water Temperature in a new window

Explore the graph:Soil Water Potential in a new window

No data found for TZ_tram.
3 TZ_co2prof graphs found

Explore the graph:Tower CO2 Profile Concentrations in a new window

Explore the graph:Tower CO2 Profile Cell Pressure in a new window

Explore the graph:CO2 Profile Sensor Temperature in a new window

No data found for TZ_irt.
1 TZ_windprof graphs found

Explore the graph:Wind Speed Profile in a new window

No data found for TZ_tflux.
2 TZ_sm graphs found

Explore the graph:Floor Solar Radiations in a new window

Explore the graph:TZ Soil Moisture in a new window

Can't check TZ_met
1 TZ_met graphs found

Explore the graph:Floor and Tower RH in a new window

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration