Equipment and Calibration History

View Equipment |

View history entry 5021 for Texas Electronics TR-525M sn: 50229-112

Date: 2020-12-03
From: East End - Precipitation
To: East End - Precipitation
Title: Tested
Notes: Plugged tipping bucket into the calibration CR23x and dripped 475ml of water through the bucket (1/2 of the bottle at a time) which should result in 100 tips. Got 110 tips. Did not adjust - will retest with better water metering system.
Entered by: Daphne Szutu